Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathAS1115.py
More file actions
executable file
·106 lines (92 loc) · 5.04 KB
/
Copy pathAS1115.py
File metadata and controls
executable file
·106 lines (92 loc) · 5.04 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
# Distributed with a free-will license.
# Use it any way you want, profit or free, provided it fits in the licenses of its associated works.
# AS1115
# This code is designed to work with the AS1115_I2CL_3CE I2C Mini Module available from ControlEverything.com.
# https://www.controleverything.com/content/LED-Display?sku=AS1115_I2CL_3CE#tabs-0-product_tabset-2
# NT
import smbus
import time
# Get I2C bus
bus = smbus.SMBus(1)
# I2C address of the device
AS1115_DEFAULT_ADDRESS = 0x00
# AS1115 Digit & Control Register Map
AS1115_REG_DIGIT0 = 0x01 # Digit 0 Register
AS1115_REG_DIGIT1 = 0x02 # Digit 1 Register
AS1115_REG_DIGIT2 = 0x03 # Digit 2 Register
AS1115_REG_DIGIT3 = 0x04 # Digit 3 Register
AS1115_REG_DIGIT4 = 0x05 # Digit 4 Register
AS1115_REG_DIGIT5 = 0x06 # Digit 5 Register
AS1115_REG_DIGIT6 = 0x07 # Digit 6 Register
AS1115_REG_DIGIT7 = 0x08 # Digit 7 Register
AS1115_REG_DECODE_MODE = 0x09 # Decode Enable Register
AS1115_REG_GLOBAL_INTEN = 0x0A # Intensity Control Register
AS1115_REG_SCAN_LIMIT = 0x0B # Scan-Limit Register
AS1115_REG_SHUTDOWN = 0x0C # Shutdown Register
AS1115_REG_FEATURE = 0x0E # Feature Register
AS1115_REG_DISP_TEST = 0x0F # Display-Test Mode
AS1115_REG_DIGIT01_INTEN = 0x10 # Digit 0-1 Intensity Control Register
AS1115_REG_DIGIT23_INTEN = 0x11 # Digit 2-3 Intensity Control Register
AS1115_REG_DIGIT45_INTEN = 0x12 # Digit 4-5 Intensity Control Register
AS1115_REG_DIGIT67_INTEN = 0x13 # Digit 6-7 Intensity Control Register
# AS1115 Shutdown Register Configuration
AS1115_SHUTDOWN_FEATURE_RESET = 0x00 # Shutdown Mode, Reset Feature Register to Default Settings
AS1115_SHUTDOWN_FEATURE_UNCHANGED = 0x80 # Shutdown Mode, Feature Register Unchanged
AS1115_NORMAL_FEATURE_RESET = 0x01 # Normal Operation, Reset Feature Register to Default Settings
AS1115_NORMAL_FEATURE_UNCHANGED = 0x81 # Normal Operation, Feature Register Unchanged
# AS1115 Feature Register Configuration
AS1115_FEATURE_CLK_IN = 0x00 # Internal oscillator is used for system clock
AS1115_FEATURE_CLK_EN = 0x01 # Pin CLK of the serial interface operates as system clock input
AS1115_FEATURE_RESET_DS = 0x00 # Reset Disabled. Normal operation
AS1115_FEATURE_RESET_EN = 0x02 # All control registers are reset to default state
AS1115_FEATURE_DECODE_CODEB = 0x00 # Enable Code-B decoding
AS1115_FEATURE_DECODE_HEX = 0x04 # Enable HEX decoding
AS1115_FEATURE_BLINK_DS = 0x00 # Disable blinking
AS1115_FEATURE_BLINK_EN = 0x10 # Enable blinking
AS1115_FEATURE_BLINKFREQ_1 = 0x00 # Blink period typically is 1 second
AS1115_FEATURE_BLINKFREQ_2 = 0x20 # Blink period is 2 second
AS1115_FEATURE_BLINKSYNC = 0x40 # The blink timing can be synchronized across all the devices
AS1115_FEATURE_BLINKOFF = 0x00 # Blinking starts with the display turned off
AS1115_FEATURE_BLINKSTART = 0x80 # Blinking starts with the display turned on
# AS1115 Decode Register Configuration
AS1115_DECODE_NODIGIT = 0x00 # No decode for digits 7:0
AS1115_DECODE_DIGIT_0 = 0x01 # Code-B/HEX decode for digit 0, No decode for digits 7:1
AS1115_DECODE_DIGIT_0_2 = 0x07 # Code-B/HEX decode for digit 0-2, No decode for digits 7:3
AS1115_DECODE_DIGIT_0_5 = 0x3F # Code-B/HEX decode for digit 0-5, No decode for digits 7:6
AS1115_DECODE_DIGIT_0_2_5 = 0x25 # Code-B/HEX decode for digit 0,2,5, No decode for digits 1,3,4,6,7
# AS1115 Scan-Limit Register Configuration
AS1115_SCAN_DIGIT_0 = 0x00 # Display digit 0 only
AS1115_SCAN_DIGIT_01 = 0x01 # Display digit 0-1
AS1115_SCAN_DIGIT_02 = 0x02 # Display digit 0-2
AS1115_SCAN_DIGIT_03 = 0x03 # Display digit 0-3
AS1115_SCAN_DIGIT_04 = 0x04 # Display digit 0-4
AS1115_SCAN_DIGIT_05 = 0x05 # Display digit 0-5
AS1115_SCAN_DIGIT_06 = 0x06 # Display digit 0-6
AS1115_SCAN_DIGIT_07 = 0x07 # Display digit 0-7
class AS1115():
def mode_config(self):
"""Select the Shutdown register configuration from the given provided values"""
bus.write_byte_data(AS1115_DEFAULT_ADDRESS, AS1115_REG_SHUTDOWN, AS1115_NORMAL_FEATURE_RESET)
def feature_config(self):
"""Select the Feature register configuration from the given provided values"""
bus.write_byte_data(AS1115_DEFAULT_ADDRESS, AS1115_REG_FEATURE, AS1115_FEATURE_DECODE_HEX)
def display_config(self):
"""Select the Scan-Limit register configuration from the given provided values"""
bus.write_byte_data(AS1115_DEFAULT_ADDRESS, AS1115_REG_SCAN_LIMIT, AS1115_SCAN_DIGIT_02)
def decode_config(self):
"""Select the Decode register configuration from the given provided values"""
bus.write_byte_data(AS1115_DEFAULT_ADDRESS, AS1115_REG_DECODE_MODE, AS1115_DECODE_DIGIT_0_2)
from AS1115 import AS1115
as1115 = AS1115()
as1115.mode_config()
as1115.feature_config()
as1115.display_config()
as1115.decode_config()
time.sleep(0.2)
for data in range(0, 16):
for digit in range(3):
# Write data on the digits
bus.write_byte_data(0x00, digit+1, data)
# Output to screen
print "Display on 7-Segment : ",hex(data)
time.sleep(0.8)