Step Down 6 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Stefan Ilic
- Date : May 2023.
- Type : I2C type
This library contains API for the Step Down 6 Click driver. This driver provides the functions to set the output voltage threshold.
- MikroSDK.Board
- MikroSDK.Log
- Click.StepDown6
stepdown6_cfg_setup
Config Object Initialization function.
void stepdown6_cfg_setup ( stepdown6_cfg_t *cfg );
stepdown6_init
Initialization function.
err_t stepdown6_init ( stepdown6_t *ctx, stepdown6_cfg_t *cfg );
stepdown6_default_cfg
Click Default Configuration function.
err_t stepdown6_default_cfg ( stepdown6_t *ctx );
stepdown6_set_en_pin
Step Down 6 set EN pin state function.
void stepdown6_set_en_pin ( stepdown6_t *ctx, uint8_t pin_state );
stepdown6_write_reg
Step Down 6 Register writing function.
err_t stepdown6_write_reg ( stepdown6_t *ctx, uint8_t reg, uint8_t data_in );
stepdown6_set_out_voltage
Step Down 6 Set output voltage function.
err_t stepdown6_set_out_voltage ( stepdown6_t *ctx, uint8_t out_sel, uint16_t out_val );
Initialization of I2C module and log UART. After driver initialization, default settings sets output voltage to 550 mV.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
stepdown6_cfg_t stepdown6_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
stepdown6_cfg_setup( &stepdown6_cfg );
STEPDOWN6_MAP_MIKROBUS( stepdown6_cfg, MIKROBUS_1 );
if ( I2C_MASTER_ERROR == stepdown6_init( &stepdown6, &stepdown6_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( STEPDOWN6_ERROR == stepdown6_default_cfg ( &stepdown6 ) )
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
This example demonstrates the use of the Step Down 6 Click board™ by changing output voltage every 5 seconds starting from 550 mV up to 1820 mV.
void application_task ( void )
{
err_t error_flag = STEPDOWN6_OK;
for ( uint16_t n_cnt = STEPDOWN6_MIN_VOUT_VAL; n_cnt <= STEPDOWN6_MAX_VOUT_VAL; n_cnt += STEPDOWN6_INCREMENT_VOUT_VAL )
{
error_flag |= stepdown6_set_out_voltage( &stepdown6, STEPDOWN6_SELECT_VOUT1, n_cnt );
error_flag |= stepdown6_set_out_voltage( &stepdown6, STEPDOWN6_SELECT_VOUT2, n_cnt );
error_flag |= stepdown6_set_out_voltage( &stepdown6, STEPDOWN6_SELECT_VOUT3, n_cnt );
error_flag |= stepdown6_set_out_voltage( &stepdown6, STEPDOWN6_SELECT_VOUT4, n_cnt );
log_printf( &logger, " Set voltage : %d mV \r\n", n_cnt );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.