Problem Statement

This document explains the problem that the Profile-Based Dual-Point Water Heater Controller is trying to solve.

Status: Design proposal
This project is not implemented yet.

Summary

ESPHome and Home Assistant already provide useful entities for temperature control, but there is currently a gap between:

  • water_heater: the correct domain for boilers and water heaters
  • climate: the stronger controller model for thermostat-like behavior

This project proposes a new ESPHome water_heater platform that keeps the correct water-heater domain while adding controller behavior designed for real electric boilers and multi-stage water heaters.

Current gap

Water heater domain

The water_heater domain is the correct semantic domain for boilers and domestic hot water systems.

However, current template-style water heater behavior is mostly entity-oriented:

  • current temperature
  • target temperature
  • operation mode
  • away mode
  • on/off state
  • set action

This is useful for representing a water heater, but it does not fully model a real boiler controller.

Missing concepts include:

  • explicit runtime action: heating, idle, waiting_for, error, off
  • heat-only dual-point low/high control
  • user-defined operating profiles
  • multi-stage heater output logic
  • interlock-based waiting states
  • physical output feedback validation
  • clear waiting and fault reasons

Climate thermostat domain

The climate thermostat platform provides stronger controller behavior, such as:

  • heating and idle actions
  • target-based control
  • anti-chatter timing
  • thermostat-like state management

But it uses the climate domain, which is semantically designed for space temperature and HVAC devices, not domestic water heaters.

For a boiler, this creates a mismatch:

Need climate thermostat water_heater
Correct water-heater domain No Yes
Heating / idle runtime behavior Yes Limited
Boiler-specific profiles No Limited
Heat-only dual-point water control Not ideal Not currently complete
Output feedback and interlocks Custom logic required Custom logic required

Real boiler requirements

A real electric boiler controller often needs more than a single target temperature.

Common requirements include:

1. Heat-only dual-point control

The controller should use a low/high target range:

Condition Result
Temperature <= target low Start heating
Temperature >= target high Stop heating
Temperature between low/high Keep previous demand state

The high target is the stop-heating point.

It is not a cooling point.

2. User-defined profiles

A boiler profile should describe a user-defined heating strategy.

Examples:

  • Economy
  • Balanced
  • Fast Recovery
  • Solar Only
  • Cheap Power
  • High Demand

The component should not hard-code profile names.

Each user should define their own profiles, icons, actions, interlocks, and expected outputs.

3. Multi-stage heater control

Many boilers may have more than one heating stage.

For example:

  • primary heater stage
  • assist heater stage
  • boost heater stage

Different profiles may use different stages.

Example:

Profile Expected heating stages
Economy Primary stage only
Balanced Primary + Assist
Fast Recovery Primary + Assist + Boost

4. Physical output feedback

A relay command does not prove that a heater stage actually started.

The controller should support real-world feedback such as:

  • contactor auxiliary contact
  • relay feedback
  • current sensor
  • binary sensor
  • power monitor

The controller should detect:

  • a required stage did not start
  • a stage did not stop
  • an unexpected stage is on

5. Interlocks and waiting reasons

Some conditions should block heating without being treated as faults.

Examples:

  • grid power unavailable
  • water level not safe
  • high-load permission not granted
  • solar power insufficient
  • cheap electricity window not active

When heating is blocked by these conditions, the controller should report:

action = waiting_for

and expose a human-readable reason.

Example:

waiting_reasons:
  - "Waiting for high load permission"

6. Explicit runtime actions

The controller should expose one clear runtime action:

off
idle
heating
waiting_for
error

These actions are fixed by the component.

They are not user-defined.

7. Clear separation of concepts

This project separates concepts that are often mixed together:

Concept Meaning
Power Whether the water heater is enabled
Profile User-defined heating strategy
Action Real runtime state calculated by the controller
Target range Low/high temperature control range
Interlock Temporary heating blocker
Feedback Real-world output confirmation
Fault Real failure requiring attention

Non-goals

This project does not aim to:

  • replace all existing ESPHome water heater platforms
  • replace the climate thermostat platform
  • force built-in profiles like ECO or Performance
  • treat off as a user-defined profile
  • use dual-point heat/cool HVAC semantics
  • hide real faults behind optimistic state updates
  • replace mechanical safety devices

Proposed solution

Add a new ESPHome water heater platform:

water_heater:
  - platform: profile_dual_point

The platform provides:

  • correct water_heater domain
  • user-defined profiles
  • heat-only dual-point control
  • multiple temperature sensors
  • interlocks with waiting reasons
  • monitored heater outputs
  • real output feedback validation
  • explicit runtime action
  • clear Home Assistant attributes

Why this should be a water_heater platform

This controller is intended for boilers and domestic water-heater systems.

The controlled medium is water, not room air.

The correct semantic entity in Home Assistant is therefore water_heater, not climate.

The goal is to bring thermostat-like control behavior into the water-heater domain without misusing the climate domain.

Expected outcome

A user should be able to create one water heater entity that clearly shows:

  • current tank temperature
  • target low/high range
  • selected profile
  • runtime action
  • waiting reasons
  • fault reasons
  • active heater stages
  • relevant temperature sensors

The end result should be a single official water-heater entity that can represent the real boiler state without requiring many separate helper entities.