From f1977bd9106fdeacd1b0161a8b320d89419300b7 Mon Sep 17 00:00:00 2001 From: Tor Harald Sandve Date: Thu, 6 Mar 2025 09:05:31 +0100 Subject: [PATCH] Add test case for item 9 in WECON --- wecon_wtest/3D_WECON_9.DATA | 229 ++++++++++++++++++++++++++++++++++++ 1 file changed, 229 insertions(+) create mode 100644 wecon_wtest/3D_WECON_9.DATA diff --git a/wecon_wtest/3D_WECON_9.DATA b/wecon_wtest/3D_WECON_9.DATA new file mode 100644 index 000000000..e598fd033 --- /dev/null +++ b/wecon_wtest/3D_WECON_9.DATA @@ -0,0 +1,229 @@ +-- This reservoir simulation deck is made available under the Open Database +-- License: http://opendatacommons.org/licenses/odbl/1.0/. Any rights in +-- individual contents of the database are licensed under the Database Contents +-- License: http://opendatacommons.org/licenses/dbcl/1.0/ + +-- Copyright (C) 2016 SINTEF ICT, Applied Mathematics +-- Copyright (C) 2016 Statoil +-- Copyright (C) 2018 IRIS +-- Copyright (C) 2025 Equinor + +-- Is modified from 3D_WECON to test opening of follow on wells (item 9 in WECON) + +RUNSPEC + +DIMENS +30 20 6/ + +GRIDOPTS + 'YES' 0 / + +OIL + +WATER + +GAS + +DISGAS + +VAPOIL + + +METRIC + + +START + 06 'NOV' 1997 / + +EQLDIMS +1 / +-- 5 100 20 / + +WELLDIMS + 130 36 15 84 / + + +TABDIMS +--ntsfun ntpvt nssfun nppvt ntfip nrpvt ntendp + 1 1 33 60 16 60 / + +REGDIMS +1 1 1 0 / + +PIMTDIMS +1 51 / + +NSTACK + 30 / + +UNIFIN +UNIFOUT + +--------------------------------------------------------- +-- +-- Input of grid geometry +-- +--------------------------------------------------------- +GRID + +NEWTRAN + +GRIDFILE + 2 / + +INIT + +NOECHO + +-------------------------------------------------------- +-- +-- Grid and faults +-- +-------------------------------------------------------- +INCLUDE + 'common/GRDECL.INC' / + +INCLUDE + 'common/ACTNUM.INC' / + +-------------------------------------------------------- +-- +-- Input of grid parametres +-- +-------------------------------------------------------- +INCLUDE + 'common/PORO.INC' / + +INCLUDE + 'common/PERMX.INC' / + +INCLUDE + 'common/PERMY.INC' / + +INCLUDE + 'common/PERMZ.INC' / + +-------------------------------------------------------------------------------- + +-------------------------------------------------------------------------------- + +PROPS + +INCLUDE + 'common/PROPS.INC' / + +NOECHO + + +--------------------------------------------------------------------------------- +SOLUTION + +EQUIL +-- Datum P woc Pc goc Pc Rsvd Rvvd + 2010 269.46 2120 0.0 2010.0 0.0 1* 0 0/ + +RPTSOL +FIP=3 SWAT SGAS PRESS SOIL / + +SUMMARY + +WOPR + 'PROD01' + 'PROD02' +/ + +WGPR + 'PROD01' + 'PROD02' +/ + +WBHP + 'INJE01' + 'PROD01' + 'PROD02' +/ + +WWIR + 'INJE01' +/ + +WWPR + 'PROD01' + 'PROD02' +/ + +WWCT + 'PROD01' + 'PROD02' +/ + +CWCT + 'PROD01' / + 'PROD02' / +/ + +COPR + 'PROD01' / + 'PROD02' / +/ +ALL +-------------------------------------------------------------------------------- + + +SCHEDULE + +RPTRST +BASIC=2 / + +NOECHO + +WELSPECS + 'INJE01' 'I' 13 10 1* 'WATER' / + 'PROD01' 'P' 24 16 1* 'OIL' 7* / + 'PROD02' 'P' 9 9 1* 'OIL' 7* / +/ + +COMPDAT + 'INJE01' 13 10 4 6 'OPEN' 1* 181.866 0.5 / + 'PROD01' 24 16 1 2 'OPEN' 1* 218.457 0.5 / + 'PROD02' 9 9 1 6 'OPEN' 1* 218.457 0.5 / +/ +COMPLUMP + 'PROD02' 2* 1 2 1/ + 'PROD02' 2* 3 4 2/ +/ + +WCONPROD + 'PROD01' 'OPEN' 'BHP' 5* 230 / + 'PROD02' 'SHUT' 'BHP' 5* 230 / +/ + +WECON + 'PROD01' 1000 4* WELL NO 'PROD02' / +-- 'PROD02' 1* 800 0.1 2* CON NO / +/ + +WTEST + 'PROD01' 100 E / +-- 'PROD02' 100 E / +/ + +WCONINJE + 'INJE01' 'WATER' 'OPEN' 'RATE' 250.00 1* 290 / +/ + +TSTEP +1 +3 +6 +10 +/ + +WCONINJE + 'INJE01' 'WATER' 'OPEN' 'RATE' 5000.00 1* 290 / +/ + +TSTEP +50*30 +/ +