You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
BMW Wallbox (Delta Electronics) — Full Capability Report
Results from a full OCPP 2.0.1 GetBaseReport(FullInventory) dump performed on 2026-04-11.
Charge Point ID:DE*BMW*EXXXXXXXXXXXXXXXXXFirmware:01.20.06.71Connection: WiFi, OCPP 2.0.1 over WSS, Security Profile 2
Measurands Available
The wallbox only supports 4 measurands via SampledDataCtrlr:
Measurand
Supported
Current.Import
Yes
Energy.Active.Import.Register
Yes
Power.Active.Import
Yes
Voltage
Yes
SoC
No
Frequency
No
Temperature
No
Power.Factor
No
Power.Active.Export
No
Power.Reactive.*
No
Energy.Active.Export.*
No
Energy.Reactive.*
No
Current.Export
No
Current.Offered
No
All other measurands defined in OCPP 2.0.1 MeasurandEnumType are not available on this hardware.
ISO 15118 Support
Minimal. The ISO15118Ctrlr component exists but only exposes one variable:
Variable
Status
Value
CentralContractValidationAllowed
Accepted
false
PnCEnabled
UnknownVariable
—
V2GCertificateInstallationEnabled
UnknownVariable
—
ContractValidationOffline
UnknownVariable
—
ContractCertificateInstallationEnabled
UnknownVariable
—
RequestMeteringReceipt
UnknownVariable
—
ISO15118EvseId
UnknownVariable
—
CountryName
UnknownVariable
—
OrganizationName
UnknownVariable
—
MaxScheduleTuples
UnknownVariable
—
Conclusion: No Plug & Charge, no ISO 15118 vehicle communication. The wallbox cannot receive vehicle data (brand, model, battery capacity, SoC) from the car. AC charging uses basic IEC 61851 pilot signal only.
Why Public Chargers Show Battery %
Public chargers that display SoC typically use:
DC (CCS/CHAdeMO) — mandatory PLC communication where the car sends battery data
Backend/app — the user's account has the car registered (brand, model, license plate)
ISO 15118 Plug & Charge — certificate exchange identifies the contract, not the car itself
This BMW Wallbox (AC, no PnC) has no mechanism to receive car data via the cable. For vehicle info (SoC, model, battery), use the BMW Connected Drive integration or similar cloud APIs.
Full Inventory
ChargingStation
Variable
Value
Mutability
Available
true
ReadOnly
AvailabilityState
Occupied
ReadOnly
SupplyPhases
1
ReadOnly
Power
6584 W (max 7360 W)
ReadOnly
ACCurrent
30 A (max 32 A)
ReadOnly
ACVoltage
216 V (max 230 V)
ReadOnly
FirmwareVersion
01.20.06.71
ReadOnly
GridType
TN (options: TN, TT, IT)
ReadOnly
GMIstatus
true
ReadOnly
MaxCurrent
32 A
ReadOnly
Country
PT
ReadWrite
InstallationComplete
true
ReadOnly
EVSE (id=1)
Variable
Value
Mutability
Available
true
ReadOnly
AvailabilityState
Occupied
ReadOnly
SupplyPhases
1
ReadOnly
Power
6548 W (max 7360 W)
ReadOnly
ACVoltage
215 V (max 230 V)
ReadWrite
ACCurrent
30 A (max 32 A)
ReadWrite
Connector (EVSE 1, Connector 1)
Variable
Value
Mutability
Available
true
ReadOnly
AvailabilityState
Occupied
ReadOnly
AuthCtrlr
Variable
Value
Mutability
Enabled
false
ReadWrite
OfflineTxForUnknownIdEnabled
false
ReadWrite
AuthorizeRemoteStart
false
ReadWrite
LocalAuthorizeOffline
true
ReadWrite
LocalPreAuthorize
false
ReadWrite
AuthCtrlr (MBA instance)
Variable
Value
Mutability
Enabled
true
ReadWrite
LocalAuthListCtrlr
Variable
Value
Mutability
Enabled
false
ReadWrite
Entries
0 (max 32)
ReadOnly
ItemsPerMessage
8
ReadOnly
BytesPerMessage
2048
ReadOnly
Storage
8192
ReadOnly
SetupCardIdToken
(redacted)
ReadWrite
ListContent
(redacted)
ReadWrite
TxCtrlr
Variable
Value
Mutability
EVConnectionTimeOut
60 s
ReadWrite
StopTxOnEVSideDisconnect
true
ReadOnly
TxBeforeAcceptedEnabled
true
ReadWrite
TxStartPoint
EVConnected,Authorized,EnergyTransfer
ReadWrite
TxStopPoint
PowerPathClosed
ReadWrite
StopTxOnInvalidId
true
ReadWrite
SampledDataCtrlr
Variable
Value
Mutability
TxEndedMeasurands
Energy.Active.Import.Register
ReadWrite
TxEndedInterval
0 s
ReadWrite
TxStartedMeasurands
Energy.Active.Import.Register
ReadWrite
TxUpdatedMeasurands
Energy.Active.Import.Register
ReadWrite
TxUpdatedInterval
0 s
ReadWrite
Available measurands:Current.Import, Energy.Active.Import.Register, Power.Active.Import, Voltage
AlignedDataCtrlr
Variable
Value
Mutability
Enabled
false
ReadWrite
Available
false
ReadOnly
SendDuringIdle
true
ReadWrite
SignReadings
false
ReadWrite
SmartChargingCtrlr
Variable
Value
Mutability
Enabled
true
ReadWrite
ACPhaseSwitchingSupported
false
ReadOnly
ProfileStackLevel
5
ReadOnly
RateUnit
A, W
ReadOnly
PeriodsPerSchedule
33
ReadOnly
ExternalControlSignalsEnabled
false
ReadOnly
NotifyChargingLimitWithSchedules
false
ReadWrite
Phases3to1
false
ReadOnly
Entries (ChargingProfiles)
15
ReadOnly
LimitChangeSignificance
0.0
ReadWrite
LocalSmartChargingCtrlr
Instance
Variable
Value
Mutability
—
ChargingPowerLimited
false
ReadWrite
DLC
MinTimeOff
1 min (1-30)
ReadWrite
DLC
CurrentSafeLLM
0 A (0-10)
ReadWrite
DLC
CurrentSafeSLM
0 A (0-20)
ReadWrite
DLC
Enabled
false
ReadWrite
PV
ChargingMode
direct (direct/manual/strict)
ReadWrite
PV
MinimumCurrent
6 A (6-32)
ReadWrite
PV
Enabled
false
ReadWrite
PeakShifting
MinTimeOff
1 min (1-30)
ReadWrite
PeakShifting
Enabled
true
ReadWrite
ScheduledCharging
Enabled
true
ReadWrite
ExternalMeteringCtrlr (SmartMeter1)
Variable
Value
Mutability
ModelName
Janitza B23 312-10J
ReadOnly
BaudRate
19200
ReadOnly
ParityCheck
none
ReadOnly
Address
1 (Modbus)
ReadOnly
PhaseOrder
L1SM-L1WB
ReadOnly
Enabled
false
ReadOnly
PowerActive (Sum)
0 W
ReadOnly
ActiveEnergy (Total)
0 Wh
ReadOnly
SamplingRate
1 s
ReadWrite
NumSampleAvg
1 s
ReadWrite
MeteringCtrlr (Aggregation)
5-minute aggregated power data:
Variable
Value
Period Length
300 s
Period Start
2026-04-11T15:24:00Z
Period End
2026-04-11T15:29:00Z
HouseholdPowerActive Avg
0 W
HouseholdPowerActive Min
0 W
HouseholdPowerActive Max
0 W
ChargerPowerActive Avg
6506.5 W
ChargerPowerActive Min
6436.1 W
ChargerPowerActive Max
6586.5 W
SecurityCtrlr
Variable
Value
Mutability
BasicAuthPassword
(WriteOnly)
WriteOnly
SecurityProfile
2
ReadOnly
AdditionalRootCertificateCheck
false
ReadOnly
OCPPCommCtrlr
Variable
Value
Mutability
MessageTimeout
30 s
ReadOnly
HeartbeatInterval
10 s
ReadWrite
NetworkConfigurationPriority
0
ReadWrite
NetworkProfileConnectionAttempts
3
ReadWrite
OfflineThreshold
3600 s
ReadWrite
QueueAllMessages
true
ReadWrite
MessageAttempts (TransactionEvent)
3
ReadWrite
MessageAttemptInterval (TransactionEvent)
60 s
ReadWrite
WebSocketPingInterval
300 s
ReadWrite
RetryBackOffRepeatTimes
3
ReadWrite
RetryBackOffRandomRange
5 s
ReadWrite
RetryBackOffWaitMinimum
15 s
ReadWrite
NetworkingCtrlr
Variable
Value
ActiveConnection
wifi
LAN configured
false
WiFi configured
true
Mobile configured
false
Other
Component
Variable
Value
MainCircuitBreaker
MaxCurrent
100 A
StatusLED
brightness
30
ClockCtrlr
TimeAdjustmentReportingThreshold
20
RandomDelayCtrlr
Min
0 s
RandomDelayCtrlr
Max
0 s
TriggerMessage Support
Message
Status
BootNotification
Rejected
MeterValues
Accepted
StatusNotification
Rejected
TransactionEvent
Accepted
What Cannot Be Done
Get vehicle SoC — not in measurands, no ISO 15118 communication
Get vehicle brand/model/battery — no mechanism in OCPP or ISO 15118 on this hardware
Get frequency, temperature, power factor — not supported by the meter