1616
1717
1818from collections .abc import Callable , Sequence
19- from dataclasses import dataclass , field
2019from typing import (
2120 NotRequired ,
2221 TypedDict ,
4140 State ,
4241 StringByteTable ,
4342)
44-
45- TYPE_MAPPING = {
46- "1" : ("current" , "RMS" ),
47- "2" : ("peak" , "Peak" ),
48- "3" : ("unbalanced" , "Unbalanced" ),
49- "4" : ("voltage" , "RMS" ),
50- "5" : ("power" , "Active" ),
51- "6" : ("appower" , "Apparent" ),
52- # power factor is defined as the ratio of the real power flowing
53- # to the load to the apparent power
54- "7" : ("power_factor" , "Power Factor" ),
55- "8" : ("energy" , "Active" ),
56- "9" : ("energy" , "Apparent" ),
57- "10" : ("temp" , "" ),
58- "11" : ("humidity" , "" ),
59- "12" : ("airflow" , "" ),
60- "13" : ("pressure_pa" , "Air" ),
61- "14" : ("binary" , "On/Off" ),
62- "15" : ("binary" , "Trip" ),
63- "16" : ("binary" , "Vibration" ),
64- "17" : ("binary" , "Water Detector" ),
65- "18" : ("binary" , "Smoke Detector" ),
66- "19" : ("binary" , "" ),
67- "20" : ("binary" , "Contact" ),
68- "21" : ("fanspeed" , "" ),
69- "26" : ("residual_current" , "Residual Current" ),
70- "30" : ("" , "Other" ),
71- "31" : ("" , "None" ),
72- }
73-
74- UNIT_MAPPING = {
75- "-1" : "" ,
76- "0" : " Other" ,
77- "1" : " V" ,
78- "2" : " A" ,
79- "3" : " W" ,
80- "4" : " VA" ,
81- "5" : " Wh" ,
82- "6" : " VAh" ,
83- # for dev_unit in check_temperature
84- "7" : "c" ,
85- "8" : " hz" ,
86- "9" : "%" ,
87- "10" : " m/s" ,
88- "11" : " Pa" ,
89- # 1 psi = 6894,757293168 Pa
90- "12" : " psi" ,
91- "13" : " g" ,
92- # for dev_unit in check_temperature
93- "14" : "f" ,
94- "15" : " ft" ,
95- "16" : " inch" ,
96- "17" : " cm" ,
97- "18" : " m" ,
98- "19" : " RPM" ,
99- }
100-
101-
102- RESIDUAL_BITMASK = 0b01000000
43+ from cmk .plugins .raritan import (
44+ InletDeviceCapabilities ,
45+ InletPoleCapabilities ,
46+ InletSensorEnabledThresholds ,
47+ PDU ,
48+ RaritanData ,
49+ Sensor ,
50+ SensorValues ,
51+ TYPE_MAPPING ,
52+ UNIT_MAPPING ,
53+ )
10354
10455_RENDER_FUNCTION_AND_UNIT : dict [str , tuple [Callable | None , str ]] = {
10556 "%" : (
@@ -119,46 +70,6 @@ class Params(TypedDict):
11970 residual_levels : NotRequired [NoLevelsT | FixedLevelsT ]
12071
12172
122- @dataclass (frozen = True , kw_only = True )
123- class PDU :
124- pdu_index : str
125- label : str
126- name : str
127- plug : str
128- pole_count : str
129- rated_voltage : str
130- rated_current : str
131- rated_frequency : str
132- rated_va : str
133- plug_descriptor : str
134- enable_state : str
135- device_capabilities : list [int ]
136- pole_capabilities : list [int ]
137-
138-
139- @dataclass (frozen = True , kw_only = True )
140- class SensorValues :
141- sensor_value : float
142- sensor_upper_crit : float
143- sensor_upper_warn : float
144-
145-
146- @dataclass (frozen = True , kw_only = True )
147- class Sensor :
148- availability : str
149- sensor_name : str
150- sensor_type : str
151- sensor_values : SensorValues
152- sensor_unit : str
153- sensor_thresholds : list [int ]
154-
155-
156- @dataclass (kw_only = True )
157- class RaritanData :
158- pdu : PDU
159- sensors : dict [str , dict [str , Sensor ]] = field (default_factory = dict )
160-
161-
16273def _parse_pdu_data (raw_pdu_data : StringByteTable ) -> PDU :
16374 pdu_data = raw_pdu_data [0 ]
16475
@@ -172,8 +83,8 @@ def _parse_pdu_data(raw_pdu_data: StringByteTable) -> PDU:
17283 rated_current = str (pdu_data [6 ]),
17384 rated_frequency = str (pdu_data [7 ]),
17485 rated_va = str (pdu_data [8 ]),
175- device_capabilities = pdu_data [ 9 ] if isinstance (pdu_data [9 ], list ) else [ int ( pdu_data [ 9 ])] ,
176- pole_capabilities = pdu_data [ 10 ] if isinstance (pdu_data [10 ], list ) else [ int ( pdu_data [ 10 ])] ,
86+ device_capabilities = InletDeviceCapabilities . from_snmp_bits (pdu_data [9 ]) ,
87+ pole_capabilities = InletPoleCapabilities . from_snmp_bits (pdu_data [10 ]) ,
17788 plug_descriptor = str (pdu_data [11 ]),
17889 enable_state = str (pdu_data [12 ]),
17990 )
@@ -235,9 +146,7 @@ def _parse_sensor_data(sensor_data: StringByteTable) -> dict[str, dict[str, Sens
235146 decimal_digits_int ,
236147 ),
237148 sensor_unit = sensor_unit .strip (),
238- sensor_thresholds = enabled_thresholds
239- if isinstance (enabled_thresholds , list )
240- else [int (enabled_thresholds )],
149+ sensor_thresholds = InletSensorEnabledThresholds .from_snmp_bits (enabled_thresholds ),
241150 )
242151
243152 return sensors
@@ -250,9 +159,9 @@ def parse_raritan_inlet_sensors(
250159 return None
251160
252161 section = RaritanData (pdu = _parse_pdu_data (raw_pdu_data ))
253- if int ( section .pdu .device_capabilities [ 3 ]) & RESIDUAL_BITMASK :
162+ if section .pdu .device_capabilities . residualCurrent :
254163 section .sensors .update (_parse_sensor_data (string_table [1 ]))
255- if int ( section .pdu .pole_capabilities [ 3 ]) & RESIDUAL_BITMASK :
164+ if section .pdu .pole_capabilities . residualCurrent :
256165 section .sensors .update (_parse_sensor_data (string_table [2 ]))
257166
258167 return section
@@ -346,16 +255,25 @@ def _create_levels(
346255 params : Params ,
347256 sensor_data : Sensor ,
348257) -> NoLevelsT | FixedLevelsT :
349- thresholds = sensor_data .sensor_thresholds [0 ]
350- has_warn = thresholds & 0b00100000 and sensor_data .sensor_values .sensor_upper_warn != 0
351- has_crit = thresholds & 0b00010000 and sensor_data .sensor_values .sensor_upper_crit != 0
352258
353- if has_warn or has_crit :
354- levels_upper_warn = sensor_data .sensor_values .sensor_upper_warn if has_warn else None
355- levels_upper_crit = sensor_data .sensor_values .sensor_upper_crit if has_crit else None
356- return ("fixed" , (levels_upper_warn , levels_upper_crit ))
259+ has_warn = (
260+ sensor_data .sensor_thresholds .upperWarning
261+ and sensor_data .sensor_values .sensor_upper_warn != 0
262+ )
263+ has_crit = (
264+ sensor_data .sensor_thresholds .upperCritical
265+ and sensor_data .sensor_values .sensor_upper_crit != 0
266+ )
357267
358- return params .get ("residual_levels" , ("no_levels" , None ))
268+ if params .get ("residual_levels" , False ):
269+ levels_upper = params .get ("residual_levels" , ("no_levels" , None ))
270+ elif has_warn or has_crit :
271+ levels_upper_warn = sensor_data .sensor_values .sensor_upper_warn if has_warn else has_crit
272+ levels_upper_crit = sensor_data .sensor_values .sensor_upper_crit if has_crit else has_warn
273+ levels_upper = ("fixed" , (levels_upper_warn , levels_upper_crit ))
274+ else :
275+ levels_upper = ("no_levels" , None )
276+ return levels_upper
359277
360278
361279def _check_missing_levels (