Skip to content

Commit 5544979

Browse files
authored
for central air-sourced heat pump use name plate efficiency (#142)
1 parent 56426aa commit 5544979

9 files changed

+18
-11
lines changed

docs/release_notes.rst

+6
Original file line numberDiff line numberDiff line change
@@ -5,6 +5,12 @@ Release Notes
55
.. Upcoming Release
66
.. ================
77
8+
9+
Technology-Data 0.9.2 (30 August 2024)
10+
======================================
11+
12+
* for central air-sourced heat pump use name plate efficiency
13+
814
Technology-Data 0.9.1 (7 August 2024)
915
=====================================
1016

outputs/costs_2020.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,3000000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2102,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.1,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,1006.7765,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

outputs/costs_2025.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,2800000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2102,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.15,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,1006.7765,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

outputs/costs_2030.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,2600000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.6561,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.6,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.2,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

outputs/costs_2035.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,2400000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.4868,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.625,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.25,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

outputs/costs_2040.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,2200000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.3175,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.65,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.3,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

outputs/costs_2045.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,2000000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.5715,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.675,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.35,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

outputs/costs_2050.csv

+1-1
Original file line numberDiff line numberDiff line change
@@ -633,7 +633,7 @@ cement capture,investment,1800000.0,EUR/(tCO2/h),"Danish Energy Agency, technolo
633633
cement capture,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_carbon_capture_transport_storage.xlsx",401.c Post comb - Cement kiln,2020.0
634634
central air-sourced heat pump,FOM,0.2336,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Fixed O&M",2015.0
635635
central air-sourced heat pump,VOM,2.8255,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Variable O&M",2015.0
636-
central air-sourced heat pump,efficiency,3.7,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency , net, annual average",2015.0
636+
central air-sourced heat pump,efficiency,3.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Total efficiency, net, name plate",2015.0
637637
central air-sourced heat pump,investment,906.0988,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Specific investment",2015.0
638638
central air-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, airsource 3 MW: Technical lifetime",2015.0
639639
central coal CHP,FOM,1.6316,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Fixed O&M,2015.0

scripts/compile_cost_assumptions.py

+5-4
Original file line numberDiff line numberDiff line change
@@ -1294,16 +1294,17 @@ def order_data(tech_data):
12941294
(df.unit =="MWh_e/MWh_th") |
12951295
(df.unit =="MWh_th/MWh_th") |
12961296
(df.unit =='MWh/MWh Total Input') |
1297-
df.unit.str.contains("MWh_FT/MWh_H2"))
1298-
& (~df.index.str.contains("name plate"))].copy()
1297+
df.unit.str.contains("MWh_FT/MWh_H2"))].copy()
12991298

13001299
if tech == 'Fischer-Tropsch':
13011300
efficiency[years] *= 100
13021301

13031302

1304-
# take annual average instead of name plate efficiency
1305-
if any(efficiency.index.str.contains("annual average")):
1303+
# take annual average instead of name plate efficiency, unless central air-sourced heat pump
1304+
if any(efficiency.index.str.contains("annual average")) and tech != "central air-sourced heat pump":
13061305
efficiency = efficiency[efficiency.index.str.contains("annual average")]
1306+
elif any(efficiency.index.str.contains("name plate")):
1307+
efficiency = efficiency[efficiency.index.str.contains("name plate")]
13071308

13081309
# hydrogen electrolysiswith recoverable heat
13091310
heat_recovery_label = "hereof recoverable for district heating"

0 commit comments

Comments
 (0)