Skip to content

Wrong sigma matrix with Crab Cavities  #1228

@JoschD

Description

@JoschD

When activating the crab cavities, the calculation of the sigma matrix (SIG11 - SIG66) seems to be wrong,
e.g. beta_x * emittance_x != sig_11 , for small (i.e. LHC-like ex<1e-5, as compared to ex=1 - the latter seems ok) emittances.

It might be because activating the crab cavities causes twiss to run in 6D,
while the twiss for which this works runs in 4D.
It should be tested if "simply" switching the twiss to 6D also throws the values off.

Thanks to @tpersson who helped me investigate issue.

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions