Skip to content

MT12 -shuts down on first power up attempt #6874

@pitts-mo

Description

@pitts-mo

Is there an existing issue for this problem?

  • I have searched the existing issues

What part of EdgeTX is the focus of this bug?

Transmitter firmware

Current Behavior

The RadioMaster MT12 radio (currently v2.11.3) will shut down on first power up attempt when internal ELRS is enabled for the current model and TX battery is less than ~6.9 volts.

-Powering up a second time usually results in a working EdgeTX session.
-Selecting a model without internal ELRS before shutdown or setting switch positions to trigger warnings on boot will prevent the MT12 from powering off and result in a working EdgeTX session.

Expected Behavior

MT12 EdgeTX to power UP on first attempt if TX battery voltage in normal operating range of 6.6-8.4V.

Steps To Reproduce

  1. Set current model to use internal ELRS (even just 10mw and backpack off)
  2. Manage TX battery to voltage to value between 6.6 and 6.9 volts
  3. turn off radio and let it stay off for a few minutes
  4. attempt to turn on radio (MT12 shuts off immediately after boot sequence)
  5. attempt to turn on radio (usually MT12 will boot on second attempt -capacitor charged?)

Version

2.11.3

Transmitter

RadioMaster MT12

Operating System (OS)

Linux

OS Version

No response

Anything else?

I suspect the root cause is a quirk of hardware design. However, I am not the only one to observe this and I suspect timing of powering on the internal module could provide a fix for this.