29 | 29 | The DTC (Device Type Code) is stored at holding register 30000 and uniquely identifies |
30 | 30 | the inverter model. The integration reads this at startup for automatic model detection. |
31 | 31 |
|
32 | | -| DTC Code | Model | |
33 | | -| --- | --- | |
34 | | -| 3502 | SPH 3000-6000TL BL | |
35 | | -| 3503 | SPH 3000-6000TL HU | |
36 | | -| 3504 | SPH 3000-6000TL HUB | |
37 | | -| 3601 | SPH 4000-10000TL3 BH-UP | |
38 | | -| 3701 | SPA 1000-3000TL BL | |
39 | | -| 3715 | SPA 3000-6000TL AU | |
40 | | -| 3716 | SPA 3000-6000TL AUB | |
41 | | -| 3725 | SPA 4000-10000TL3 BH-UP | |
42 | | -| 3735 | SPA 3000-6000TL BL | |
43 | | -| 5001 | MID 17–25KTL3-X / MID 20–30KTL3-X2 | |
44 | | -| 5002 | MID 33–36KTL3-X(Pro.E) / MOD 3–15KTL3-X | |
45 | | -| 5003 | MAC 30–70KTL3-X | |
46 | | -| 5100 | MIN 2500-6000TL-XH/XH(P) | |
47 | | -| 5200 | MIC/MIN 2500-6000TL-X/X2 | |
48 | | -| 5201 | MIN 7000-10000TL-X/X2 | |
49 | | -| 5400 | MOD-XH / MID-XH | |
50 | | -| 5600 | WIS 100K-AM; WIT 50–100K-H/HE/HU/A/AE/AU; WIT 50–100K-H/HE/HU/A/AE/AU-US; WIT 28–55K-H/HE/HU/A/AE/AU-US L2 | |
51 | | -| 5601 | WIT 29.9–50K-XHU (commercial hybrid with battery — confirmed via hardware scan Issue #338) | |
52 | | -| 5800 | WIS 210K | |
53 | | -| 5801 | WIS 215K-AM | |
| 32 | +This table is generated from `DTC_REGISTRY` in `auto_detection.py`, the single source of |
| 33 | +truth, and is checked against it by the test suite. |
| 34 | + |
| 35 | +**Profile mapping** is a separate question from the DTC itself. The code is read from the |
| 36 | +device and identifies the model reliably; whether the profile it selects is *correct* for |
| 37 | +that model has, for most entries, never been verified against hardware. See |
| 38 | +[DTC Debugging](../troubleshooting/dtc-debugging.md) for what that means in practice. |
| 39 | + |
| 40 | +| DTC Code | Model | Profile mapping | |
| 41 | +| --- | --- | --- | |
| 42 | +| 3501 | SPH 3000-6000TL BL | ⚠️ Unconfirmed | |
| 43 | +| 3502 | SPH 3000-6000TL BL-UP | ✅ Confirmed | |
| 44 | +| 3503 | SPH 3000-6000TL HU | ⚠️ Unconfirmed | |
| 45 | +| 3504 | SPH 3000-6000TL HUB | ✅ Confirmed | |
| 46 | +| 3601 | SPH-TL3 4-10kW | ✅ Confirmed | |
| 47 | +| 3701 | SPA 1000-3000TL BL | ⚠️ Unconfirmed | |
| 48 | +| 3715 | SPA 3000-6000TL AU | ⚠️ Unconfirmed | |
| 49 | +| 3716 | SPA 3000-6000TL AUB | ⚠️ Unconfirmed | |
| 50 | +| 3725 | SPA-TL3 4-10kW | ⚠️ Unconfirmed | |
| 51 | +| 3735 | SPA 3000TL BL-UP | ⚠️ Unconfirmed | |
| 52 | +| 5001 | MID 17-25KTL3-X; MID 20-30KTL3-X2; MID 25-30KTL3-X2 Pro/X2 Pro.E; MID 33-50KTL3-X2/X2 Pro/X2 Pro.E; MID 30-40KTL3-X | ✅ Confirmed | |
| 53 | +| 5002 | MID 33-36KTL3-X(Pro.E); MID 3-33KTL3-X3; MOD 3-15KTL3-X; MOD 3-15KTL3-X2(Pro); MOD 12-20KTL3-X2; MOD 12-20KTL3-X2(E); MOD 3-33KTL3-X3 | ⚠️ Unconfirmed | |
| 54 | +| 5003 | MAC 30-70KTL3-X; MAC 15-36KTL3-XL; MAC 50-70KTL3-X2; MAC 30-36KTL3-XL2 | ⚠️ Unconfirmed | |
| 55 | +| 5000 | MAX 50-100KTL3 LV/MV | ⚠️ Unconfirmed | |
| 56 | +| 5500 | MAX 175-253KTL3-X HV | ⚠️ Unconfirmed | |
| 57 | +| 5501 | MAX 80-150KTL3-X LV/MV; MAX 100-150KYL3-X2 LV/MV | ⚠️ Unconfirmed | |
| 58 | +| 5502 | MAX 320-350KTL3-X | ⚠️ Unconfirmed | |
| 59 | +| 5100 | MIN 2500-6000TL-XH/XH2/XHE/XA | ✅ Confirmed | |
| 60 | +| 5200 | MIC 600-3300TL-X/X2/X2(Pro); MIN 2500-6000TL-X/X2/X2(Pro)/X2(Pro.E) | ⚠️ Unconfirmed | |
| 61 | +| 5201 | MIN 7-10KTL-X/X2/X2(E) | ✅ Confirmed | |
| 62 | +| 5400 | MOD 3-10KTL3-XH/BP; MID 11-30KTL3-XH; MID 8-15KTL3-XHL/JP | ✅ Confirmed | |
| 63 | +| 5401 | MOD 3-15KTL3-HU; MID 33-50KTL3-HU | ✅ Confirmed | |
| 64 | +| 5600 | WIS 100K-AM; WIT 50-100K-H/HE/HU/A/AE/AU (incl. -US); WIT 28-55K-H/HE/HU/A/AE/AU-US L2 | ⚠️ Unconfirmed | |
| 65 | +| 5601 | WIT 29.9-50K-XHU | ✅ Confirmed | |
| 66 | +| 5800 | WIS 210K | ⚠️ Unconfirmed | |
| 67 | +| 5801 | WIS 215K-AM | ⚠️ Unconfirmed | |
| 68 | + |
| 69 | +### Not in the spec table |
| 70 | + |
| 71 | +| DTC Code | Model | Profile mapping | |
| 72 | +| --- | --- | --- | |
| 73 | +| 5603 | WIT 4-15kW Hybrid | ✅ Confirmed | |
54 | 74 |
|
55 | | -| 5603 | WIT 4–15KTL3 (residential three-phase hybrid) — confirmed via live register read by community contributor (Issue #335); absent from V2.03 spec DTC table but follows V2.03 protocol structure | |
| 75 | +> **WIT residential models (4-15KTL3):** The VPP V2.03 spec (dated 2025.9.1) does **not** include the WIT 4-15KTL3 residential series in its DTC table — only commercial WIT (50K-100K) models appear. DTC 5603 was confirmed by a live register read (register 30000 = 5603 on a WIT 15KTL3, Issue #335) with protocol version register 30099 = 203, so the residential range follows V2.03 register structure despite being omitted from the spec's device table. |
56 | 76 |
|
57 | | -> **WIT residential models (4–15KTL3):** The VPP V2.03 spec (dated 2025.9.1) does **not** include the WIT 4–15KTL3 residential series in its DTC table. Only commercial WIT (50K–100K) models appear. DTC 5603 has been confirmed via live hardware register read (register 30000 = 5603 on a WIT 15KTL3) and protocol version register 30099 = 203 (V2.03), confirming the residential range follows V2.03 register structure despite the omission from the spec's device table. |
| 77 | +**Non-VPP models** are not listed here. Legacy V1.39 devices (MIC 2500-5500MTL-S, TL3-S, SPH/SPM 8000-10000TL-HU), off-grid SPF (3400-3403) and SPE (64541) carry their DTC at holding register **43** rather than 30000. They appear in the [full DTC reference](../troubleshooting/dtc-debugging.md). |
58 | 78 |
|
59 | 79 | --- |
60 | 80 |
|
|
0 commit comments