-
Notifications
You must be signed in to change notification settings - Fork 60
Expand file tree
/
Copy pathopenPDC.sql
More file actions
executable file
·2883 lines (2357 loc) · 113 KB
/
openPDC.sql
File metadata and controls
executable file
·2883 lines (2357 loc) · 113 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
-- ----------------------------------------------------------------------------------------------------
-- openPDC Data Structures for Oracle - Gbtc
--
-- Copyright © 2011, Grid Protection Alliance. All Rights Reserved.
--
-- Licensed to the Grid Protection Alliance (GPA) under one or more contributor license agreements. See
-- the NOTICE file distributed with this work for additional information regarding copyright ownership.
-- The GPA licenses this file to you under the MIT License (MIT), the "License"; you may
-- not use this file except in compliance with the License. You may obtain a copy of the License at:
--
-- http://www.opensource.org/licenses/MIT
--
-- Unless agreed to in writing, the subject software distributed under the License is distributed on an
-- "AS-IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. Refer to the
-- License for the specific language governing permissions and limitations.
--
-- Schema Modification History:
-- ----------------------------------------------------------------------------------------------------
-- 05/07/2011 - J. Ritchie Carroll
-- Generated original version of schema.
-- 03/27/2012 - prasanthgs
-- Added ExceptionLog table for keeping recent exceptions.
-- 04/12/2012 - prasanthgs
-- Reworked as per the comments of codeplex reviewers.
-- Added new field Type to ErrorLog table. Removed ExceptionLog table.
-- ----------------------------------------------------------------------------------------------------
-- The following statements are used to create a tablespace, user, and schema.
-- Be sure to change the password.
-- CREATE TABLESPACE openPDC_TS DATAFILE 'openPDC.dbf' SIZE 20M AUTOEXTEND ON;
-- CREATE TABLESPACE openPDC_INDEX DATAFILE 'openPDC_index.dbf' SIZE 20M AUTOEXTEND ON;
-- CREATE USER openPDC IDENTIFIED BY MyPassword DEFAULT TABLESPACE openPDC_TS;
-- GRANT UNLIMITED TABLESPACE TO openPDC;
-- GRANT CREATE SESSION TO openPDC;
-- ALTER SESSION SET CURRENT_SCHEMA = openPDC;
-- *******************************************************************************************
-- IMPORTANT NOTE: When making updates to this schema, please increment the version number!
-- *******************************************************************************************
CREATE VIEW SchemaVersion AS
SELECT 17 AS VersionNumber
FROM dual;
CREATE TABLE ErrorLog(
ID NUMBER NOT NULL,
Source VARCHAR2(200) NOT NULL,
Type VARCHAR2(4000) NULL,
Message VARCHAR2(4000) NOT NULL,
Detail VARCHAR2(4000) NULL,
CreatedOn DATE NOT NULL
);
CREATE UNIQUE INDEX IX_ErrorLog_ID ON ErrorLog (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE ErrorLog ADD CONSTRAINT PK_ErrorLog PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_ErrorLog START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_ErrorLog BEFORE INSERT ON ErrorLog
FOR EACH ROW BEGIN SELECT SEQ_ErrorLog.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Runtime(
ID NUMBER NOT NULL,
SourceID NUMBER NOT NULL,
SourceTable VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Runtime_Source ON Runtime (SourceID ASC, SourceTable ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Runtime_ID ON Runtime (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Runtime ADD CONSTRAINT PK_Runtime PRIMARY KEY (SourceID, SourceTable);
CREATE SEQUENCE SEQ_Runtime START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Runtime BEFORE INSERT ON Runtime
FOR EACH ROW BEGIN SELECT SEQ_Runtime.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE AuditLog(
ID NUMBER NOT NULL,
TableName VARCHAR2(200) NOT NULL,
PrimaryKeyColumn VARCHAR2(200) NOT NULL,
PrimaryKeyValue VARCHAR2(4000) NOT NULL,
ColumnName VARCHAR2(200) NOT NULL,
OriginalValue VARCHAR2(4000) NULL,
NewValue VARCHAR2(4000) NULL,
Deleted NUMBER DEFAULT 0 NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL
);
CREATE UNIQUE INDEX IX_AuditLog_ID ON AuditLog (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE AuditLog ADD CONSTRAINT PK_AuditLog PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_AuditLog START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_AuditLog BEFORE INSERT ON AuditLog
FOR EACH ROW BEGIN SELECT SEQ_AuditLog.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Company(
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
MapAcronym VARCHAR2(10) NOT NULL,
Name VARCHAR2(200) NOT NULL,
URL VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Company_ID ON Company (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Company ADD CONSTRAINT PK_Company PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Company START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Company BEFORE INSERT ON Company
FOR EACH ROW BEGIN SELECT SEQ_Company.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE TrackedChange(
ID NUMBER(19, 0) NOT NULL,
TableName VARCHAR2(200) NOT NULL,
PrimaryKeyColumn VARCHAR2(200) NOT NULL,
PrimaryKeyValue VARCHAR2(4000) NULL
);
CREATE UNIQUE INDEX IX_TrackedChange_ID ON TrackedChange (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE TrackedChange ADD CONSTRAINT PK_TrackedChange PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_TrackedChange START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_TrackedChange BEFORE INSERT ON TrackedChange
FOR EACH ROW BEGIN SELECT SEQ_TrackedChange.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE ConfigurationEntity(
SourceName VARCHAR2(200) NOT NULL,
RuntimeName VARCHAR2(200) NOT NULL,
Description VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL
);
CREATE TABLE Vendor(
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NULL,
Name VARCHAR2(200) NOT NULL,
PhoneNumber VARCHAR2(200) NULL,
ContactEmail VARCHAR2(200) NULL,
URL VARCHAR2(4000) NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Vendor_ID ON Vendor (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Vendor ADD CONSTRAINT PK_Vendor PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Vendor START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Vendor BEFORE INSERT ON Vendor
FOR EACH ROW BEGIN SELECT SEQ_Vendor.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Protocol(
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
Name VARCHAR2(200) NOT NULL,
Type VARCHAR2(200) DEFAULT 'Frame' NOT NULL,
Category VARCHAR2(200) DEFAULT 'Phasor' NOT NULL,
AssemblyName VARCHAR2(1024) DEFAULT 'PhasorProtocolAdapters.dll' NOT NULL,
TypeName VARCHAR2(200) DEFAULT 'PhasorProtocolAdapters.PhasorMeasurementMapper' NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL
);
CREATE UNIQUE INDEX IX_Protocol_ID ON Protocol (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Protocol ADD CONSTRAINT PK_Protocol PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Protocol START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Protocol BEFORE INSERT ON Protocol
FOR EACH ROW BEGIN SELECT SEQ_Protocol.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE SignalType(
ID NUMBER NOT NULL,
Name VARCHAR2(200) NOT NULL,
Acronym VARCHAR2(4) NOT NULL,
Suffix VARCHAR2(2) NOT NULL,
Abbreviation VARCHAR2(2) NOT NULL,
LongAcronym VARCHAR2(200) DEFAULT 'Undefined' NOT NULL,
Source VARCHAR2(10) NOT NULL,
EngineeringUnits VARCHAR2(10) NULL
);
CREATE UNIQUE INDEX IX_SignalType_ID ON SignalType (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE SignalType ADD CONSTRAINT PK_SignalType PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_SignalType START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_SignalType BEFORE INSERT ON SignalType
FOR EACH ROW BEGIN SELECT SEQ_SignalType.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Interconnection(
ID NUMBER NOT NULL,
Acronym VARCHAR2(50) NOT NULL,
Name VARCHAR2(100) NOT NULL,
LoadOrder NUMBER DEFAULT 0 NULL
);
CREATE UNIQUE INDEX IX_Interconnection_ID ON Interconnection (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Interconnection ADD CONSTRAINT PK_Interconnection PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Interconnection START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Interconnection BEFORE INSERT ON Interconnection
FOR EACH ROW BEGIN SELECT SEQ_Interconnection.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Node(
ID VARCHAR2(36) NOT NULL,
Name VARCHAR2(200) NOT NULL,
CompanyID NUMBER NULL,
Longitude NUMBER(9, 6) NULL,
Latitude NUMBER(9, 6) NULL,
Description VARCHAR2(4000) NULL,
ImagePath VARCHAR2(4000) NULL,
Settings VARCHAR2(4000) NULL,
MenuType VARCHAR2(200) DEFAULT 'File' NOT NULL,
MenuData VARCHAR2(4000) DEFAULT 'Menu.xml' NOT NULL,
Master NUMBER DEFAULT 0 NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Node_ID ON Node (ID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Node_Name ON Node (Name ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Node ADD CONSTRAINT PK_Node PRIMARY KEY (ID);
CREATE TABLE DataOperation(
NodeID VARCHAR2(36) NULL,
Description VARCHAR2(4000) NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
MethodName VARCHAR2(200) NOT NULL,
Arguments VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL
);
CREATE TABLE OtherDevice(
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
Name VARCHAR2(200) NULL,
IsConcentrator NUMBER DEFAULT 0 NOT NULL,
CompanyID NUMBER NULL,
VendorDeviceID NUMBER NULL,
Longitude NUMBER(9, 6) NULL,
Latitude NUMBER(9, 6) NULL,
InterconnectionID NUMBER NULL,
Planned NUMBER DEFAULT 0 NOT NULL,
Desired NUMBER DEFAULT 0 NOT NULL,
InProgress NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OtherDevice_ID ON OtherDevice (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OtherDevice ADD CONSTRAINT PK_OtherDevice PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OtherDevice START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OtherDevice BEFORE INSERT ON OtherDevice
FOR EACH ROW BEGIN SELECT SEQ_OtherDevice.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Device(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
ParentID NUMBER NULL,
UniqueID VARCHAR2(36) NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
Name VARCHAR2(200) NULL,
OriginalSource VARCHAR2(200) NULL,
IsConcentrator NUMBER DEFAULT 0 NOT NULL,
CompanyID NUMBER NULL,
HistorianID NUMBER NULL,
AccessID NUMBER DEFAULT 0 NOT NULL,
VendorDeviceID NUMBER NULL,
ProtocolID NUMBER NULL,
Longitude NUMBER(9, 6) NULL,
Latitude NUMBER(9, 6) NULL,
InterconnectionID NUMBER NULL,
ConnectionString VARCHAR2(4000) NULL,
TimeZone VARCHAR2(200) NULL,
FramesPerSecond NUMBER DEFAULT 30 NULL,
TimeAdjustmentTicks NUMBER(19, 0) DEFAULT 0 NOT NULL,
DataLossInterval NUMBER DEFAULT 5 NOT NULL,
AllowedParsingExceptions NUMBER DEFAULT 10 NOT NULL,
ParsingExceptionWindow NUMBER DEFAULT 5 NOT NULL,
DelayedConnectionInterval NUMBER DEFAULT 5 NOT NULL,
AllowUseOfCachedConfiguration NUMBER DEFAULT 1 NOT NULL,
AutoStartDataParsingSequence NUMBER DEFAULT 1 NOT NULL,
SkipDisableRealTimeData NUMBER DEFAULT 0 NOT NULL,
MeasurementReportingInterval NUMBER DEFAULT 100000 NOT NULL,
ConnectOnDemand NUMBER DEFAULT 1 NOT NULL,
ContactList VARCHAR2(4000) NULL,
MeasuredLines NUMBER NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Device_ID ON Device (ID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Device_UniqueID ON Device (UniqueID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Device_NodeID_Acronym ON Device (NodeID ASC, Acronym ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Device ADD CONSTRAINT PK_Device PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Device START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Device BEFORE INSERT ON Device
FOR EACH ROW BEGIN SELECT SEQ_Device.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE VendorDevice(
ID NUMBER NOT NULL,
VendorID NUMBER DEFAULT 10 NOT NULL,
Name VARCHAR2(200) NOT NULL,
Description VARCHAR2(4000) NULL,
URL VARCHAR2(4000) NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_VendorDevice_ID ON VendorDevice (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE VendorDevice ADD CONSTRAINT PK_VendorDevice PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_VendorDevice START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_VendorDevice BEFORE INSERT ON VendorDevice
FOR EACH ROW BEGIN SELECT SEQ_VendorDevice.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE OutputStreamDeviceDigital(
NodeID VARCHAR2(36) NOT NULL,
OutputStreamDeviceID NUMBER NOT NULL,
ID NUMBER NOT NULL,
Label VARCHAR2(4000) NOT NULL,
MaskValue NUMBER DEFAULT 0 NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OutStreamDevDigital_ID ON OutputStreamDeviceDigital (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OutputStreamDeviceDigital ADD CONSTRAINT PK_OutStreamDevDigital PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OutStreamDevDigital START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OutStreamDevDigital BEFORE INSERT ON OutputStreamDeviceDigital
FOR EACH ROW BEGIN SELECT SEQ_OutStreamDevDigital.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE OutputStreamDevicePhasor(
NodeID VARCHAR2(36) NOT NULL,
OutputStreamDeviceID NUMBER NOT NULL,
ID NUMBER NOT NULL,
Label VARCHAR2(200) NOT NULL,
Type CHAR(1) DEFAULT 'V' NOT NULL,
Phase CHAR(1) DEFAULT '+' NOT NULL,
ScalingValue NUMBER DEFAULT 0 NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OutStreamDevPhasor ON OutputStreamDevicePhasor (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OutputStreamDevicePhasor ADD CONSTRAINT PK_OutStreamDevPhasor PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OutStreamDevPhasor START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OutStreamDevPhasor BEFORE INSERT ON OutputStreamDevicePhasor
FOR EACH ROW BEGIN SELECT SEQ_OutStreamDevPhasor.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE OutputStreamDeviceAnalog(
NodeID VARCHAR2(36) NOT NULL,
OutputStreamDeviceID NUMBER NOT NULL,
ID NUMBER NOT NULL,
Label VARCHAR2(200) NOT NULL,
Type NUMBER DEFAULT 0 NOT NULL,
ScalingValue NUMBER DEFAULT 0 NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OutStreamDevAnalog ON OutputStreamDeviceAnalog (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OutputStreamDeviceAnalog ADD CONSTRAINT PK_OutStreamDevAnalog PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OutStreamDevAnalog START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OutStreamDevAnalog BEFORE INSERT ON OutputStreamDeviceAnalog
FOR EACH ROW BEGIN SELECT SEQ_OutStreamDevAnalog.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Measurement(
PointID NUMBER(19, 0) NOT NULL,
SignalID VARCHAR2(36) NOT NULL,
HistorianID NUMBER NULL,
DeviceID NUMBER NULL,
PointTag VARCHAR2(200) NOT NULL,
AlternateTag VARCHAR2(4000) NULL,
SignalTypeID NUMBER NOT NULL,
PhasorSourceIndex NUMBER NULL,
SignalReference VARCHAR2(200) NOT NULL,
Adder NUMBER DEFAULT 0.0 NOT NULL,
Multiplier NUMBER DEFAULT 1.0 NOT NULL,
Description VARCHAR2(4000) NULL,
Internal NUMBER DEFAULT 1 NOT NULL,
Subscribed NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Measurement_SignalID ON Measurement (SignalID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Measurement_PointID ON Measurement (PointID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Measurement ADD CONSTRAINT PK_Measurement PRIMARY KEY (SignalID);
ALTER TABLE Measurement ADD CONSTRAINT UQ_Measurement_PointID UNIQUE (PointID);
CREATE SEQUENCE SEQ_Measurement START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Measurement BEFORE INSERT ON Measurement
FOR EACH ROW BEGIN SELECT SEQ_Measurement.nextval INTO :NEW.PointID FROM dual;
END;
/
CREATE TABLE ImportedMeasurement(
NodeID VARCHAR2(36) NULL,
SourceNodeID VARCHAR2(36) NULL,
SignalID VARCHAR2(36) NULL,
Source VARCHAR2(200) NOT NULL,
PointID NUMBER(19, 0) NOT NULL,
PointTag VARCHAR2(200) NOT NULL,
AlternateTag VARCHAR2(200) NULL,
SignalTypeAcronym VARCHAR2(4) NULL,
SignalReference VARCHAR2(200) NOT NULL,
FramesPerSecond NUMBER NULL,
ProtocolAcronym VARCHAR2(200) NULL,
ProtocolType VARCHAR2(200) DEFAULT 'Frame' NOT NULL,
PhasorID NUMBER NULL,
PhasorType CHAR(1) NULL,
Phase CHAR(1) NULL,
Adder NUMBER DEFAULT 0.0 NOT NULL,
Multiplier NUMBER DEFAULT 1.0 NOT NULL,
CompanyAcronym VARCHAR2(200) NULL,
Longitude NUMBER(9, 6) NULL,
Latitude NUMBER(9, 6) NULL,
Description VARCHAR2(4000) NULL,
Enabled NUMBER DEFAULT 0 NOT NULL
);
CREATE TABLE Statistic(
ID NUMBER NOT NULL,
Source VARCHAR2(20) NOT NULL,
SignalIndex NUMBER NOT NULL,
Name VARCHAR2(200) NOT NULL,
Description VARCHAR2(4000) NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
MethodName VARCHAR2(200) NOT NULL,
Arguments VARCHAR2(4000) NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
DataType VARCHAR2(200) NULL,
DisplayFormat VARCHAR2(200) NULL,
IsConnectedState NUMBER DEFAULT 0 NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL
);
CREATE UNIQUE INDEX IX_Statistic_ID ON Statistic (ID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Statistic_Source_SigIndex ON Statistic (Source ASC, SignalIndex ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Statistic ADD CONSTRAINT PK_Statistic PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Statistic START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Statistic BEFORE INSERT ON Statistic
FOR EACH ROW BEGIN SELECT SEQ_Statistic.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE OutputStreamMeasurement(
NodeID VARCHAR2(36) NOT NULL,
AdapterID NUMBER NOT NULL,
ID NUMBER NOT NULL,
HistorianID NUMBER NULL,
PointID NUMBER(19, 0) NOT NULL,
SignalReference VARCHAR2(200) NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OutputStreamMeasurement_ID ON OutputStreamMeasurement (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OutputStreamMeasurement ADD CONSTRAINT PK_OutputStreamMeasurement PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OutputStreamMeasurement START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OutputStreamMeasurement BEFORE INSERT ON OutputStreamMeasurement
FOR EACH ROW BEGIN SELECT SEQ_OutputStreamMeasurement.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE OutputStreamDevice(
NodeID VARCHAR2(36) NOT NULL,
AdapterID NUMBER NOT NULL,
ID NUMBER NOT NULL,
IDCode NUMBER DEFAULT 0 NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
BpaAcronym VARCHAR2(4) NULL,
Name VARCHAR2(200) NOT NULL,
PhasorDataFormat VARCHAR2(15) NULL,
FrequencyDataFormat VARCHAR2(15) NULL,
AnalogDataFormat VARCHAR2(15) NULL,
CoordinateFormat VARCHAR2(15) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OutputStreamDevice_ID ON OutputStreamDevice (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OutputStreamDevice ADD CONSTRAINT PK_OutputStreamDevice PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OutputStreamDevice START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OutputStreamDevice BEFORE INSERT ON OutputStreamDevice
FOR EACH ROW BEGIN SELECT SEQ_OutputStreamDevice.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Phasor(
ID NUMBER NOT NULL,
DeviceID NUMBER NOT NULL,
Label VARCHAR2(200) NOT NULL,
Type CHAR(1) DEFAULT 'V' NOT NULL,
Phase CHAR(1) DEFAULT '+' NOT NULL,
DestinationPhasorID NUMBER NULL,
SourceIndex NUMBER DEFAULT 0 NOT NULL,
BaseKV NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Phasor_ID ON Phasor (ID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_Phasor_DeviceID_SrcIndex ON Phasor (DeviceID ASC, SourceIndex ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Phasor ADD CONSTRAINT PK_Phasor PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Phasor START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Phasor BEFORE INSERT ON Phasor
FOR EACH ROW BEGIN SELECT SEQ_Phasor.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE CalculatedMeasurement(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
Name VARCHAR2(200) NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
ConnectionString VARCHAR2(4000) NULL,
ConfigSection VARCHAR2(200) NULL,
InputMeasurements VARCHAR2(4000) NULL,
OutputMeasurements VARCHAR2(4000) NULL,
MinimumMeasurementsToUse NUMBER DEFAULT -1 NOT NULL,
FramesPerSecond NUMBER DEFAULT 30 NOT NULL,
LagTime NUMBER DEFAULT 3.0 NOT NULL,
LeadTime NUMBER DEFAULT 1.0 NOT NULL,
UseLocalClockAsRealTime NUMBER DEFAULT 0 NOT NULL,
AllowSortsByArrival NUMBER DEFAULT 1 NOT NULL,
IgnoreBadTimeStamps NUMBER DEFAULT 0 NOT NULL,
TimeResolution NUMBER DEFAULT 10000 NOT NULL,
AllowPreemptivePublishing NUMBER DEFAULT 1 NOT NULL,
PerformTimeReasonabilityCheck NUMBER DEFAULT 1 NOT NULL,
DownsamplingMethod VARCHAR2(15) DEFAULT 'LastReceived' NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_CalculatedMeasurement_ID ON CalculatedMeasurement (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE CalculatedMeasurement ADD CONSTRAINT PK_CalculatedMeasurement PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_CalculatedMeasurement START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_CalculatedMeasurement BEFORE INSERT ON CalculatedMeasurement
FOR EACH ROW BEGIN SELECT SEQ_CalculatedMeasurement.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE CustomActionAdapter(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
AdapterName VARCHAR2(200) NOT NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
ConnectionString VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_CustomActionAdapter_ID ON CustomActionAdapter (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE CustomActionAdapter ADD CONSTRAINT PK_CustomActionAdapter PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_CustomActionAdapter START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_CustomActionAdapter BEFORE INSERT ON CustomActionAdapter
FOR EACH ROW BEGIN SELECT SEQ_CustomActionAdapter.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Historian(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
Name VARCHAR2(200) NULL,
AssemblyName VARCHAR2(4000) NULL,
TypeName VARCHAR2(4000) NULL,
ConnectionString VARCHAR2(4000) NULL,
IsLocal NUMBER DEFAULT 1 NOT NULL,
MeasurementReportingInterval NUMBER DEFAULT 100000 NOT NULL,
Description VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Historian_ID ON Historian (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE Historian ADD CONSTRAINT PK_Historian PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Historian START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Historian BEFORE INSERT ON Historian
FOR EACH ROW BEGIN SELECT SEQ_Historian.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE CustomInputAdapter(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
AdapterName VARCHAR2(200) NOT NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
ConnectionString VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_CustomInputAdapter ON CustomInputAdapter (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE CustomInputAdapter ADD CONSTRAINT PK_CustomInputAdapter PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_CustomInputAdapter START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_CustomInputAdapter BEFORE INSERT ON CustomInputAdapter
FOR EACH ROW BEGIN SELECT SEQ_CustomInputAdapter.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE CustomFilterAdapter(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
AdapterName VARCHAR2(200) NOT NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
ConnectionString VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_CustomFilterAdapter ON CustomFilterAdapter (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE CustomFilterAdapter ADD CONSTRAINT PK_CustomFilterAdapter PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_CustomFilterAdapter START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_CustomFilterAdapter BEFORE INSERT ON CustomFilterAdapter
FOR EACH ROW BEGIN SELECT SEQ_CustomFilterAdapter.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE OutputStream(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
Acronym VARCHAR2(200) NOT NULL,
Name VARCHAR2(200) NULL,
Type NUMBER DEFAULT 0 NOT NULL,
ConnectionString VARCHAR2(4000) NULL,
DataChannel VARCHAR2(4000) NULL,
CommandChannel VARCHAR2(4000) NULL,
IDCode NUMBER DEFAULT 0 NOT NULL,
AutoPublishConfigFrame NUMBER DEFAULT 0 NOT NULL,
AutoStartDataChannel NUMBER DEFAULT 1 NOT NULL,
NominalFrequency NUMBER DEFAULT 60 NOT NULL,
FramesPerSecond NUMBER DEFAULT 30 NOT NULL,
LagTime NUMBER DEFAULT 3.0 NOT NULL,
LeadTime NUMBER DEFAULT 1.0 NOT NULL,
UseLocalClockAsRealTime NUMBER DEFAULT 0 NOT NULL,
AllowSortsByArrival NUMBER DEFAULT 1 NOT NULL,
IgnoreBadTimeStamps NUMBER DEFAULT 0 NOT NULL,
TimeResolution NUMBER DEFAULT 330000 NOT NULL,
AllowPreemptivePublishing NUMBER DEFAULT 1 NOT NULL,
PerformTimeReasonabilityCheck NUMBER DEFAULT 1 NOT NULL,
DownsamplingMethod VARCHAR2(15) DEFAULT 'LastReceived' NOT NULL,
DataFormat VARCHAR2(15) DEFAULT 'FloatingPoint' NOT NULL,
CoordinateFormat VARCHAR2(15) DEFAULT 'Polar' NOT NULL,
CurrentScalingValue NUMBER DEFAULT 2423 NOT NULL,
VoltageScalingValue NUMBER DEFAULT 2725785 NOT NULL,
AnalogScalingValue NUMBER DEFAULT 1373291 NOT NULL,
DigitalMaskValue NUMBER DEFAULT -65536 NOT NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_OutputStream_ID ON OutputStream (ID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_OutputStream_NodeID_Acronym ON OutputStream (NodeID ASC, Acronym ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE OutputStream ADD CONSTRAINT PK_OutputStream PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_OutputStream START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_OutputStream BEFORE INSERT ON OutputStream
FOR EACH ROW BEGIN SELECT SEQ_OutputStream.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE PowerCalculation(
NodeID VARCHAR2(36) NULL,
ID NUMBER NOT NULL,
CircuitDescription VARCHAR2(4000) NULL,
VoltageAngleSignalID VARCHAR2(36) NOT NULL,
VoltageMagSignalID VARCHAR2(36) NOT NULL,
CurrentAngleSignalID VARCHAR2(36) NOT NULL,
CurrentMagSignalID VARCHAR2(36) NOT NULL,
ActivePowerOutputSignalID VARCHAR2(36) NULL,
ReactivePowerOutputSignalID VARCHAR2(36) NULL,
ApparentPowerOutputSignalID VARCHAR2(36) NULL,
Enabled NUMBER NOT NULL
);
CREATE UNIQUE INDEX IX_PowerCalculation_ID ON PowerCalculation (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE PowerCalculation ADD CONSTRAINT PK_PowerCalculation PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_PowerCalculation START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_PowerCalculation BEFORE INSERT ON PowerCalculation
FOR EACH ROW BEGIN SELECT SEQ_PowerCalculation.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE Alarm(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
TagName VARCHAR2(200) NOT NULL,
SignalID VARCHAR2(36) NOT NULL,
AssociatedMeasurementID VARCHAR2(36) NULL,
Description VARCHAR2(4000) NULL,
Severity NUMBER NOT NULL,
Operation NUMBER NOT NULL,
SetPoint NUMBER NULL,
Tolerance NUMBER NULL,
Delay NUMBER NULL,
Hysteresis NUMBER NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_Alarm_ID ON Alarm (ID ASC) TABLESPACE openPDC_INDEX;
CREATE INDEX IX_Alarm_TagName ON Alarm (TagName ASC) TABLESPACE GSFShema_INDEX;
ALTER TABLE Alarm ADD CONSTRAINT PK_Alarm PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_Alarm START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_Alarm BEFORE INSERT ON Alarm
FOR EACH ROW BEGIN SELECT SEQ_Alarm.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE AlarmLog(
ID NUMBER NOT NULL,
SignalID VARCHAR2(36) NOT NULL,
PreviousState NUMBER NULL,
NewState NUMBER NULL,
Ticks NUMBER(19, 0) NOT NULL,
Timestamp TIMESTAMP NOT NULL,
Value NUMBER NOT NULL
);
CREATE UNIQUE INDEX IX_AlarmLog_ID ON AlarmLog (ID ASC) TABLESPACE openPDC_INDEX;
CREATE INDEX IX_AlarmLog_SignalID ON AlarmLog (SignalID ASC) TABLESPACE openPDC_INDEX;
CREATE INDEX IX_AlarmLog_PreviousState ON AlarmLog (PreviousState ASC) TABLESPACE openPDC_INDEX;
CREATE INDEX IX_AlarmLog_NewState ON AlarmLog (NewState ASC) TABLESPACE openPDC_INDEX;
CREATE INDEX IX_AlarmLog_Timestamp ON AlarmLog (Timestamp ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE AlarmLog ADD CONSTRAINT PK_AlarmLog PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_AlarmLog START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_AlarmLog BEFORE INSERT ON AlarmLog
FOR EACH ROW BEGIN SELECT SEQ_AlarmLog.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE CustomOutputAdapter(
NodeID VARCHAR2(36) NOT NULL,
ID NUMBER NOT NULL,
AdapterName VARCHAR2(200) NOT NULL,
AssemblyName VARCHAR2(4000) NOT NULL,
TypeName VARCHAR2(4000) NOT NULL,
ConnectionString VARCHAR2(4000) NULL,
LoadOrder NUMBER DEFAULT 0 NOT NULL,
Enabled NUMBER DEFAULT 0 NOT NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_CustomOutputAdapter_ID ON CustomOutputAdapter (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE CustomOutputAdapter ADD CONSTRAINT PK_CustomOutputAdapter PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_CustomOutputAdapter START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_CustomOutputAdapter BEFORE INSERT ON CustomOutputAdapter
FOR EACH ROW BEGIN SELECT SEQ_CustomOutputAdapter.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE AccessLog (
ID NUMBER NOT NULL,
UserName VARCHAR2(200) NOT NULL,
AccessGranted NUMBER NOT NULL,
NodeID VARCHAR2(36) NOT NULL,
CreatedOn DATE NOT NULL
);
CREATE UNIQUE INDEX IX_AccessLog_ID ON AccessLog (ID ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE AccessLog ADD CONSTRAINT PK_AccessLog PRIMARY KEY (ID);
CREATE SEQUENCE SEQ_AccessLog START WITH 1 INCREMENT BY 1;
CREATE TRIGGER AI_AccessLog BEFORE INSERT ON AccessLog
FOR EACH ROW BEGIN SELECT SEQ_AccessLog.nextval INTO :NEW.ID FROM dual;
END;
/
CREATE TABLE UserAccount (
ID VARCHAR2(36) NOT NULL,
Name VARCHAR2(200) NOT NULL,
Password VARCHAR2(200) NULL,
FirstName VARCHAR2(200) NULL,
LastName VARCHAR2(200) NULL,
DefaultNodeID VARCHAR2(36) NOT NULL,
Phone VARCHAR2(200) NULL,
Email VARCHAR2(200) NULL,
LockedOut NUMBER DEFAULT 0 NOT NULL,
UseADAuthentication NUMBER DEFAULT 1 NOT NULL,
ChangePasswordOn DATE NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_UserAccount_ID ON UserAccount (ID ASC) TABLESPACE openPDC_INDEX;
CREATE UNIQUE INDEX IX_UserAccount_Name ON UserAccount (Name ASC) TABLESPACE openPDC_INDEX;
ALTER TABLE UserAccount ADD CONSTRAINT PK_UserAccount PRIMARY KEY (ID);
CREATE TABLE SecurityGroup (
ID VARCHAR2(36) NOT NULL,
Name VARCHAR2(200) NOT NULL,
Description VARCHAR2(4000) NULL,
CreatedOn DATE NOT NULL,
CreatedBy VARCHAR2(200) NOT NULL,
UpdatedOn DATE NOT NULL,
UpdatedBy VARCHAR2(200) NOT NULL
);
CREATE UNIQUE INDEX IX_SecurityGroup_ID ON SecurityGroup (ID ASC) TABLESPACE openPDC_INDEX;