Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathADC121C021.py
More file actions
executable file
·70 lines (58 loc) · 3.19 KB
/
Copy pathADC121C021.py
File metadata and controls
executable file
·70 lines (58 loc) · 3.19 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
# Distributed with a free-will license.
# Use it any way you want, profit or free, provided it fits in the licenses of its associated works.
# ADC121C021
# This code is designed to work with the ADC121C021_I2CADC I2C Mini Module available from ControlEverything.com.
# https://www.controleverything.com/content/Analog-Digital-Converters?sku=ADC121C021_I2CADC#tabs-0-product_tabset-2
import smbus
import time
# Get I2C bus
bus = smbus.SMBus(1)
# I2C address of the device
ADC121C021_DEFAULT_ADDRESS = 0x50
# ADC121C021 Register Map
ADC121C021_REG_CONVERSION = 0x00 # Conversion Result Register
ADC121C021_REG_ALERT_STATUS = 0x01 # Alert Status Register
ADC121C021_REG_CONFIG = 0x02 # Configuration Register
ADC121C021_REG_LOW_LIMIT = 0x03 # Alert Low Limit Register
ADC121C021_REG_HIGH_LIMIT = 0x04 # Alert High Limit Register
ADC121C021_REG_HYSTERESIS = 0x05 # Alert Hysteresis Register
ADC121C021_REG_LOWCONV = 0x06 # Lowest Conversion Register
ADC121C021_REG_HIGHCONV = 0x07 # Highest Conversion Register
# ADC121C021 Configuration Register
ADC121C021_CONFIG_CYCLE_TIME_DIS = 0x00 # Automatic Conversion Mode Disabled, 0 ksps
ADC121C021_CONFIG_CYCLE_TIME_32 = 0x20 # Tconvert x 32, 27 ksps
ADC121C021_CONFIG_CYCLE_TIME_64 = 0x40 # Tconvert x 64, 13.5 ksps
ADC121C021_CONFIG_CYCLE_TIME_128 = 0x60 # Tconvert x 128, 6.7 ksps
ADC121C021_CONFIG_CYCLE_TIME_256 = 0x80 # Tconvert x 256, 3.4 ksps
ADC121C021_CONFIG_CYCLE_TIME_512 = 0xA0 # Tconvert x 512, 1.7 ksps
ADC121C021_CONFIG_CYCLE_TIME_1024 = 0xC0 # Tconvert x 1024, 0.9 ksps
ADC121C021_CONFIG_CYCLE_TIME_2048 = 0xE0 # Tconvert x 2048, 0.4 ksps
ADC121C021_CONFIG_ALERT_HOLD_CLEAR = 0x00 # Alerts will self-clear
ADC121C021_CONFIG_ALERT_FLAG_NOCLEAR = 0x10 # Alerts will not self-clear
ADC121C021_CONFIG_ALERT_FLAG_DIS = 0x00 # Disables alert status bit in the Conversion Result register
ADC121C021_CONFIG_ALERT_FLAG_EN = 0x08 # Enables alert status bit in the Conversion Result register
ADC121C021_CONFIG_ALERT_PIN_DIS = 0x00 # Disables the ALERT output pin
ADC121C021_CONFIG_ALERT_PIN_EN = 0x04 # Enables the ALERT output pin
ADC121C021_CONFIG_POLARITY_LOW = 0x00 # Sets the ALERT pin to active low
ADC121C021_CONFIG_POLARITY_HIGH = 0x01 # Sets the ALERT pin to active high
class ADC121C021():
def __init__(self):
self.data_config()
def data_config(self):
"""Select the Configuration Register data from the given provided values"""
DATA_CONFIG = (ADC121C021_CONFIG_CYCLE_TIME_32 | ADC121C021_CONFIG_ALERT_HOLD_CLEAR | ADC121C021_CONFIG_ALERT_FLAG_DIS)
bus.write_byte_data(ADC121C021_DEFAULT_ADDRESS, ADC121C021_REG_CONFIG, DATA_CONFIG)
def read_adc(self):
"""Read data back from ADC121C021_REG_CONVERSION(0x00), 2 bytes
raw_adc MSB, raw_adc LSB"""
data = bus.read_i2c_block_data(ADC121C021_DEFAULT_ADDRESS, ADC121C021_REG_CONVERSION, 2)
# Convert the data to 12-bits
raw_adc = (data[0] & 0x0F) * 256 + data[1]
return {'r' : raw_adc}
from ADC121C021 import ADC121C021
adc121c021 = ADC121C021()
while True :
adc = adc121c021.read_adc()
print "Digital Value of Analog Input : %d "%(adc['r'])
print " ********************************* "
time.sleep(1)