Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy path(KWH_4).m
More file actions
156 lines (136 loc) · 5.3 KB
/
(KWH_4).m
File metadata and controls
156 lines (136 loc) · 5.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
%% MASTER SCRIPT: Energy & Temperature Profile (Exp 4)
% Style: CLEAN (No Title, No Legend) + Dynamic Limits + Table
% COLORS: Automated Viridis Import
clear; clc; close all;
% --- 1. CONFIGURATION & COLORS (Using installed 'viridis') ---
fileNTC = 'TEST_EMPTY_4.txt';
fileKWH = 'KWH_HEAT_UP_EMPTY_4.txt';
% Importiere 5 Abstufungen der Viridis-Palette
try
cols = viridis(5);
catch
error('Das Paket "viridis" wurde nicht gefunden. Bitte via Add-Ons installieren.');
end
c_Energy = [0, 0, 0];
c_TempIn = cols(4,:);
c_TempOut = cols(5,:);
c_RefLine = [0.50, 0.50, 0.50];
t_TargetReached_Min = 25.133;
% Manuelle Vergleichsdaten (Exp 1-3)
data_Exp1 = [0.055, 2368];
data_Exp2 = [0.029, 1499];
data_Exp3 = [0.009, 450];
%% 2. DATA PROCESSING (NTC)
if ~isfile(fileNTC), warning('File missing: %s', fileNTC); return; end
opts = detectImportOptions(fileNTC, 'NumHeaderLines', 0);
try
fid = fopen(fileNTC, 'r'); rawLines = textscan(fid, '%s', 'Delimiter', '\n'); fclose(fid);
hIdx = find(contains(rawLines{1}, 'Time_Sec'), 1, 'first');
opts.VariableNamesLine = hIdx; opts.DataLine = hIdx+1;
T_NTC = readtable(fileNTC, opts);
catch
warning('Fehler beim Lesen der NTC Datei.'); return;
end
if iscell(T_NTC.Time_Sec), T_NTC.Time_Sec = str2double(T_NTC.Time_Sec); end
if iscell(T_NTC.T_Innen), T_NTC.T_Innen = str2double(T_NTC.T_Innen); end
if iscell(T_NTC.T_Aussen), T_NTC.T_Aussen = str2double(T_NTC.T_Aussen); end
if iscell(T_NTC.Heizung), T_NTC.Heizung = str2double(T_NTC.Heizung); end
T_NTC = rmmissing(T_NTC);
rawTime = T_NTC.Time_Sec;
corrTime = rawTime; offset = 0;
for k=2:length(rawTime)
if rawTime(k) < rawTime(k-1), offset = offset + rawTime(k-1); end
corrTime(k) = rawTime(k) + offset;
end
T_NTC.Time_Abs = corrTime;
idxStart = find(T_NTC.Heizung > 0, 1, 'first');
if isempty(idxStart), t0 = 0; else, t0 = T_NTC.Time_Abs(idxStart); end
time_NTC_Min = (T_NTC.Time_Abs - t0) / 60.0;
%% 3. DATA PROCESSING (KWh)
if ~isfile(fileKWH), warning('File missing: %s', fileKWH); return; end
fid = fopen(fileKWH, 'r');
kwh_data = [];
while ~feof(fid)
line = fgetl(fid);
vals = sscanf(line, '%f,%f');
if length(vals) == 2, kwh_data = [kwh_data; vals']; end
end
fclose(fid);
if isempty(kwh_data)
time_KWh_Min = 0; val_KWh = 0; val_KWh_Smooth = 0;
else
time_KWh_Min = kwh_data(:,1) / 60.0;
val_KWh = kwh_data(:,2);
val_KWh_Smooth = smoothdata(val_KWh, 'gaussian', 10);
end
%% 4. CALCULATIONS
[~, idxCut] = min(abs(time_KWh_Min - t_TargetReached_Min));
if isempty(idxCut), energy_HeatUp = 0; else, energy_HeatUp = val_KWh(idxCut); end
% Holding Power Calc
t_Hold_Min = time_KWh_Min(idxCut:end);
e_Hold_kWh = val_KWh(idxCut:end);
if length(t_Hold_Min) > 5
t_Hold_Hours = (t_Hold_Min - t_Hold_Min(1)) / 60.0;
e_Hold_Delta = e_Hold_kWh - e_Hold_kWh(1);
p = polyfit(t_Hold_Hours, e_Hold_Delta, 1);
power_Hold_Exp4 = p(1);
else
power_Hold_Exp4 = NaN;
end
% Exp 1-3 Power
P1 = data_Exp1(1) / (data_Exp1(2)/3600);
P2 = data_Exp2(1) / (data_Exp2(2)/3600);
P3 = data_Exp3(1) / (data_Exp3(2)/3600);
all_Hold_Powers = [P1, P2, P3, power_Hold_Exp4];
%% 5. PLOTTING (CLEAN & DYNAMIC)
fig = figure('Color', 'w', 'Position', [100, 100, 900, 600]);
% --- AXIS SETUP ---
yyaxis left
ax = gca;
% -- Left Axis: Temperature (Viridis Index 2) --
set(ax, 'YColor', c_TempIn, 'FontName', 'Arial', 'FontSize', 16, 'LineWidth', 1.2, 'TickDir', 'out');
hold on;
mask = time_NTC_Min > -1.5;
% Plot Temp Innen
plot(time_NTC_Min(mask), T_NTC.T_Innen(mask), '-', 'Color', c_TempIn, 'LineWidth', 2.5);
% Plot Temp Aussen (Viridis Index 4 - Hellgrün)
plot(time_NTC_Min(mask), T_NTC.T_Aussen(mask), '-', 'Color', c_TempOut, 'LineWidth', 2.0);
ylabel('Temperature (°C)', 'FontWeight', 'bold');
% DYNAMIC LIMITS TEMP
maxTemp = max([max(T_NTC.T_Innen(mask)), max(T_NTC.T_Aussen(mask))]);
if isempty(maxTemp), maxTemp=80; end
ylim([20, maxTemp + 5]);
% -- Right Axis: Energy (Viridis Index 1 - Dark Purple) --
yyaxis right
set(ax, 'YColor', c_Energy);
ylabel('Energy Consumed (kWh)', 'FontWeight', 'bold');
plot(time_KWh_Min, val_KWh_Smooth, '-', 'Color', c_Energy, 'LineWidth', 3);
% DYNAMIC LIMITS ENERGY
maxE = max(val_KWh);
if maxE > 0
ylim([0, maxE * 1.05]);
else
ylim([0, 1]);
end
% -- Reference Line --
xline(t_TargetReached_Min, '--', 'Color', c_RefLine, 'LineWidth', 1.2);
% -- Styling (No Title, No Legend) --
grid on; box off;
xlabel('Time (min)', 'FontWeight', 'bold');
if max(time_KWh_Min) > 0
xlim([-1.5, max(time_KWh_Min) + 1]);
end
% Save
exportgraphics(fig, 'Exp4_Energy_Profile_Viridis.pdf', 'ContentType', 'vector');
%% 6. OUTPUT TABLE
fprintf('\n========================================\n');
fprintf(' HEAT LOSS ANALYSIS (HOLDING PHASE)\n');
fprintf(' Power required to maintain ~50°C\n');
fprintf('========================================\n');
fprintf(' Exp 1 (No Insulation): %6.3f kW\n', P1);
fprintf(' Exp 2 (Partial Iso): %6.3f kW\n', P2);
fprintf(' Exp 3 (Better Iso): %6.3f kW\n', P3);
fprintf(' Exp 4 (Full Auto): %6.3f kW\n', power_Hold_Exp4);
fprintf('----------------------------------------\n');
fprintf(' MEAN POWER LOSS: %6.3f kW\n', mean(all_Hold_Powers, 'omitnan'));
fprintf('========================================\n');