Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathbackup_helpers.py
More file actions
669 lines (567 loc) · 22.6 KB
/
backup_helpers.py
File metadata and controls
669 lines (567 loc) · 22.6 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
"""
Hilfslogik für Backup-/Stromausfall-Bewertungen der EcoFlow PowerOcean Integration.
Zweck:
Dieses Modul kapselt alle abgeleiteten Berechnungen rund um Backup Helpers:
- Normalisierte Leistungswerte
- Nutzbare Energie oberhalb einer Reserve
- Geglättete Last für Restlaufzeit-Schätzungen
- Robuste Stromausfall-Heuristik
Input:
- Coordinator-Daten (`dict[str, Any]`) aus MQTT / Protobuf-Dekodierung
- Options-Flow-Werte für Backup Helpers
- Kleine In-Memory-Historie der letzten Snapshots
Output:
- Normalisierte Optionswerte
- Einzelne Snapshots für Backup-Bewertungen
- Zusammengefasste `BackupEvaluation`
Wichtige Invarianten:
- Keine Netzwerkzugriffe und keine Home-Assistant-I/O in diesem Modul
- Bei unsicheren oder unplausiblen Daten lieber `None` als Fantasiewerte
- Stromausfall-Erkennung soll konservativ sein und Fehlalarme minimieren
Debug-Hinweis:
- Dieses Modul liefert erklärende Statusfelder wie `outage_reason`,
`smoothed_load_power_w` und `runtime_estimate_minutes`.
- Diese Werte können über Entity-Attribute oder Diagnostics geprüft werden.
"""
from __future__ import annotations
from dataclasses import asdict, dataclass
from datetime import UTC, datetime, timedelta
from typing import Any, Mapping, Sequence
from .const import (
BACKUP_CRITICAL_RUNTIME_MINUTES_MAX,
BACKUP_CRITICAL_RUNTIME_MINUTES_MIN,
BACKUP_RESERVED_SOC_PERCENT_MAX,
BACKUP_RESERVED_SOC_PERCENT_MIN,
CONF_BACKUP_CRITICAL_RUNTIME_MINUTES,
CONF_BACKUP_RESERVED_SOC_PERCENT,
CONF_BACKUP_RUNTIME_SMOOTHING_MINUTES,
CONF_ENABLE_BACKUP_HELPERS,
CONF_POWER_OUTAGE_FREQUENCY_MIN_HZ,
CONF_POWER_OUTAGE_GRID_POWER_THRESHOLD_W,
DATA_BATTERIES,
DATA_EMS_HEARTBEAT,
DATA_ENERGY_STREAM,
DEFAULT_BACKUP_CRITICAL_RUNTIME_MINUTES,
DEFAULT_BACKUP_RESERVED_SOC_PERCENT,
DEFAULT_BACKUP_RUNTIME_SMOOTHING_MINUTES,
DEFAULT_ENABLE_BACKUP_HELPERS,
DEFAULT_POWER_OUTAGE_FREQUENCY_MIN_HZ,
DEFAULT_POWER_OUTAGE_GRID_POWER_THRESHOLD_W,
POWER_OUTAGE_FREQUENCY_MIN_HZ_MAX,
POWER_OUTAGE_FREQUENCY_MIN_HZ_MIN,
POWER_OUTAGE_GRID_POWER_THRESHOLD_W_MAX,
POWER_OUTAGE_GRID_POWER_THRESHOLD_W_MIN,
BACKUP_RUNTIME_SMOOTHING_MINUTES_MAX,
BACKUP_RUNTIME_SMOOTHING_MINUTES_MIN,
)
# Kleine Netzleistungen liegen häufig nur im Messrauschen.
GRID_SIGN_DEADBAND_W = 20.0
# Ein Vorzeichenwechsel wird nur akzeptiert, wenn die Bilanz spürbar besser wird.
MIN_SIGN_FLIP_IMPROVEMENT_W = 20.0
# Outage-Erkennung bewusst konservativ:
# - Hauslast muss spürbar vorhanden sein
# - Lokale Versorgung muss sichtbar sein
# - mehrere Samples über ein kurzes Zeitfenster müssen dieselben Bedingungen zeigen
MIN_BACKUP_LOAD_W = 100.0
MIN_LOCAL_SUPPLY_W = 100.0
OUTAGE_CONFIRMATION_SECONDS = 45
MIN_OUTAGE_SAMPLES = 2
BACKUP_HISTORY_MINUTES = 20
BACKUP_ACTION_NORMAL = "normal"
BACKUP_ACTION_SHED_LOAD = "shed_load"
BACKUP_ACTION_SHUTDOWN_RECOMMENDED = "shutdown_recommended"
BACKUP_ACTION_UNKNOWN = "unknown"
BACKUP_RECOMMENDED_ACTION_OPTIONS = [
BACKUP_ACTION_NORMAL,
BACKUP_ACTION_SHED_LOAD,
BACKUP_ACTION_SHUTDOWN_RECOMMENDED,
BACKUP_ACTION_UNKNOWN,
]
@dataclass(frozen=True, slots=True)
class BackupHelperConfig:
"""Normalisierte Backup-Helper-Konfiguration."""
enabled: bool
reserved_soc_percent: int
grid_power_threshold_w: int
frequency_min_hz: float
runtime_smoothing_minutes: int
critical_runtime_minutes: int
@dataclass(frozen=True, slots=True)
class BackupSnapshot:
"""
Einzelner Messpunkt für Backup-Bewertungen.
Beispiel:
Input:
soc=55, energy_wh=10800, load=780, solar=0, battery=750, grid=5, freq=None
Output:
Snapshot mit denselben normalisierten Kernwerten und UTC-Zeitstempel
"""
observed_at: datetime
total_soc_percent: int | None
total_energy_wh: float | None
load_power_w: float | None
grid_power_w: float | None
solar_power_w: float | None
battery_power_w: float | None
grid_frequency_hz: float | None
@dataclass(frozen=True, slots=True)
class BackupEvaluation:
"""Abgeleitete Backup-Bewertung aus letzter Datenlage und kurzer Historie."""
enabled: bool
observed_at: datetime | None
usable_energy_wh: float | None
smoothed_load_power_w: float | None
runtime_estimate_minutes: float | None
runtime_estimate_hours: float | None
backup_reserve_critical: bool
power_outage: bool
backup_active: bool
recommended_action: str
outage_reason: str
has_seen_valid_grid_frequency: bool
def as_dict(self) -> dict[str, Any]:
"""Hilfsdarstellung für Diagnostics und Debug-Attribute."""
return asdict(self)
def _clamp(value: float, minimum: float, maximum: float) -> float:
"""Begrenzt einen numerischen Wert sicher auf einen gültigen Bereich."""
return max(minimum, min(maximum, value))
def _coerce_int(value: Any, default: int, minimum: int, maximum: int) -> int:
"""Konvertiert Eingaben robust zu int und wendet Grenzen an."""
try:
coerced = int(float(value))
except (TypeError, ValueError):
coerced = default
return int(_clamp(coerced, minimum, maximum))
def _coerce_float(value: Any, default: float, minimum: float, maximum: float) -> float:
"""Konvertiert Eingaben robust zu float und wendet Grenzen an."""
try:
coerced = float(value)
except (TypeError, ValueError):
coerced = default
return float(_clamp(coerced, minimum, maximum))
def normalize_backup_helper_options(raw_options: Mapping[str, Any]) -> dict[str, Any]:
"""
Normalisiert alle Backup-Helper-Optionen in einer zentralen Stelle.
Warum:
Sowohl Options Flow als auch Coordinator sollen mit denselben Regeln
arbeiten. So vermeiden wir doppelte Validierungslogik.
"""
return {
CONF_ENABLE_BACKUP_HELPERS: bool(
raw_options.get(CONF_ENABLE_BACKUP_HELPERS, DEFAULT_ENABLE_BACKUP_HELPERS)
),
CONF_BACKUP_RESERVED_SOC_PERCENT: _coerce_int(
raw_options.get(
CONF_BACKUP_RESERVED_SOC_PERCENT,
DEFAULT_BACKUP_RESERVED_SOC_PERCENT,
),
DEFAULT_BACKUP_RESERVED_SOC_PERCENT,
BACKUP_RESERVED_SOC_PERCENT_MIN,
BACKUP_RESERVED_SOC_PERCENT_MAX,
),
CONF_POWER_OUTAGE_GRID_POWER_THRESHOLD_W: _coerce_int(
raw_options.get(
CONF_POWER_OUTAGE_GRID_POWER_THRESHOLD_W,
DEFAULT_POWER_OUTAGE_GRID_POWER_THRESHOLD_W,
),
DEFAULT_POWER_OUTAGE_GRID_POWER_THRESHOLD_W,
POWER_OUTAGE_GRID_POWER_THRESHOLD_W_MIN,
POWER_OUTAGE_GRID_POWER_THRESHOLD_W_MAX,
),
CONF_POWER_OUTAGE_FREQUENCY_MIN_HZ: _coerce_float(
raw_options.get(
CONF_POWER_OUTAGE_FREQUENCY_MIN_HZ,
DEFAULT_POWER_OUTAGE_FREQUENCY_MIN_HZ,
),
DEFAULT_POWER_OUTAGE_FREQUENCY_MIN_HZ,
POWER_OUTAGE_FREQUENCY_MIN_HZ_MIN,
POWER_OUTAGE_FREQUENCY_MIN_HZ_MAX,
),
CONF_BACKUP_RUNTIME_SMOOTHING_MINUTES: _coerce_int(
raw_options.get(
CONF_BACKUP_RUNTIME_SMOOTHING_MINUTES,
DEFAULT_BACKUP_RUNTIME_SMOOTHING_MINUTES,
),
DEFAULT_BACKUP_RUNTIME_SMOOTHING_MINUTES,
BACKUP_RUNTIME_SMOOTHING_MINUTES_MIN,
BACKUP_RUNTIME_SMOOTHING_MINUTES_MAX,
),
CONF_BACKUP_CRITICAL_RUNTIME_MINUTES: _coerce_int(
raw_options.get(
CONF_BACKUP_CRITICAL_RUNTIME_MINUTES,
DEFAULT_BACKUP_CRITICAL_RUNTIME_MINUTES,
),
DEFAULT_BACKUP_CRITICAL_RUNTIME_MINUTES,
BACKUP_CRITICAL_RUNTIME_MINUTES_MIN,
BACKUP_CRITICAL_RUNTIME_MINUTES_MAX,
),
}
def backup_helper_config_from_mapping(raw_options: Mapping[str, Any]) -> BackupHelperConfig:
"""Erzeugt aus beliebigen Optionen eine typsichere Backup-Konfiguration."""
normalized = normalize_backup_helper_options(raw_options)
return BackupHelperConfig(
enabled=bool(normalized[CONF_ENABLE_BACKUP_HELPERS]),
reserved_soc_percent=int(normalized[CONF_BACKUP_RESERVED_SOC_PERCENT]),
grid_power_threshold_w=int(
normalized[CONF_POWER_OUTAGE_GRID_POWER_THRESHOLD_W]
),
frequency_min_hz=float(normalized[CONF_POWER_OUTAGE_FREQUENCY_MIN_HZ]),
runtime_smoothing_minutes=int(
normalized[CONF_BACKUP_RUNTIME_SMOOTHING_MINUTES]
),
critical_runtime_minutes=int(
normalized[CONF_BACKUP_CRITICAL_RUNTIME_MINUTES]
),
)
def backup_history_retention_minutes(config: BackupHelperConfig) -> int:
"""Länge der In-Memory-Historie für Glättung und Outage-Stabilität."""
return max(BACKUP_HISTORY_MINUTES, config.runtime_smoothing_minutes + 5)
def _ems_grid_power_w(data: Mapping[str, Any]) -> float:
"""Fallback: Netzleistung aus den drei Phasen (EMS_HEARTBEAT)."""
ems = data.get(DATA_EMS_HEARTBEAT)
if ems is None:
return 0.0
return float(ems.phase_a.act_pwr + ems.phase_b.act_pwr + ems.phase_c.act_pwr)
def _ems_solar_power_w(data: Mapping[str, Any]) -> float:
"""Fallback: Solarleistung als Summe aller MPPT-Strings."""
ems = data.get(DATA_EMS_HEARTBEAT)
if ems is None:
return 0.0
return float(sum(string.power_w for string in ems.mppt_strings))
def _ems_battery_power_w(data: Mapping[str, Any]) -> float:
"""Fallback: Batterieleistung aus EMS_HEARTBEAT."""
ems = data.get(DATA_EMS_HEARTBEAT)
if ems is None:
return 0.0
return float(ems.battery_power_w)
def normalized_power_components(data: Mapping[str, Any]) -> tuple[float, float, float, float]:
"""
Liefert normalisierte Leistungswerte als `(solar, grid, load, battery)`.
Warum:
Einige Firmwarestände liefern wechselnde Vorzeichenkonventionen.
Die physikalische Bilanz `load ~= solar + battery + grid` hilft,
die Rohwerte robust in ein konsistentes Modell zu überführen.
"""
stream = data.get(DATA_ENERGY_STREAM)
if stream is None:
solar = _ems_solar_power_w(data)
grid = _ems_grid_power_w(data)
battery = _ems_battery_power_w(data)
load = solar + battery + grid
return solar, grid, load, battery
solar = float(stream.solar_w)
load = float(stream.load_w)
grid_raw = float(stream.grid_w)
battery_raw = float(stream.battery_w)
if abs(grid_raw) <= GRID_SIGN_DEADBAND_W:
grid = grid_raw
else:
err_grid_keep = abs((solar + battery_raw + grid_raw) - load)
err_grid_flip = abs((solar + battery_raw - grid_raw) - load)
grid = -grid_raw if (err_grid_keep - err_grid_flip) >= MIN_SIGN_FLIP_IMPROVEMENT_W and err_grid_flip < err_grid_keep else grid_raw
battery_expected = load - solar - grid
err_batt_keep = abs(battery_raw - battery_expected)
err_batt_flip = abs((-battery_raw) - battery_expected)
battery = -battery_raw if (err_batt_keep - err_batt_flip) >= MIN_SIGN_FLIP_IMPROVEMENT_W and err_batt_flip < err_batt_keep else battery_raw
return solar, grid, load, battery
def solar_power_w(data: Mapping[str, Any]) -> float:
"""Solarleistung in Watt."""
return normalized_power_components(data)[0]
def grid_power_w(data: Mapping[str, Any]) -> float:
"""Netzleistung in Watt, positiv für Bezug und negativ für Einspeisung."""
return normalized_power_components(data)[1]
def load_power_w(data: Mapping[str, Any]) -> float:
"""Hausverbrauch in Watt."""
return normalized_power_components(data)[2]
def battery_power_w(data: Mapping[str, Any]) -> float:
"""Batterieleistung in Watt, positiv für Entladen und negativ für Laden."""
return normalized_power_components(data)[3]
def total_soc_percent(data: Mapping[str, Any]) -> int | None:
"""Gesamt-SOC bevorzugt aus ENERGY_STREAM, sonst Mittelwert aller Packs."""
stream = data.get(DATA_ENERGY_STREAM)
if stream is not None:
try:
stream_soc = int(getattr(stream, "soc", 0))
except (TypeError, ValueError):
stream_soc = 0
if 0 <= stream_soc <= 100:
return stream_soc
batteries = data.get(DATA_BATTERIES, {})
if not batteries:
return None
return int(sum(pack.soc for pack in batteries.values()) / len(batteries))
def total_energy_wh(data: Mapping[str, Any]) -> float | None:
"""
Liefert die aktuell verfügbare Batterie-Gesamtenergie in Wh.
Bevorzugt wird der Systemwert aus `EMS_HEARTBEAT.bp_remain_wh`.
Falls dieser fehlt, wird die Summe der Einzelpacks verwendet.
"""
ems = data.get(DATA_EMS_HEARTBEAT)
if ems is not None:
try:
bp_remain_wh = float(getattr(ems, "bp_remain_wh", 0.0))
except (TypeError, ValueError):
bp_remain_wh = 0.0
if bp_remain_wh > 0:
return bp_remain_wh
batteries = data.get(DATA_BATTERIES, {})
if not batteries:
return None
remaining_values = [
float(pack.remaining_wh)
for pack in batteries.values()
if getattr(pack, "remaining_wh", 0) > 0
]
if not remaining_values:
return None
return sum(remaining_values)
def grid_frequency_hz(data: Mapping[str, Any]) -> float | None:
"""Netzfrequenz in Hz oder `None`, wenn kein brauchbarer Wert vorhanden ist."""
ems = data.get(DATA_EMS_HEARTBEAT)
if ems is None:
return None
try:
frequency = float(getattr(ems, "frequency_hz", 0.0))
except (TypeError, ValueError):
return None
return frequency if frequency >= 0.1 else None
def build_backup_snapshot(
data: Mapping[str, Any],
observed_at: datetime | None = None,
) -> BackupSnapshot:
"""Erzeugt einen normalisierten Snapshot aus den aktuellen Coordinator-Daten."""
timestamp = observed_at or datetime.now(UTC)
return BackupSnapshot(
observed_at=timestamp,
total_soc_percent=total_soc_percent(data),
total_energy_wh=total_energy_wh(data),
load_power_w=load_power_w(data),
grid_power_w=grid_power_w(data),
solar_power_w=solar_power_w(data),
battery_power_w=battery_power_w(data),
grid_frequency_hz=grid_frequency_hz(data),
)
def trim_backup_history(
snapshots: Sequence[BackupSnapshot],
*,
now: datetime,
retention_minutes: int,
) -> list[BackupSnapshot]:
"""Schneidet eine Snapshot-Historie zeitbasiert zu."""
cutoff = now - timedelta(minutes=retention_minutes)
return [snapshot for snapshot in snapshots if snapshot.observed_at >= cutoff]
def calculate_backup_usable_energy_wh(
total_energy_wh_value: float | None,
soc_percent: int | None,
reserved_soc_percent: int,
) -> float | None:
"""
Berechnet die oberhalb der Reserve nutzbare Energie.
Formel laut Produktentscheidung:
usable_energy_wh = max(total_energy_wh * ((soc - reserve) / 100), 0)
"""
if total_energy_wh_value is None or soc_percent is None:
return None
if total_energy_wh_value <= 0:
return None
if not 0 <= soc_percent <= 100:
return None
usable_energy_wh = total_energy_wh_value * (
(soc_percent - reserved_soc_percent) / 100.0
)
return round(max(usable_energy_wh, 0.0), 1)
def smoothed_load_power_w(
snapshots: Sequence[BackupSnapshot],
*,
now: datetime,
smoothing_minutes: int,
) -> float | None:
"""Glättet den Hausverbrauch über ein Zeitfenster, um Peak-Rauschen zu entschärfen."""
window_start = now - timedelta(minutes=smoothing_minutes)
loads = [
float(snapshot.load_power_w)
for snapshot in snapshots
if snapshot.observed_at >= window_start
and snapshot.load_power_w is not None
and snapshot.load_power_w > 0
]
if not loads:
return None
return round(sum(loads) / len(loads), 1)
def runtime_estimate_minutes(
*,
usable_energy_wh_value: float | None,
smoothed_load_power_w_value: float | None,
latest_load_power_w_value: float | None,
) -> float | None:
"""Schätzt die Restlaufzeit in Minuten oder `None`, wenn keine sinnvolle Schätzung möglich ist."""
if usable_energy_wh_value is None or smoothed_load_power_w_value is None:
return None
if usable_energy_wh_value <= 0:
return 0.0
if latest_load_power_w_value is None or latest_load_power_w_value <= 0:
return None
if smoothed_load_power_w_value <= 0:
return None
return round((usable_energy_wh_value / smoothed_load_power_w_value) * 60.0, 1)
def _sample_indicates_local_supply(
snapshot: BackupSnapshot,
*,
min_local_supply_w: float,
) -> bool:
"""Prüft, ob PV/Batterie lokal genug Leistung bereitstellen, um Inselbetrieb zu stützen."""
solar = max(snapshot.solar_power_w or 0.0, 0.0)
battery_discharge = max(snapshot.battery_power_w or 0.0, 0.0)
return (solar + battery_discharge) >= min_local_supply_w
def _sample_indicates_house_load(
snapshot: BackupSnapshot,
*,
min_backup_load_w: float,
) -> bool:
"""Prüft, ob am Haus eine echte Last anliegt und nicht nur Leerlaufrauschen."""
return (snapshot.load_power_w or 0.0) >= min_backup_load_w
def _sample_indicates_grid_quiet(
snapshot: BackupSnapshot,
*,
grid_power_threshold_w: int,
) -> bool:
"""Prüft, ob die Netzleistung keine normale Versorgung erkennen lässt."""
return abs(snapshot.grid_power_w or 0.0) <= float(grid_power_threshold_w)
def _recent_outage_samples(
snapshots: Sequence[BackupSnapshot],
*,
now: datetime,
) -> list[BackupSnapshot]:
"""Liefert nur den kurzen, stabilen Zeitraum für die Outage-Heuristik."""
window_start = now - timedelta(seconds=OUTAGE_CONFIRMATION_SECONDS)
return [snapshot for snapshot in snapshots if snapshot.observed_at >= window_start]
def evaluate_backup_state(
snapshots: Sequence[BackupSnapshot],
*,
config: BackupHelperConfig,
has_seen_valid_grid_frequency: bool,
) -> BackupEvaluation:
"""
Leitet aus Snapshot-Historie eine konservative Backup-/Outage-Bewertung ab.
Stromausfall-Heuristik:
Ein Ausfall wird erst dann als "wahrscheinlich" gewertet, wenn über einen
kurzen stabilen Zeitraum gleichzeitig gilt:
- Frequenzsignal war grundsätzlich schon einmal brauchbar und ist jetzt
fehlend/unter Mindestfrequenz
- Netzleistung bleibt nahe null
- Hauslast ist vorhanden
- PV/Batterie versorgen das Haus plausibel lokal weiter
Diese Heuristik vermeidet absichtlich Fehlalarme im normalen Nullpunktbetrieb.
"""
latest = snapshots[-1] if snapshots else None
if not config.enabled or latest is None:
return BackupEvaluation(
enabled=False,
observed_at=latest.observed_at if latest is not None else None,
usable_energy_wh=None,
smoothed_load_power_w=None,
runtime_estimate_minutes=None,
runtime_estimate_hours=None,
backup_reserve_critical=False,
power_outage=False,
backup_active=False,
recommended_action=BACKUP_ACTION_UNKNOWN,
outage_reason="backup_helpers_disabled",
has_seen_valid_grid_frequency=has_seen_valid_grid_frequency,
)
now = latest.observed_at
smoothed_load = smoothed_load_power_w(
snapshots,
now=now,
smoothing_minutes=config.runtime_smoothing_minutes,
)
usable_energy = calculate_backup_usable_energy_wh(
latest.total_energy_wh,
latest.total_soc_percent,
config.reserved_soc_percent,
)
runtime_minutes_value = runtime_estimate_minutes(
usable_energy_wh_value=usable_energy,
smoothed_load_power_w_value=smoothed_load,
latest_load_power_w_value=latest.load_power_w,
)
runtime_hours_value = (
round(runtime_minutes_value / 60.0, 2)
if runtime_minutes_value is not None
else None
)
backup_reserve_critical = (
runtime_minutes_value is not None
and runtime_minutes_value <= config.critical_runtime_minutes
)
recent_samples = _recent_outage_samples(snapshots, now=now)
min_load = max(MIN_BACKUP_LOAD_W, float(config.grid_power_threshold_w) * 2.0)
min_local_supply = max(
MIN_LOCAL_SUPPLY_W,
float(config.grid_power_threshold_w) * 2.0,
)
if len(recent_samples) < MIN_OUTAGE_SAMPLES:
power_outage = False
outage_reason = "awaiting_stable_samples"
elif not has_seen_valid_grid_frequency:
power_outage = False
outage_reason = "grid_frequency_signal_unavailable"
elif not all(
(sample.grid_frequency_hz is None or sample.grid_frequency_hz < config.frequency_min_hz)
for sample in recent_samples
):
power_outage = False
outage_reason = "grid_frequency_still_present"
elif not all(
_sample_indicates_grid_quiet(
sample,
grid_power_threshold_w=config.grid_power_threshold_w,
)
for sample in recent_samples
):
power_outage = False
outage_reason = "grid_power_above_threshold"
elif not all(
_sample_indicates_house_load(sample, min_backup_load_w=min_load)
for sample in recent_samples
):
power_outage = False
outage_reason = "house_load_too_low"
elif not all(
_sample_indicates_local_supply(
sample,
min_local_supply_w=min_local_supply,
)
for sample in recent_samples
):
power_outage = False
outage_reason = "local_supply_not_detected"
else:
power_outage = True
outage_reason = "grid_outage_likely"
backup_active = power_outage and _sample_indicates_local_supply(
latest,
min_local_supply_w=min_local_supply,
)
if runtime_minutes_value is None:
recommended_action = BACKUP_ACTION_UNKNOWN
elif runtime_minutes_value <= max(15, config.critical_runtime_minutes / 2):
recommended_action = BACKUP_ACTION_SHUTDOWN_RECOMMENDED
elif runtime_minutes_value <= config.critical_runtime_minutes:
recommended_action = BACKUP_ACTION_SHED_LOAD
else:
recommended_action = BACKUP_ACTION_NORMAL
return BackupEvaluation(
enabled=True,
observed_at=latest.observed_at,
usable_energy_wh=usable_energy,
smoothed_load_power_w=smoothed_load,
runtime_estimate_minutes=runtime_minutes_value,
runtime_estimate_hours=runtime_hours_value,
backup_reserve_critical=backup_reserve_critical,
power_outage=power_outage,
backup_active=backup_active,
recommended_action=recommended_action,
outage_reason=outage_reason,
has_seen_valid_grid_frequency=has_seen_valid_grid_frequency,
)