You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
electrobiofuels,investment,517844.1334,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.2762,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.5773,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.2762,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,1086.877,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
electrobiofuels,investment,473961.8141,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.264,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.5874,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.264,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,792.5145,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
electrobiofuels,investment,431201.8155,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.2228,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.6217,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.2228,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,498.1519,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
electrobiofuels,investment,396566.0023,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.2039,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.6374,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.2039,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,441.5438,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
electrobiofuels,investment,362825.0124,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.1849,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.6532,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.1849,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,384.9356,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
electrobiofuels,investment,329978.8455,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.1571,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.6763,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.1571,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,328.3274,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
electrobiofuels,investment,298027.5019,EUR/kW_th,combination of BtL and electrofuels,
715
715
electrolysis,FOM,4.0,%/year,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Fixed O&M
716
-
electrolysis,efficiency,0.1294,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
716
+
electrolysis,efficiency,0.6994,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Hydrogen Output
717
717
electrolysis,efficiency-heat,0.1294,per unit,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: - hereof recoverable for district heating
718
718
electrolysis,investment,271.7192,EUR/kW_e,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Specific investment
719
719
electrolysis,lifetime,25.0,years,"Danish Energy Agency, data_sheets_for_renewable_fuels.xlsx",86 AEC 100 MW: Technical lifetime
0 commit comments