Skip to content

Latest commit

 

History

History

hvac

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 
 
 

HVAC Click

HVAC Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.


Click Library

  • Author : Stefan Ilic
  • Date : Oct 2021.
  • Type : I2C type

Software Support

Example Description

This is an example that demonstrates the use of the HVAC Click board.

Example Libraries

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Hvac

Example Key Functions

  • hvac_cfg_setup Config Object Initialization function.
void hvac_cfg_setup ( hvac_cfg_t *cfg );
  • hvac_init Initialization function.
err_t hvac_init ( hvac_t *ctx, hvac_cfg_t *cfg );
  • hvac_sps30_start_measurement SPS30 start measurement command function.
void hvac_sps30_start_measurement ( hvac_t *ctx );
  • hvac_sps30_get_ready_flag SPS30 get ready flag function.
uint8_t hvac_sps30_get_ready_flag ( hvac_t *ctx );
  • hvac_sps30_read_measured_data SPS30 read measured data function.
void hvac_sps30_read_measured_data ( hvac_t *ctx, mass_and_num_cnt_data_t *m_n_c_data );

Application Init

Initialization driver enables - I2C, SCD40: perform factory reset, serial number, features, product type platform type, product version and SPS30: perform start measurement mode, also write log.

void application_init ( void ) 
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    hvac_cfg_t hvac_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    hvac_cfg_setup( &hvac_cfg );
    HVAC_MAP_MIKROBUS( hvac_cfg, MIKROBUS_1 );
    if ( I2C_MASTER_ERROR == hvac_init( &hvac, &hvac_cfg ) ) 
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    
    log_info( &logger, " Application Task " );
    Delay_ms ( 1000 );
    hvac_scd40_send_cmd( &hvac, HVAC_PERFORM_FACTORY_RESET );
    log_printf( &logger, "  Perform Factory Reset   \r\n" );
    log_printf( &logger, "--------------------------\r\n" );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );

    hvac_scd40_get_serial_number ( &hvac, ser_num );
    log_printf( &logger, "   SCD40 - Serial Number : %.4d-%.4d-%.4d \r\n", 
                ( uint16_t ) ser_num[ 0 ], ( uint16_t ) ser_num[ 1 ], ( uint16_t ) ser_num[ 2 ] );
    log_printf( &logger, "--------------------------\r\n" );
    Delay_ms ( 100 );
    hvac_scd40_get_feature_set_version( &hvac, &version_data );
    log_printf( &logger, "     SCD40 - Features     \r\n" );
    log_printf( &logger, " Product Type    : %d \r\n", ( uint16_t ) version_data.product_type );
    log_printf( &logger, " Platform Type   : %d \r\n", ( uint16_t ) version_data.platform_type );
    log_printf( &logger, " Product Version : %d.%d \r\n", 
                ( uint16_t ) version_data.product_major_version, 
                ( uint16_t ) version_data.product_minor_version );
    log_printf( &logger, "--------------------------\r\n" );
    Delay_ms ( 100 );
    
    hvac_sps30_start_measurement ( &hvac );
    Delay_ms ( 100 );
}

Application Task

This is an example which demonstrates the use of HVAC Click board. HVAC Click board can be used to measure : Concentration of CO2 in air, Temperature ( degree Celsius ), Relative Humidity ( % ), Mass Concentration of PM1.0, PM2.5, PM4.0, PM10 and Number Concentration of PM0.5, PM1.0, PM2.5, PM4.0 and PM10. All data logs write on USB uart changes.

void application_task ( void ) 
{
    hvac_scd40_send_cmd( &hvac, HVAC_MEASURE_SINGLE_SHOT );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    
    hvac_scd40_read_measurement( &hvac, &hvac_data );
    Delay_ms ( 100 );

    log_printf( &logger, " CO2 Concent = %d \r\n ", hvac_data.co2_concent );

    log_printf( &logger, " Temperature = %.2f C \r\n", hvac_data.temperature );

    log_printf( &logger, " R. Humidity = %.2f %% \r\n", hvac_data.r_humidity );
    log_printf( &logger, "- - - - - - - - - - - - -  \r\n" );
        
    while ( HVAC_SPS30_NEW_DATA_IS_READY != hvac_sps30_get_ready_flag( &hvac ) );
    
    
    log_printf( &logger, "   Mass Concentration :   \r\n" );
    hvac_sps30_read_measured_data( &hvac, &sps30_data );
    Delay_ms ( 100 );

    log_printf( &logger, " PM 1.0 = %.2f ug/m3 \r\n", sps30_data.mass_pm_1_0 );
    log_printf( &logger, " PM 2.5 = %.2f ug/m3 \r\n", sps30_data.mass_pm_2_5 );
    log_printf( &logger, " PM 4.0 = %.2f ug/m3 \r\n", sps30_data.mass_pm_4_0 );
    log_printf( &logger, " PM 10  = %.2f ug/m3 \r\n", sps30_data.mass_pm_10 );
    log_printf( &logger, "-   -   -   -   -   -   - \r\n" );

    log_printf( &logger, "  Number Concentration :  \r\n" );
    log_printf( &logger, " PM 0.5 = %.2f n/cm3 \r\n", sps30_data.num_pm_0_5 );
    log_printf( &logger, " PM 1.0 = %.2f n/cm3 \r\n", sps30_data.num_pm_1_0 );
    log_printf( &logger, " PM 2.5 = %.2f n/cm3 \r\n", sps30_data.num_pm_2_5 );
    log_printf( &logger, " PM 4.0 = %.2f n/cm3 \r\n", sps30_data.num_pm_4_0 );
    log_printf( &logger, " PM 10  = %.2f n/cm3 \r\n", sps30_data.num_pm_10 );
    log_printf( &logger, "--------------------------\r\n" );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
}

Application Output

This Click board can be interfaced and monitored in two ways:

  • Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
  • UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.

Additional Notes and Information

The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.