forked from project-chip/connectedhomeip
-
Notifications
You must be signed in to change notification settings - Fork 4
Expand file tree
/
Copy pathTest_TC_BINFO_2_1.yaml
More file actions
685 lines (605 loc) · 19.9 KB
/
Copy pathTest_TC_BINFO_2_1.yaml
File metadata and controls
685 lines (605 loc) · 19.9 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
# Copyright (c) 2021 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# Auto-generated scripts for harness use only, please review before automation. The endpoints and cluster names are currently set to default
name: 11.2.1. [TC-BINFO-2.1] Attributes [DUT-Server]
PICS:
- BINFO.S
config:
nodeId: 0x12344321
cluster: "Basic"
endpoint: 0
tests:
- label: "Wait for the commissioned device to be retrieved"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
#not supported in YAML
- label:
"During Commissioning, TH Saves the CountryCode Information from
SetRegulatoryConfig command"
verification: |
While commissioning TH Saves the CountryCode Information from SetRegulatoryConfig command
./chip-tool pairing ble-wifi 1 GRLPrivate_EXT matter123 20202021 3840
TH END:
[1641381202.376419][5628:5633] CHIP:CTL: Received success response 0x3df8
sudo ./all-clusters-app --wifi
DUT END:
[1641381202.306840][4431:4431] CHIP:DL: NVS set: chip-config/regulatory-location = 0 (0x0)
After pairing, Verify the countrycode Information by reading location atrribute from TH to DUT.
./chip-tool basic read location 1 0
On TH, Verify that TH reads Location from the DUT successfully, the name should be string and length is less than or equal to 2 bytes.
[1656495999.760797][2249:2254] CHIP:DMG: }
[1656495999.761084][2249:2254] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_0028 Attribute 0x0000_0006 DataVersion: 941124320
[1656495999.761187][2249:2254] CHIP:TOO: Location: XX
[1656495999.761371][2249:2254] CHIP:EM: Sending Standalone Ack for MessageCounter:7663506 on exchange 28126i
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH reads DataModelRevision from the DUT."
PICS: BINFO.S.A0000
command: "readAttribute"
attribute: "DataModelRevision"
response:
saveAs: DataModelRevisionValue
constraints:
type: int16u
minValue: 0
maxValue: 65534
- label: "TH writes DataModelRevision from the DUT."
PICS: BINFO.S.A0000
command: "writeAttribute"
attribute: "DataModelRevision"
arguments:
value: 4388
response:
error: UNSUPPORTED_WRITE
- label: "TH reads DataModelRevision from the DUT."
PICS: BINFO.S.A0000
command: "readAttribute"
attribute: "DataModelRevision"
response:
value: DataModelRevisionValue
- label: "TH reads VendorName from the DUT."
PICS: BINFO.S.A0001
command: "readAttribute"
attribute: "VendorName"
response:
saveAs: VendorNameValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes VendorName from the DUT."
PICS: BINFO.S.A0001
command: "writeAttribute"
attribute: "VendorName"
arguments:
value: "sample"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads VendorName from the DUT."
PICS: BINFO.S.A0001
command: "readAttribute"
attribute: "VendorName"
response:
value: VendorNameValue
- label: "TH reads VendorID from the DUT."
PICS: BINFO.S.A0002
command: "readAttribute"
attribute: "VendorID"
response:
saveAs: VendorIDValue
constraints:
type: vendor_id
minValue: 1
maxValue: 65521
- label:
"Verify that VendorID matches the value assigned to this manufacturer"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A0002
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes VendorID from the DUT."
PICS: BINFO.S.A0002
command: "writeAttribute"
attribute: "VendorID"
arguments:
value: 17
response:
error: UNSUPPORTED_WRITE
- label: "TH reads VendorID from the DUT."
PICS: BINFO.S.A0002
command: "readAttribute"
attribute: "VendorID"
response:
value: VendorIDValue
- label: "TH reads ProductName from the DUT"
PICS: BINFO.S.A0003
command: "readAttribute"
attribute: "ProductName"
response:
saveAs: ProductNameValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes ProductName from the DUT."
PICS: BINFO.S.A0003
command: "writeAttribute"
attribute: "ProductName"
arguments:
value: "newproduct"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductName from the DUT"
PICS: BINFO.S.A0003
command: "readAttribute"
attribute: "ProductName"
response:
value: ProductNameValue
- label: "TH reads ProductID from the DUT."
PICS: BINFO.S.A0004
command: "readAttribute"
attribute: "ProductID"
response:
saveAs: ProductIDValue
constraints:
type: int16u
minValue: 1
maxValue: 65534
- label: "TH writes ProductID from the DUT."
PICS: BINFO.S.A0004
command: "writeAttribute"
attribute: "ProductID"
arguments:
value: 17697
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductID from the DUT."
PICS: BINFO.S.A0004
command: "readAttribute"
attribute: "ProductID"
response:
value: ProductIDValue
- label: "TH reads NodeLabel from the DUT"
PICS: BINFO.S.A0005
command: "readAttribute"
attribute: "NodeLabel"
response:
saveAs: NodeLabelValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes NodeLabel from the DUT."
PICS: BINFO.S.A0005
command: "writeAttribute"
attribute: "NodeLabel"
arguments:
value: "newnode"
- label: "TH reads NodeLabel from the DUT"
PICS: BINFO.S.A0005
command: "readAttribute"
attribute: "NodeLabel"
response:
value: "newnode"
- label: "TH reads Location from the DUT."
PICS: BINFO.S.A0006
command: "readAttribute"
attribute: "Location"
response:
constraints:
type: char_string
maxLength: 16
- label:
"Verify that the Location is same as CountryCode value saved from
step1"
verification: |
./chip-tool basic read location 1 0
On TH, Verify that TH reads Location from the DUT successfully, the name should be string and length is less than or equal to 2 bytes.
[1656495999.760797][2249:2254] CHIP:DMG: }
[1656495999.761084][2249:2254] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_0028 Attribute 0x0000_0006 DataVersion: 941124320
[1656495999.761187][2249:2254] CHIP:TOO: Location: XX
[1656495999.761371][2249:2254] CHIP:EM: Sending Standalone Ack for MessageCounter:7663506 on exchange 28126i
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A0006
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH write Location from the DUT"
PICS: BINFO.S.A0006
command: "writeAttribute"
attribute: "Location"
arguments:
value: "in"
- label: "TH reads Location from the DUT."
PICS: BINFO.S.A0006
command: "readAttribute"
attribute: "Location"
response:
value: "in"
- label: "TH reads HardwareVersion from the DUT"
PICS: BINFO.S.A0007
command: "readAttribute"
attribute: "HardwareVersion"
response:
saveAs: HardwareVersionValue
constraints:
type: int16u
minValue: 0
maxValue: 65534
- label: "TH writes HardwareVersion from the DUT."
PICS: BINFO.S.A0007
command: "writeAttribute"
attribute: "HardwareVersion"
arguments:
value: 17713
response:
error: UNSUPPORTED_WRITE
- label: "TH reads HardwareVersion from the DUT"
PICS: BINFO.S.A0007
command: "readAttribute"
attribute: "HardwareVersion"
response:
value: HardwareVersionValue
- label: "TH reads HardwareVersionString from the DUT."
PICS: BINFO.S.A0008
command: "readAttribute"
attribute: "HardwareVersionString"
response:
saveAs: HardwareVersionStringValue
constraints:
type: char_string
minLength: 1
maxLength: 64
- label: "TH writes HardwareVersionString from the DUT."
PICS: BINFO.S.A0008
command: "writeAttribute"
attribute: "HardwareVersionString"
arguments:
value: "newhardwareversion"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads HardwareVersionString from the DUT."
PICS: BINFO.S.A0008
command: "readAttribute"
attribute: "HardwareVersionString"
response:
value: HardwareVersionStringValue
- label: "TH reads SoftwareVersion from the DUT"
PICS: BINFO.S.A0009
command: "readAttribute"
attribute: "SoftwareVersion"
response:
saveAs: SoftwareVersionValue
constraints:
minValue: 0
maxValue: 4294967294
- label:
"Verify that the SoftwareVersion is not displayed to the end-user
through any device specific means (ex: screen, audio)"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A0009
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes SoftwareVersion from the DUT."
PICS: BINFO.S.A0009
command: "writeAttribute"
attribute: "SoftwareVersion"
arguments:
value: 33299
response:
error: UNSUPPORTED_WRITE
- label: "TH reads SoftwareVersion from the DUT"
PICS: BINFO.S.A0009
command: "readAttribute"
attribute: "SoftwareVersion"
response:
value: SoftwareVersionValue
- label: "TH reads SoftwareVersionString from the DUT"
PICS: BINFO.S.A000a
command: "readAttribute"
attribute: "SoftwareVersionString"
response:
saveAs: SoftwareVersionStringValue
constraints:
minLength: 1
maxLength: 64
- label: "TH writes SoftwareVersionString from the DUT."
PICS: BINFO.S.A000a
command: "writeAttribute"
attribute: "SoftwareVersionString"
arguments:
value: "1.0"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads SoftwareVersionString from the DUT"
PICS: BINFO.S.A000a
command: "readAttribute"
attribute: "SoftwareVersionString"
response:
value: SoftwareVersionStringValue
- label: "TH reads ManufacturingDate from the DUT."
PICS: BINFO.S.A000b
command: "readAttribute"
attribute: "ManufacturingDate"
response:
saveAs: ManufacturingDateValue
constraints:
type: char_string
minLength: 8
maxLength: 16
- label:
"Verify if the first 8 characters specify date according to ISO 8601,
i.e, YYYYMMDD"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A000b
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes ManufacturingDate from the DUT."
PICS: BINFO.S.A000b
command: "writeAttribute"
attribute: "ManufacturingDate"
arguments:
value: "20210814789452IN"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ManufacturingDate from the DUT."
PICS: BINFO.S.A000b
command: "readAttribute"
attribute: "ManufacturingDate"
response:
value: ManufacturingDateValue
- label: "TH reads PartNumber from the DUT"
PICS: BINFO.S.A000c && PART_NUM
command: "readAttribute"
attribute: "PartNumber"
response:
saveAs: PartNumberValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes PartNumber from the DUT."
PICS: BINFO.S.A000c
command: "writeAttribute"
attribute: "PartNumber"
arguments:
value: "newpart"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads PartNumber from the DUT"
PICS: BINFO.S.A000c && PART_NUM
command: "readAttribute"
attribute: "PartNumber"
response:
value: PartNumberValue
- label: "TH reads ProductURL from the DUT"
PICS: BINFO.S.A000d
command: "readAttribute"
attribute: "ProductURL"
response:
saveAs: ProductURLValue
constraints:
type: long_char_string
maxLength: 256
- label:
"Verify that it specifies a link to a specific web page, Verify that
it follows the syntax rules specified in RFC 3986."
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A000d
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes ProductURL from the DUT."
PICS: BINFO.S.A000d
command: "writeAttribute"
attribute: "ProductURL"
arguments:
value: "https://www.example.com"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductURL from the DUT"
PICS: BINFO.S.A000d
command: "readAttribute"
attribute: "ProductURL"
response:
value: ProductURLValue
- label: "TH reads ProductLabel from the DUT."
PICS: BINFO.S.A000e
command: "readAttribute"
attribute: "ProductLabel"
response:
saveAs: ProductLabelValue
constraints:
type: char_string
maxLength: 64
- label:
"Verify that it does not include the name of the vendor as defined
within the VendorName attribute"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A000e
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes ProductLabel from the DUT."
PICS: BINFO.S.A000e
command: "writeAttribute"
attribute: "ProductLabel"
arguments:
value: "newproductlabel"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductLabel from the DUT."
PICS: BINFO.S.A000e
command: "readAttribute"
attribute: "ProductLabel"
response:
value: ProductLabelValue
- label: "TH reads SerialNumber from the DUT."
PICS: BINFO.S.A000f
command: "readAttribute"
attribute: "SerialNumber"
response:
saveAs: SerialNumberValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes SerialNumber from the DUT."
PICS: BINFO.S.A000f
command: "writeAttribute"
attribute: "SerialNumber"
arguments:
value: "newserialnumber"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads SerialNumber from the DUT."
PICS: BINFO.S.A000f
command: "readAttribute"
attribute: "SerialNumber"
response:
value: SerialNumberValue
- label: "TH reads LocalConfigDisabled from the DUT."
PICS: BINFO.S.A0010
command: "readAttribute"
attribute: "LocalConfigDisabled"
response:
value: false
constraints:
type: boolean
- label: "TH sets LocalConfigDisabled to True"
PICS: BINFO.S.A0010
command: "writeAttribute"
attribute: "LocalConfigDisabled"
arguments:
value: true
- label: "TH reads LocalConfigDisabled from the DUT."
PICS: BINFO.S.A0010
command: "readAttribute"
attribute: "LocalConfigDisabled"
response:
value: true
- label: "TH reads Reachable from the DUT."
PICS: BINFO.S.A0011
command: "readAttribute"
attribute: "Reachable"
response:
value: true
constraints:
type: boolean
- label:
"TH sends Write request message to DUT to change value of Reachable to
false"
PICS: BINFO.S.A0011
command: "writeAttribute"
attribute: "Reachable"
arguments:
value: false
response:
error: UNSUPPORTED_WRITE
- label: "TH reads Reachable from the DUT."
PICS: BINFO.S.A0011
command: "readAttribute"
attribute: "Reachable"
response:
value: true
constraints:
type: boolean
- label: "TH reads UniqueID from the DUT."
PICS: BINFO.S.A0012
command: "readAttribute"
attribute: "UniqueID"
response:
saveAs: UniqueIDValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes UniqueID from the DUT."
PICS: BINFO.S.A0012
command: "writeAttribute"
attribute: "UniqueID"
arguments:
value: "newid"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads UniqueID from the DUT."
PICS: BINFO.S.A0012
command: "readAttribute"
attribute: "UniqueID"
response:
value: UniqueIDValue
- label: "TH reads CapabilityMinima attribute from the DUT."
PICS: BINFO.S.A0013
command: "readAttribute"
attribute: "CapabilityMinima"
response:
saveAs: CapabilityMinimaValue
- label:
"Step 56 is implicitly validating the attribute(CapabilityMinima)
constraints, as long as the payload is being parsed successfully"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BINFO.S.A0013
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes CapabilityMinima from the DUT."
PICS: BINFO.S.A0013
command: "writeAttribute"
attribute: "CapabilityMinima"
arguments:
value: { "CaseSessionsPerFabric": 4, "SubscriptionsPerFabric": 4 }
response:
error: UNSUPPORTED_WRITE
- label: "TH reads CapabilityMinima attribute from the DUT."
PICS: BINFO.S.A0013
command: "readAttribute"
attribute: "CapabilityMinima"
response:
value: CapabilityMinimaValue