Skip to content

Commit 01272af

Browse files
authored
Update mainboard.md
1 parent 6a90bc8 commit 01272af

File tree

1 file changed

+13
-10
lines changed

1 file changed

+13
-10
lines changed

docs/hardware/mainboard.md

Lines changed: 13 additions & 10 deletions
Original file line numberDiff line numberDiff line change
@@ -10,11 +10,6 @@
1010

1111
The stock mainboard of both the **Go** and the **Neo** is the "TriGorilla V_3.0.6" - it's the same board, it's just flashed with the respective firmware of either model.
1212

13-
??? info "TriGorilla V_3.0.7 Has Been Spotted"
14-
15-
User [zimmystor](https://www.reddit.com/user/zimmystor/) reported that at his Go a TriGorilla V_3.0.7 is being used. Besides a missing connector there doesn't seem to be any further differences to the V_3.0.6 board though.
16-
![TG v3.0.7](../assets/images/mainboard_mobo-GEN307_web.jpeg)
17-
1813
It is a 32bit 24V mainboard with a Huada HC32F460 KCTA ARM Cortex-M4 with 192KB SRAM and 512KB Flash.
1914
The speed of the ARM chip is listed as 200MHz by the manufacturer.
2015
It offers a microSD card reader, a USB-C connector and a 10 pin connector for adding the control unit.
@@ -45,13 +40,13 @@ The microSD card reader slot and the USB-C connector can be accessed from at fro
4540

4641

4742

48-
!!! danger "Add Ferrules To The 24V Wires!"
43+
??? danger "Add Ferrules To The 24V Wires!"
4944

5045
**It's highly advisable to cut off the soldered tips of the wires without a plug (power supply and heated bed) and add ferrules to them.**
5146

5247
When you are screwing down the soldered tip inside the clamp, the solder will get cracked a bit and may get deformed a bit as well. When the wire gets warm due to the current and the solder gets softer, the contact may become loose which could lead to malfunction or even cause fire in the last consequence. So it's always a good idea to just use proper ferrules. <br> ![Ferrules instead of soldered tips](../assets/images/mainboard_ferrules_web.jpg)
5348

54-
!!! danger "Avoid Short Circuits!"
49+
??? danger "Avoid Short Circuits!"
5550

5651
*Short circuits coming from the cartridge heater for example can/will damage your mainboard, so be careful to never cause a short circuit somehow!*
5752

@@ -61,7 +56,7 @@ The microSD card reader slot and the USB-C connector can be accessed from at fro
6156

6257
*So always turn off the whole printer first to avoid a short circuit which will destroy your mainboard!*
6358

64-
!!! warning "Use A USB Power Blocker"
59+
??? warning "Use A USB Power Blocker"
6560

6661
When connecting the printer to a computer or a Raspberry Pi, it is highly recommended to use an additional USB power blocker.
6762
By doing so, you make sure that neither the computer nor the mainboard will draw power through the USB-C connector from the other device. If you don't do so, it can harm your mainboard as well as your computer.
@@ -98,6 +93,14 @@ The microSD card reader slot and the USB-C connector can be accessed from at fro
9893
- As both the **Go** and the **Neo** use the same mainboard, you can just get yourself the mainboard for the **Go** if you e.g. own a **Neo** and can't get a mainboard for it (at the time of writing this, Anycubic only offers the mainboard for the **Go** in their shop) or if you find a seller but he charges more for the **Neo** version. You just need to flash the specific firmware for the **Neo** before using the printer.
9994

10095

96+
---
97+
98+
## TriGorilla V_3.0.7
99+
100+
User [zimmystor](https://www.reddit.com/user/zimmystor/) reported that at his Kobra Go a TriGorilla V_3.0.7 is being used. Besides a missing connector it's not clear what has been changed compared to the V_3.0.6 board - it seems that the MCU and pin assignments are the same though.
101+
102+
![TG v3.0.7](../assets/images/mainboard_mobo-GEN307_web.jpeg)
103+
101104
---
102105

103106
### Mainboard Cooling Fan
@@ -151,11 +154,11 @@ If you're using this kind (or a different kind) of MOSFET, you should check if t
151154
![MOSFET disassembled](../assets/images/PSU_MOSFET_disassembled_web.jpg)
152155

153156

154-
!!! warning "Mind The Polarity"
157+
??? warning "Mind The Polarity"
155158

156159
Pay attention to the polarity when connecting the components!
157160

158-
!!! warning "Add An Additional Fuse"
161+
??? warning "Add An Additional Fuse"
159162

160163
It is highly recommended to add a suitable fuse to the 24V line, right after the connector of the PSU. If your additional parts like the converter will fail, the fuse will melt - which can save you from burning down your house.
161164

0 commit comments

Comments
 (0)