System Information
Windows 11 25H2
LMMS Version(s)
1.3.0-alpha.1.926+2db75bd
Most Recent Working Version
1.3.0-alpha.1.102+g89fc6c960
Bug Summary
When double clicking the volume controllers recently changed to the logarithmic scale, in "Set Value", the value is clamped to [-96, 6] and does not allow the full range supported by the controller. Throughout normal 0%-200% controllers, this bug is not so apparent, but in AudioFileProcessor, the full range is (-∞, 13.98] (500% in linear scale), which is impossible to type in the dialogue.
Expected Behaviour
The "Set Value" dialogue should clamp the min/max values according to the controller.
Steps To Reproduce
- Add an AudioFileProcessor instrument.
- Set gain to 500%/13.98 dB (the controller above the waveform).
- Double click the gain controller. The value gets clamped to 6 dB.
Logs
No response
Screenshots / Minimum Reproducible Project
No response
Please search the issue tracker for existing bug reports before submitting your own.
- I have searched all existing issues and confirmed that this is not a duplicate.