Skip to content

Commit a1d7ca7

Browse files
Update central heat pumps (#153)
* feat: central split geothermal HPs in source and HP; add excess-heat and water-sourced HPs * feat: use upper uncertainty range for water-sourced heat pumps with inlet * doc: update release notes * docs: warn about splitting geothermal central heating into two technologies in release notes
1 parent 4efd377 commit a1d7ca7

9 files changed

+164
-16
lines changed

docs/release_notes.rst

+7-1
Original file line numberDiff line numberDiff line change
@@ -5,13 +5,19 @@ Release Notes
55
.. Upcoming Release
66
.. ================
77
8+
* added water-sourced heat pumps based on upper uncertainty bounds from DEA technology catalogue ("40 Comp. hp, seawater 20 MW")
9+
10+
* **WARNING**: Costs for central geothermal heating are split into `central geothermal heat source` and `central geothermal-sourced heat pump`. Make sure to use the costs of both for full systems!
11+
12+
* added geothermal district heating as `central geothermal-sourced heat pump` and `central goethermal heat source` based on DEA technology catalogue ("45.1.a Geothermal DH, 1200m, E")
13+
814
* added Pyrolysis for biochar
915

1016
* fixed unit formatting in DEA technology data sheets 105 (slow pyrolysis)
1117

1218
* fixed DEA technology data sheet name for central water tank storage to point to actual PTES data
1319

14-
* added geothermal district heating as `central geothermal-sourced heat pump` based on DEA technology catalogue ("45.1.a Geothermal DH, 1200m, E")
20+
* Fix minor issues in the code
1521

1622
* fix minor issues in the code
1723

outputs/costs_2020.csv

+16-2
Original file line numberDiff line numberDiff line change
@@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_
650650
central coal CHP,efficiency,0.485,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0
651651
central coal CHP,investment,2010.6211,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0
652652
central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0
653+
central excess-heat-sourced heat pump,FOM,0.3003,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0
654+
central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0
655+
central excess-heat-sourced heat pump,efficiency,5.1,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0
656+
central excess-heat-sourced heat pump,investment,704.7435,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0
657+
central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0
653658
central gas CHP,FOM,3.3051,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0
654659
central gas CHP,VOM,4.6562,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0
655660
central gas CHP,c_b,0.96,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0
@@ -669,9 +674,13 @@ central gas boiler,VOM,1.164,EUR/MWh_th,"Danish Energy Agency, technology_data_f
669674
central gas boiler,efficiency,1.03,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0
670675
central gas boiler,investment,63.4933,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0
671676
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0
672-
central geothermal-sourced heat pump,FOM,0.8328,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
677+
central geothermal heat source,FOM,1.4715,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
678+
central geothermal heat source,VOM,6.0281,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
679+
central geothermal heat source,investment,1625.2908,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
680+
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
681+
central geothermal-sourced heat pump,FOM,3.3935,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
673682
central geothermal-sourced heat pump,VOM,6.0281,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
674-
central geothermal-sourced heat pump,investment,2871.7979,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
683+
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
675684
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
676685
central ground-sourced heat pump,FOM,0.3546,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0
677686
central ground-sourced heat pump,VOM,1.0392,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0
@@ -722,6 +731,11 @@ central water pit storage,lifetime,20.0,years,"Danish Energy Agency, technology_
722731
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
723732
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
724733
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
734+
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
735+
central water-sourced heat pump,VOM,1.8942,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0
736+
central water-sourced heat pump,efficiency,3.78,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0
737+
central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0
738+
central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0
725739
clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,
726740
clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0
727741
clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,

outputs/costs_2025.csv

+16-2
Original file line numberDiff line numberDiff line change
@@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_
650650
central coal CHP,efficiency,0.5025,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0
651651
central coal CHP,investment,1989.708,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0
652652
central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0
653+
central excess-heat-sourced heat pump,FOM,0.3003,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0
654+
central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0
655+
central excess-heat-sourced heat pump,efficiency,5.2,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0
656+
central excess-heat-sourced heat pump,investment,704.7435,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0
657+
central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0
653658
central gas CHP,FOM,3.313,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0
654659
central gas CHP,VOM,4.5504,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0
655660
central gas CHP,c_b,0.98,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0
@@ -669,9 +674,13 @@ central gas boiler,VOM,1.1111,EUR/MWh_th,"Danish Energy Agency, technology_data_
669674
central gas boiler,efficiency,1.035,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0
670675
central gas boiler,investment,58.2022,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0
671676
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0
672-
central geothermal-sourced heat pump,FOM,0.8253,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
677+
central geothermal heat source,FOM,1.4691,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
678+
central geothermal heat source,VOM,6.0453,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
679+
central geothermal heat source,investment,1577.4881,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
680+
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
681+
central geothermal-sourced heat pump,FOM,3.2884,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
673682
central geothermal-sourced heat pump,VOM,6.0453,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
674-
central geothermal-sourced heat pump,investment,2808.061,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
683+
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
675684
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
676685
central ground-sourced heat pump,FOM,0.3733,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0
677686
central ground-sourced heat pump,VOM,1.183,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0
@@ -722,6 +731,11 @@ central water pit storage,lifetime,22.5,years,"Danish Energy Agency, technology_
722731
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
723732
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
724733
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
734+
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
735+
central water-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0
736+
central water-sourced heat pump,efficiency,3.8,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0
737+
central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0
738+
central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0
725739
clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,
726740
clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0
727741
clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,

0 commit comments

Comments
 (0)