Hall Switch 3 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Nenad Filipovic
- Date : Nov 2023.
- Type : I2C type
This example demonstrates the use of Hall Switch 3 Click board by reading and displaying the magnetic field strength value.
- MikroSDK.Board
- MikroSDK.Log
- Click.HallSwitch3
hallswitch3_cfg_setup
Config Object Initialization function.
void hallswitch3_cfg_setup ( hallswitch3_cfg_t *cfg );
hallswitch3_init
Initialization function.
err_t hallswitch3_init ( hallswitch3_t *ctx, hallswitch3_cfg_t *cfg );
hallswitch3_default_cfg
Click Default Configuration function.
err_t hallswitch3_default_cfg ( hallswitch3_t *ctx );
hallswitch3_get_mag_data
This function is used to indicates a relative magnetic field strength.
err_t hallswitch3_get_mag_data ( hallswitch3_t *ctx, int8_t *mag_data );
hallswitch3_set_out_data_rate
This function provides the capability for the user to override the fixed sample rate controlling the sleep-compare-Vout cycle time.
err_t hallswitch3_set_out_data_rate ( hallswitch3_t *ctx, uint8_t odr );
hallswitch3_get_status
This function reads a status reporting of modes and selections.
err_t hallswitch3_get_status ( hallswitch3_t *ctx, uint8_t *status );
Initialization of I2C module and log UART. After driver initialization, the app executes a default configuration.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
hallswitch3_cfg_t hallswitch3_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
hallswitch3_cfg_setup( &hallswitch3_cfg );
HALLSWITCH3_MAP_MIKROBUS( hallswitch3_cfg, MIKROBUS_1 );
if ( I2C_MASTER_ERROR == hallswitch3_init( &hallswitch3, &hallswitch3_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( HALLSWITCH3_ERROR == hallswitch3_default_cfg ( &hallswitch3 ) )
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
This example demonstrates the use of the Hall Switch 3 Click board. The demo application reads and displays the relative magnetic field strength value [Gaussian units] and detects when the magnetic field strength is not in the configured range. The results are sent to the UART terminal, where you can monitor their changes.
void application_task ( void )
{
int8_t mag_data = 0;
if ( HALLSWITCH3_OK == hallswitch3_get_mag_data( &hallswitch3, &mag_data ) )
{
log_printf( &logger, " Magnetic Field: %d [Gs]\r\n", ( int16_t ) mag_data );
if ( HALLSWITCH3_OUT_STATE_LOW == hallswitch3_check_mag_field( &hallswitch3 ) )
{
log_printf( &logger, " The switch is open.\r\n" );
}
}
Delay_ms ( 1000 );
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.