ADR-0007: Efficiency-aware placement closes the measure-actuate loop

Status: Accepted Date: 2026-07-17

Context

The project currently has a measurement system and an actuation system that do not talk to each other. inferscope measures the two decisive metrics — tokens/joule via the NVML energy counter (ADR-010) and KV-cache hit-rate via the vLLM Prometheus scrape (ADR-011), extended to trajectory granularity by ADR-013 — and the operator places, protects, and recovers vLLM services on GPU fleets (ADR-0003..0006). The signals end in Grafana dashboards; the placement decisions are made without them. This ADR closes that loop.

Why the loop is worth closing is already quantified by our own experiments. Cache-regime shifts move an agentic workload's energy efficiency by up to -69.2% tokens/joule (18/18 matrix, Qwen2.5-32B, H100, agentic-kv-energy-experiment), and ADR-0006 concluded from that number that "orchestration policy is energy policy". The conclusion so far only shaped protection (per-role warmth and recovery). It has not yet shaped selection: when two nodes can host a service, the operator picks by warmth, utilization, and service count (fleet_placement.rs::NodeCandidate), blind to which node is running in an efficient cache regime and which is burning joules per token.

The actuation surface is already prepared for this. Placement is a pure function over NodeCandidate values, testable without a cluster (ADR-0003). Anti-oscillation guardrails exist in the API (HysteresisSpec: stableReconcilesRequired, maxConcurrentReschedules). Observed node state already flows through a per-node reporter into NodeState.status at a bounded cadence (default 15s), which today carries warmth, gpuUtilization, and spot status. Closing the loop is therefore an extension of three existing contracts, not a new subsystem.

Five decisions follow, D1-D5.

Decision

D1 — The loop actuates placement scoring, nothing else

Efficiency signals refine the ranking of candidate nodes inside the existing placement path. They do not drive replica autoscaling (HPA/KEDA territory, a different claim with a much larger risk surface) and they do not drive P/D role rebalancing (depends on the ADR-0006 implementation phases, which have not landed). Both are declared out of scope; the second is expected to become a follow-up once roles exist at runtime.

The resulting claim is deliberately narrow: energy- and cache-aware placement, closed-loop, measured. Placement is where the operator already has authority, a validated cost model, and a pure function to extend.

D2 — Signals ride the existing NodeState reporter contract

The per-node reporter publishes two new observed values in NodeState.status: tokensPerJoule (window-based) and kvCacheHitRate, both f32, same writer and cadence as the existing fields. inferscope remains the producer of the measurement — NVML energy sampling and the vllm:prefix_cache_* scrape are exactly ADR-010/011 — and the reporter consumes it locally rather than reimplementing it. The operator stays purely watch-driven: no Prometheus client, no query language, no coupling between loop availability and metrics-stack availability, and the placement function stays testable with synthetic candidates.

The demarcation line that also rejects reporter-side classification: status carries raw observed values (facts about the node); thresholds and quantization live in the planner (fleet policy). Warmth is a lifecycle state and belongs to the reporter; "what counts as efficient" depends on model and workload and belongs to FleetServiceSpec plus the pure function, where hysteresis already lives. The reporter has no opinions; the planner's opinions are configurable and testable.

Inherited limitation, stated explicitly: window-based attribution under controlled concurrency (ADR-013) makes per-node tokens/joule a reliable trend signal at window granularity, not per-request accounting. For ranking placement candidates that is sufficient.

D3 — Strict lexicographic ordering; warmth stays dominant

Signals enter as tie-breakers inside a warmth class, never across classes. Default ordering:

warmth > kvCacheHitRate > tokensPerJoule
       > gpuUtilization > activeServiceCount

The invariant survives intact by construction: a cold start costs minutes, an efficiency delta costs percentage points. Quantities of different orders of magnitude are ordered, not summed — which is also why a weighted composite score is rejected (it breaks the warmth-first guarantee, invites weight-tuning, and makes invariants untestable as properties). A threshold filter (exclude nodes below an efficiency floor) is rejected for v1 because a filter can shrink the candidate set until it forces a cold start; it is noted as a possible evolution once data exists on how hard a floor would bite.

Cache ranks before energy deliberately: agentic-kv shows the cache regime is the cause and tokens/joule the effect (H0→H2 monotone; the -69.2% is produced by regime shifts). Ordering on the effect after the cause avoids double-counting one phenomenon and keeps the ranking stable when tokens/joule fluctuates for reasons the cache already explains.

The ordering is policy, so it lives in PlacementSpec as a new PlacementStrategy variant (EfficiencyAware), the exact API-break absorption that enum was created for. WarmthFirst remains the default; existing FleetServices are untouched.

D4 — The loop acts only at natural decision points

Efficiency signals order candidates when a placement decision must be taken anyway — scale-up, recovery, spot reschedule. They never generate decisions: no running service is drained or migrated because a signal degraded.

The argument is quantitative, not cautious. The actuation cost of a migration is 57s to Ready in the best case (warm spare + modelCacheHostPath, item-4 evidence) plus 4-6 failed requests per event, and minutes in the cold case. The signal that would justify it is worth percentage points of a noisy window-based measure. The payback for proactive migration exists only under extreme, persistent degradation — a regime in which the node is likely failing for reasons the existing recovery path already intercepts. A loop that moves workload on small deltas of a noisy signal is the definition of oscillation.

Signal-triggered rebalancing is declared out of scope with its guardrails named, so the road is mapped rather than ignored: signal quantization, stableReconcilesRequired extended to efficiency signals, a minimum dwell time per placement, and the existing maxConcurrentReschedules cap. Until those exist, "closed-loop" here means: measure continuously, decide at the next actuation event — the same semantics warmth already has.

D5 — Scope and falsification

Out of scope for v1, explicitly:

  • Role-differentiated efficiency (P/D): depends on ADR-0006 phases 3-5; follow-up ADR once roles exist at runtime.
  • Any actuation on GPU power caps or frequencies: different actuator, different ADR.
  • Any interaction with InferencePool/EPP routing: endpoint-level energy-awareness belongs to the router layer (endpoint-attribute-scorer + customMetrics in llm-d make it pure configuration) and is complementary, not duplicated. Placement decides which node hosts a service; routing decides which endpoint serves a request. Two layers, two loops, kept distinct.

Falsification plan, three levels:

  1. Property tests on the pure function. The dominant invariant as a property, not an example: no combination of efficiency signals may ever rank a lower-warmth candidate above a higher-warmth one. Plus in-class ordering tests for the full lexicographic chain.
  2. Zero-cost kind rehearsal. A synthetic reporter writes NodeState objects with constructed signal patterns; assertions on the resulting placements. Nothing reaches a GPU node before this passes (standard session rule).
  3. GPU experiment (post 2026-08-11). 2-3 k3s nodes on Lambda, two nodes at equal warmth in different cache regimes (one serving a hot shared-prefix workload), EfficiencyAware vs WarmthFirst baseline, fleet-level tokens/joule, repeated runs, mean±std, same measurement windows as agentic-kv. Falsifiable claim: under mixed workload, cache/energy-aware placement improves fleet tokens/joule beyond run-to-run noise. If the delta is within noise, the null result is published as such — "the signal at this granularity is insufficient" is a finding, not a failure.

Consequences

  • NodeState.status grows tokensPerJoule and kvCacheHitRate (f32, raw observed values). The reporter gains a dependency on inferscope sampling; degraded mode is defined: if either signal is unavailable, the fields are absent and the planner ranks exactly as today. The loop fails open to current behaviour.
  • PlacementSpec.strategy gains the EfficiencyAware variant; WarmthFirst remains the default. No API break, no behaviour change for existing FleetServices.
  • The planner gains the lexicographic comparator and, with it, the home for future thresholds; hysteresis semantics are unchanged in v1.
  • Validation is sim-first on kind with a synthetic reporter, then one small GPU session (placement quality, not migration churn — a direct consequence of D4). Implementation and the GPU run are post-2026-08-11 blocks; this ADR is design only.
  • This ADR is the orchestration-side counterpart of inferscope ADR-013: trajectory-level attribution measures the economics, this loop acts on them. The agentic-kv article (go-live ~2026-08-11) gains a forward reference: the measured signal becomes a placement input.
  • Relation to ADR-0006: unchanged and single-role for now. When roles land, D1's rebalancing exclusion and D5's role exclusion are the two seams where a follow-up ADR plugs in.