Hall Current 20 Click

Hall Current 20 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.


Click Library

  • Author : Stefan Filipovic
  • Date : Oct 2024.
  • Type : ADC/I2C type

Software Support

Example Description

This example demonstrates the use of Hall Current 20 Click board by reading and displaying the input current measurements.

Example Libraries

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.HallCurrent20

Example Key Functions

  • hallcurrent20_cfg_setup Config Object Initialization function.
void hallcurrent20_cfg_setup ( hallcurrent20_cfg_t *cfg );
  • hallcurrent20_init Initialization function.
err_t hallcurrent20_init ( hallcurrent20_t *ctx, hallcurrent20_cfg_t *cfg );
  • hallcurrent20_calib_offset This function calibrates the zero current offset value.
err_t hallcurrent20_calib_offset ( hallcurrent20_t *ctx );
  • hallcurrent20_calib_resolution This function calibrates the data resolution at the known load current.
err_t hallcurrent20_calib_resolution ( hallcurrent20_t *ctx, float calib_current );
  • hallcurrent20_read_current This function reads the input current level [A].
err_t hallcurrent20_read_current ( hallcurrent20_t *ctx, float *current );

Application Init

Initializes the driver and calibrates the zero current offset and data resolution at 3A load current.

void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    hallcurrent20_cfg_t hallcurrent20_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    hallcurrent20_cfg_setup( &hallcurrent20_cfg );
    HALLCURRENT20_MAP_MIKROBUS( hallcurrent20_cfg, MIKROBUS_1 );
    if ( HALLCURRENT20_OK != hallcurrent20_init( &hallcurrent20, &hallcurrent20_cfg ) )
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    
    log_printf( &logger, " Calibrating zero current offset in 5 seconds...\r\n" );
    log_printf( &logger, " Make sure no current flows through the sensor during the calibration process.\r\n" );
    for ( uint8_t cnt = 5; cnt > 0; cnt-- )
    {
        log_printf( &logger, " %u\r\n", ( uint16_t ) cnt );
        Delay_ms ( 1000 );
    }
    if ( HALLCURRENT20_ERROR == hallcurrent20_calib_offset ( &hallcurrent20 ) )
    {
        log_error( &logger, " Calibrate offset." );
        for ( ; ; );
    }
    log_printf( &logger, " Offset calibration DONE.\r\n\n" );

    log_printf( &logger, " Calibrating data resolution in 5 seconds...\r\n" );
    log_printf( &logger, " Keep the load current set at %.1fA during the calibration process.\r\n", 
                HALLCURRENT20_CALIBRATING_CURRENT );
    for ( uint8_t cnt = 5; cnt > 0; cnt-- )
    {
        log_printf( &logger, " %u\r\n", ( uint16_t ) cnt );
        Delay_ms ( 1000 );
    }
    if ( HALLCURRENT20_ERROR == hallcurrent20_calib_resolution ( &hallcurrent20, HALLCURRENT20_CALIBRATING_CURRENT ) )
    {
        log_error( &logger, " Calibrate resolution." );
        for ( ; ; );
    }
    log_printf( &logger, " Data resolution calibration DONE.\r\n" );
    
    log_info( &logger, " Application Task " );
}

Application Task

Reads the input current measurements and displays the results on the USB UART approximately once per second.

void application_task ( void )
{
    float current = 0;
    if ( HALLCURRENT20_OK == hallcurrent20_read_current ( &hallcurrent20, &current ) ) 
    {
        log_printf( &logger, " Current : %.1f A\r\n\n", current );
        Delay_ms ( 1000 );
    }
}

Note

The measurement range is approximately: +/- 150A.

Application Output

This Click board can be interfaced and monitored in two ways:

  • Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
  • UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.

Additional Notes and Information

The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.