BMW Wallbox (Delta Electronics) — Full Capability Report

Results from a full OCPP 2.0.1 GetBaseReport(FullInventory) dump performed on 2026-04-11.

Charge Point ID: DE*BMW*EXXXXXXXXXXXXXXXXX Firmware: 01.20.06.71 Connection: WiFi, OCPP 2.0.1 over WSS, Security Profile 2


Measurands Available

The wallbox only supports 4 measurands via SampledDataCtrlr:

Measurand Supported
Current.Import Yes
Energy.Active.Import.Register Yes
Power.Active.Import Yes
Voltage Yes
SoC No
Frequency No
Temperature No
Power.Factor No
Power.Active.Export No
Power.Reactive.* No
Energy.Active.Export.* No
Energy.Reactive.* No
Current.Export No
Current.Offered No

All other measurands defined in OCPP 2.0.1 MeasurandEnumType are not available on this hardware.

ISO 15118 Support

Minimal. The ISO15118Ctrlr component exists but only exposes one variable:

Variable Status Value
CentralContractValidationAllowed Accepted false
PnCEnabled UnknownVariable
V2GCertificateInstallationEnabled UnknownVariable
ContractValidationOffline UnknownVariable
ContractCertificateInstallationEnabled UnknownVariable
RequestMeteringReceipt UnknownVariable
ISO15118EvseId UnknownVariable
CountryName UnknownVariable
OrganizationName UnknownVariable
MaxScheduleTuples UnknownVariable

Conclusion: No Plug & Charge, no ISO 15118 vehicle communication. The wallbox cannot receive vehicle data (brand, model, battery capacity, SoC) from the car. AC charging uses basic IEC 61851 pilot signal only.

Why Public Chargers Show Battery %

Public chargers that display SoC typically use:

  1. DC (CCS/CHAdeMO) — mandatory PLC communication where the car sends battery data
  2. Backend/app — the user's account has the car registered (brand, model, license plate)
  3. ISO 15118 Plug & Charge — certificate exchange identifies the contract, not the car itself

This BMW Wallbox (AC, no PnC) has no mechanism to receive car data via the cable. For vehicle info (SoC, model, battery), use the BMW Connected Drive integration or similar cloud APIs.

Full Inventory

ChargingStation

Variable Value Mutability
Available true ReadOnly
AvailabilityState Occupied ReadOnly
SupplyPhases 1 ReadOnly
Power 6584 W (max 7360 W) ReadOnly
ACCurrent 30 A (max 32 A) ReadOnly
ACVoltage 216 V (max 230 V) ReadOnly
FirmwareVersion 01.20.06.71 ReadOnly
GridType TN (options: TN, TT, IT) ReadOnly
GMIstatus true ReadOnly
MaxCurrent 32 A ReadOnly
Country PT ReadWrite
InstallationComplete true ReadOnly

EVSE (id=1)

Variable Value Mutability
Available true ReadOnly
AvailabilityState Occupied ReadOnly
SupplyPhases 1 ReadOnly
Power 6548 W (max 7360 W) ReadOnly
ACVoltage 215 V (max 230 V) ReadWrite
ACCurrent 30 A (max 32 A) ReadWrite

Connector (EVSE 1, Connector 1)

Variable Value Mutability
Available true ReadOnly
AvailabilityState Occupied ReadOnly

AuthCtrlr

Variable Value Mutability
Enabled false ReadWrite
OfflineTxForUnknownIdEnabled false ReadWrite
AuthorizeRemoteStart false ReadWrite
LocalAuthorizeOffline true ReadWrite
LocalPreAuthorize false ReadWrite

AuthCtrlr (MBA instance)

Variable Value Mutability
Enabled true ReadWrite

LocalAuthListCtrlr

Variable Value Mutability
Enabled false ReadWrite
Entries 0 (max 32) ReadOnly
ItemsPerMessage 8 ReadOnly
BytesPerMessage 2048 ReadOnly
Storage 8192 ReadOnly
SetupCardIdToken (redacted) ReadWrite
ListContent (redacted) ReadWrite

TxCtrlr

Variable Value Mutability
EVConnectionTimeOut 60 s ReadWrite
StopTxOnEVSideDisconnect true ReadOnly
TxBeforeAcceptedEnabled true ReadWrite
TxStartPoint EVConnected,Authorized,EnergyTransfer ReadWrite
TxStopPoint PowerPathClosed ReadWrite
StopTxOnInvalidId true ReadWrite

SampledDataCtrlr

Variable Value Mutability
TxEndedMeasurands Energy.Active.Import.Register ReadWrite
TxEndedInterval 0 s ReadWrite
TxStartedMeasurands Energy.Active.Import.Register ReadWrite
TxUpdatedMeasurands Energy.Active.Import.Register ReadWrite
TxUpdatedInterval 0 s ReadWrite

Available measurands: Current.Import, Energy.Active.Import.Register, Power.Active.Import, Voltage

AlignedDataCtrlr

Variable Value Mutability
Enabled false ReadWrite
Available false ReadOnly
SendDuringIdle true ReadWrite
SignReadings false ReadWrite

SmartChargingCtrlr

Variable Value Mutability
Enabled true ReadWrite
ACPhaseSwitchingSupported false ReadOnly
ProfileStackLevel 5 ReadOnly
RateUnit A, W ReadOnly
PeriodsPerSchedule 33 ReadOnly
ExternalControlSignalsEnabled false ReadOnly
NotifyChargingLimitWithSchedules false ReadWrite
Phases3to1 false ReadOnly
Entries (ChargingProfiles) 15 ReadOnly
LimitChangeSignificance 0.0 ReadWrite

LocalSmartChargingCtrlr

Instance Variable Value Mutability
ChargingPowerLimited false ReadWrite
DLC MinTimeOff 1 min (1-30) ReadWrite
DLC CurrentSafeLLM 0 A (0-10) ReadWrite
DLC CurrentSafeSLM 0 A (0-20) ReadWrite
DLC Enabled false ReadWrite
PV ChargingMode direct (direct/manual/strict) ReadWrite
PV MinimumCurrent 6 A (6-32) ReadWrite
PV Enabled false ReadWrite
PeakShifting MinTimeOff 1 min (1-30) ReadWrite
PeakShifting Enabled true ReadWrite
ScheduledCharging Enabled true ReadWrite

ExternalMeteringCtrlr (SmartMeter1)

Variable Value Mutability
ModelName Janitza B23 312-10J ReadOnly
BaudRate 19200 ReadOnly
ParityCheck none ReadOnly
Address 1 (Modbus) ReadOnly
PhaseOrder L1SM-L1WB ReadOnly
Enabled false ReadOnly
PowerActive (Sum) 0 W ReadOnly
ActiveEnergy (Total) 0 Wh ReadOnly
SamplingRate 1 s ReadWrite
NumSampleAvg 1 s ReadWrite

MeteringCtrlr (Aggregation)

5-minute aggregated power data:

Variable Value
Period Length 300 s
Period Start 2026-04-11T15:24:00Z
Period End 2026-04-11T15:29:00Z
HouseholdPowerActive Avg 0 W
HouseholdPowerActive Min 0 W
HouseholdPowerActive Max 0 W
ChargerPowerActive Avg 6506.5 W
ChargerPowerActive Min 6436.1 W
ChargerPowerActive Max 6586.5 W

SecurityCtrlr

Variable Value Mutability
BasicAuthPassword (WriteOnly) WriteOnly
SecurityProfile 2 ReadOnly
AdditionalRootCertificateCheck false ReadOnly

OCPPCommCtrlr

Variable Value Mutability
MessageTimeout 30 s ReadOnly
HeartbeatInterval 10 s ReadWrite
NetworkConfigurationPriority 0 ReadWrite
NetworkProfileConnectionAttempts 3 ReadWrite
OfflineThreshold 3600 s ReadWrite
QueueAllMessages true ReadWrite
MessageAttempts (TransactionEvent) 3 ReadWrite
MessageAttemptInterval (TransactionEvent) 60 s ReadWrite
WebSocketPingInterval 300 s ReadWrite
RetryBackOffRepeatTimes 3 ReadWrite
RetryBackOffRandomRange 5 s ReadWrite
RetryBackOffWaitMinimum 15 s ReadWrite

NetworkingCtrlr

Variable Value
ActiveConnection wifi
LAN configured false
WiFi configured true
Mobile configured false

Other

Component Variable Value
MainCircuitBreaker MaxCurrent 100 A
StatusLED brightness 30
ClockCtrlr TimeAdjustmentReportingThreshold 20
RandomDelayCtrlr Min 0 s
RandomDelayCtrlr Max 0 s

TriggerMessage Support

Message Status
BootNotification Rejected
MeterValues Accepted
StatusNotification Rejected
TransactionEvent Accepted

What Cannot Be Done

  • Get vehicle SoC — not in measurands, no ISO 15118 communication
  • Get vehicle brand/model/battery — no mechanism in OCPP or ISO 15118 on this hardware
  • Get frequency, temperature, power factor — not supported by the meter
  • Phase switching — ACPhaseSwitchingSupported = false (single phase only)
  • Trigger BootNotification/StatusNotification — wallbox rejects these triggers