Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathmodbus_process_analyzer.py
More file actions
316 lines (259 loc) · 12.7 KB
/
Copy pathmodbus_process_analyzer.py
File metadata and controls
316 lines (259 loc) · 12.7 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
#!/usr/bin/env python3
"""
Modbus Process Analyzer
Repeatedly reads process values from a Modbus device and analyzes patterns
to determine what industrial process it likely controls
"""
import sys
import time
import statistics
from pymodbus.client.sync import ModbusTcpClient
from pymodbus.exceptions import ModbusException
def analyze_process_values(ip_address, samples=20, delay=1):
"""Read process values from a Modbus device and analyze patterns"""
print(f"Analyzing process values from Modbus device at {ip_address}...")
print(f"Collecting {samples} samples with {delay} second delay...")
client = ModbusTcpClient(ip_address, port=502)
try:
client.connect()
# Arrays to store collected data
holding_registers = []
input_registers = []
discrete_inputs = []
coils = []
# Collect data samples
for i in range(samples):
sys.stdout.write(f"\rCollecting sample {i+1}/{samples}...")
sys.stdout.flush()
# Read holding registers (function code 3)
try:
response = client.read_holding_registers(0, 20, unit=1)
if not response.isError():
holding_registers.append(response.registers)
except Exception:
pass
# Read input registers (function code 4)
try:
response = client.read_input_registers(0, 20, unit=1)
if not response.isError():
input_registers.append(response.registers)
except Exception:
pass
# Read discrete inputs (function code 2)
try:
response = client.read_discrete_inputs(0, 20, unit=1)
if not response.isError():
discrete_inputs.append(response.bits)
except Exception:
pass
# Read coils (function code 1)
try:
response = client.read_coils(0, 20, unit=1)
if not response.isError():
coils.append(response.bits)
except Exception:
pass
time.sleep(delay)
print("\nAnalysis complete!")
# Analyze collected data
print("\n===== PROCESS ANALYSIS =====")
# Analyze holding registers (usually process setpoints)
if holding_registers:
print("\nHolding Registers Analysis (Process Setpoints):")
analyze_register_patterns(holding_registers)
# Analyze input registers (usually process values)
if input_registers:
print("\nInput Registers Analysis (Process Values):")
analyze_register_patterns(input_registers)
# Analyze discrete inputs (usually digital sensor inputs)
if discrete_inputs:
print("\nDiscrete Inputs Analysis (Digital Sensors):")
analyze_boolean_patterns(discrete_inputs)
# Analyze coils (usually digital outputs/controls)
if coils:
print("\nCoils Analysis (Digital Outputs/Controls):")
analyze_boolean_patterns(coils)
# Infer process type based on patterns
print("\n===== PROCESS TYPE INFERENCE =====")
infer_process_type(holding_registers, input_registers, discrete_inputs, coils)
except ModbusException as e:
print(f"Modbus error: {e}")
except Exception as e:
print(f"Error: {e}")
finally:
client.close()
def analyze_register_patterns(register_samples):
"""Analyze patterns in register values"""
if not register_samples:
return
# Transpose data for per-register analysis
registers_by_address = list(zip(*register_samples))
for addr, values in enumerate(registers_by_address):
if not values:
continue
# Check if values are changing
if len(set(values)) == 1:
print(f" Register {addr}: Static value {values[0]} (configured parameter or unused)")
continue
# Calculate statistics
min_val = min(values)
max_val = max(values)
avg_val = sum(values) / len(values)
# Identify patterns
increasing = all(values[i] <= values[i+1] for i in range(len(values)-1))
decreasing = all(values[i] >= values[i+1] for i in range(len(values)-1))
fluctuating = not increasing and not decreasing
# Analyze value range
range_pct = ((max_val - min_val) / max(max_val, 1)) * 100
print(f" Register {addr}: Values range from {min_val} to {max_val} (avg: {avg_val:.2f})")
# Describe the pattern
if increasing:
print(f" Pattern: Steadily increasing (ramp up)")
elif decreasing:
print(f" Pattern: Steadily decreasing (ramp down)")
elif range_pct < 5:
print(f" Pattern: Small fluctuations (around setpoint)")
elif range_pct > 50:
print(f" Pattern: Large swings (on/off cycling)")
else:
print(f" Pattern: Normal process variations")
# Typical value ranges for various process types
if 0 <= min_val <= max_val <= 100:
print(f" Likely represents: Percentage value (valve position, motor speed)")
elif 15 <= min_val <= 30 and 15 <= max_val <= 30:
print(f" Likely represents: Ambient temperature (Celsius)")
elif 100 <= min_val <= 200 and 100 <= max_val <= 200:
print(f" Likely represents: Process temperature (Celsius)")
elif 1000 <= min_val <= 2000 and 1000 <= max_val <= 2000:
print(f" Likely represents: Pressure (PSI or kPa)")
elif 0 <= min_val <= 10 and 0 <= max_val <= 10:
print(f" Likely represents: Flow rate or level")
def analyze_boolean_patterns(boolean_samples):
"""Analyze patterns in boolean values"""
if not boolean_samples:
return
# Transpose data for per-bit analysis
bits_by_address = list(zip(*boolean_samples))
for addr, values in enumerate(bits_by_address):
if not values:
continue
# Check if values are changing
if len(set(values)) == 1:
status = "ON" if values[0] else "OFF"
print(f" Bit {addr}: Static {status} (configured parameter or unused)")
continue
# Count transitions
transitions = sum(1 for i in range(len(values)-1) if values[i] != values[i+1])
# Calculate percentage of time ON
pct_on = (sum(1 for v in values if v) / len(values)) * 100
print(f" Bit {addr}: ON {pct_on:.1f}% of the time, {transitions} transitions")
# Describe the pattern
if transitions == 1:
print(f" Pattern: Single state change")
elif transitions > len(values) * 0.4:
print(f" Pattern: Rapidly cycling (sensor feedback or alarm)")
elif pct_on > 90:
print(f" Pattern: Mostly ON with occasional OFF")
elif pct_on < 10:
print(f" Pattern: Mostly OFF with occasional ON")
else:
print(f" Pattern: Normal ON/OFF cycling")
def infer_process_type(holding_registers, input_registers, discrete_inputs, coils):
"""Infer the type of industrial process based on observed patterns"""
process_indicators = {
"temperature_control": 0,
"motor_control": 0,
"valve_control": 0,
"level_control": 0,
"pressure_control": 0,
"flow_control": 0,
"safety_system": 0
}
# Check for temperature control indicators
if holding_registers and input_registers:
# Simplistic detection: look for values between 15-250 in registers
for samples in [holding_registers, input_registers]:
for sample in samples:
for value in sample:
if 15 <= value <= 30: # Ambient temperature range
process_indicators["temperature_control"] += 1
elif 100 <= value <= 250: # Process temperature range
process_indicators["temperature_control"] += 2
# Check for motor control indicators
if holding_registers and input_registers:
# Motors often use percentage values for speed
for samples in [holding_registers, input_registers]:
for sample in samples:
if any(0 <= value <= 100 for value in sample):
process_indicators["motor_control"] += 1
# Check for valve control indicators
if coils:
# Valves often use coils for open/close control
process_indicators["valve_control"] += len(coils[0]) // 2
# Check for level control indicators
if input_registers:
# Level sensors often provide values in a fixed range
for sample in input_registers:
if any(0 <= value <= 100 for value in sample):
process_indicators["level_control"] += 1
# Check for pressure control indicators
if input_registers:
# Pressure values are often in the hundreds or thousands
for sample in input_registers:
if any(100 <= value <= 5000 for value in sample):
process_indicators["pressure_control"] += 1
# Check for flow control indicators
if input_registers:
# Flow values often change more rapidly than other measurements
registers_by_address = list(zip(*input_registers))
for values in registers_by_address:
if len(set(values)) > len(values) // 2:
process_indicators["flow_control"] += 1
# Check for safety system indicators
if discrete_inputs and coils:
# Safety systems often have many discrete I/O points
if len(discrete_inputs[0]) > 10 or len(coils[0]) > 10:
process_indicators["safety_system"] += 1
# Find the most likely process types
sorted_indicators = sorted(process_indicators.items(), key=lambda x: x[1], reverse=True)
print("Based on the observed data patterns, this device likely controls:")
if sorted_indicators[0][1] == 0:
print(" Unable to determine process type from available data")
return
# Print top process types
for process, score in sorted_indicators:
if score > 0 and score >= sorted_indicators[0][1] / 2:
if process == "temperature_control":
print(" A TEMPERATURE CONTROL process (heating/cooling system)")
print(" - This could be a furnace, oven, refrigeration, or HVAC system")
print(" - Critical for maintaining process conditions and product quality")
elif process == "motor_control":
print(" A MOTOR CONTROL process (conveyor, pump, fan)")
print(" - This could be controlling conveyors, mixers, or material handling")
print(" - Critical for material movement and processing")
elif process == "valve_control":
print(" A VALVE CONTROL process (fluid flow regulation)")
print(" - This could be controlling product flow, mixing, or batching")
print(" - Critical for process recipe compliance and quality control")
elif process == "level_control":
print(" A LEVEL CONTROL process (tank, hopper)")
print(" - This could be monitoring storage levels or feeding material")
print(" - Critical for preventing overflow/underflow conditions")
elif process == "pressure_control":
print(" A PRESSURE CONTROL process (vessel, pipeline)")
print(" - This could be regulating pressure in vessels or distribution systems")
print(" - Critical for process safety and product quality")
elif process == "flow_control":
print(" A FLOW CONTROL process (pipeline, distribution)")
print(" - This could be managing fluid or gas flow rates")
print(" - Critical for process timing and throughput")
elif process == "safety_system":
print(" A SAFETY SYSTEM (emergency shutdown, permissive)")
print(" - This appears to be monitoring safety conditions")
print(" - Critical for personnel and equipment protection")
if __name__ == "__main__":
if len(sys.argv) != 2:
print("Usage: python3 modbus_process_analyzer.py <ip_address>")
sys.exit(1)
ip_address = sys.argv[1]
analyze_process_values(ip_address)