Drive Groups
drive_group:
host_target: *
data_devices:
ID_MODEL: foo
size: 40G
rotates: 0
wal_devices:
rotates: 1
db_devices: # bluestore can be deployed on 3 devices
osds_per_device: 1 # number of osd daemons per device. To fully utilize nvme devices multiple osds are required.
objectstore: bluestore
encrypted: True
wal_slots: 5
db_slots: 1 # if deploying on 3 devices how many wal volumes per db device
# and other c-v flags like wal_underprovision_ratio, though this is still being discussed
# also some keys are only available when others are present ({wal,db}_devices for bluestore, journal_devices for filestore)This new structure is proposed to serve as a declarative way to specify OSD deployments. On a per host basis OSD deployments are defined by the list of devices and their intended use (data, wal, db or journal) and a list of flags for the deployment tools (ceph-volume in this case).
The Drive Group specification (dg) is intended to be created manually by a user and specifies a group of OSDs that are interrelated (hybrid OSDs that are deployed on solid state and spinners) or share the same deployment options (identical, i.e. same objectstore, same encryption option, ... standalone OSDs)
To avoid explicitly listing devices, we'll rely on a list of filter items. These correspond to a few selected fields of ceph-volume inventory reports. In the simplest case this could be the rotational flag (all solid-state drives are to be wal_devices, all rotating one data devices) or something more involved like model strings, sizes or others.
DeepSea will provide code that translates these drive groups into actual device lists for inspection by the user.
2 Nodes with the same setup:
- 20 HDDs
- Vendor: Intel
- Model: SSD-123-foo
- Size: 4TB
- 2 SSDs
- Vendor: Micron
- Model: MC-55-44-ZX
- Size: 512GB
This is a common setup and can be described quite easily:
drive_group:
target: '*'
data_devices:
model: SSD-123-foo
wal_devices:
model: MC-55-44-XZThis is a simple and valid, but maybe not future-safe configuration. The user may add disks of different vendors in the future, which wouldn't be included with this configuration
We can improve it by reducing the filters on core properties of the drives:
drive_group:
target: '*'
data_devices:
rotates: 1
wal_devices:
rotates: 0Now, we enforce all rotating devices to be declared as 'data devices' and all non-rotating devices will be used as shared_devices (wal, db)
If you know that drives with more than 2TB will always be the slower data devices, you can also filter by size:
drive_group:
target: '*'
data_devices:
size: >2TB
wal_devices:
size: <2TBForcing encryption on your OSDs is as simple as appending 'encrypted: True' to the layout(? need to agree on a terminology, probably layout is bad).
drive_group:
target: '*'
data_devices:
size: >2TB
wal_devices:
size: <2TB
encrypted: TrueThis was a rather simple setup. Following this approach you can also describe more sophisticated setups.
- 20 HDDs
- Vendor: Intel
- Model: SSD-123-foo
- Size: 4TB
- 12 SSDs
- Vendor: Micron
- Model: MC-55-44-ZX
- Size: 512GB
- 2 NVMEs
- Vendor: Samsung
- Model: NVME-QQQQ-987
- Size: 256GB
Here we have two distinct setups;
20 HDDs should share 2 SSDs;
10 SSDs should share 2 NVMes;
This can be described with two layouts.
drive_group:
target: '*'
data_devices:
rotates: 0
wal_devices:
model: MC-55-44-XZ
wal_slots: 5 # How many OSDs per WAL deviceSettings wal_slots: 5 will ensure that only two SSDs will be used ( 10 left )
followed by
drive_group:
target: '*'
data_devices:
model: MC-55-44-XZ
wal_devices:
vendor: samsung
size: 256GB
wal_slots: 5 # How many OSDs per WAL deviceThe examples above assumed that all nodes have the same drives. That's however not always the case. Example:
Node1-5:
- 20 HDDs
- Vendor: Intel
- Model: SSD-123-foo
- Size: 4TB
- 2 SSDs
- Vendor: Micron
- Model: MC-55-44-ZX
- Size: 512GB
Node6-10:
- 5 NVMEs
- Vendor: Intel
- Model: SSD-123-foo
- Size: 4TB
- 20 SSDs
- Vendor: Micron
- Model: MC-55-44-ZX
- Size: 512GB
You can use the 'target' key in the layout to target certain nodes. Salt target notation helps to keep things easy.
drive_group:
target: 'node[1-5]'
data_devices:
rotates: 1
wal_devices:
rotates: 0followed by:
drive_group:
target: 'node[6-10]'
data_devices:
model: MC-55-44-XZ
wal_devices:
model: SSD-123-fooAll previous cases co-colacated the DBs with the WALs. It's however possible to deploy the DB on a dedicated device as well(if it makes sense).
- 20 HDDs
- Vendor: Intel
- Model: SSD-123-foo
- Size: 4TB
- 2 SSDs
- Vendor: Micron
- Model: MC-55-44-ZX
- Size: 512GB
- 2 NVMEs
- Vendor: Samsung
- Model: NVME-QQQQ-987
- Size: 256GB
drive_group:
target: '*'
data_devices:
model: MC-55-44-XZ
wal_devices:
model: SSD-123-foo
db_devices:
model: NVME-QQQQ-987
wal_slots: 10
db_slots: 10Neither Ceph, Deepsea or ceph-volume prevents you from making questionable decisions.
- 23 HDDs
- Vendor: Intel
- Model: SSD-123-foo
- Size: 4TB
- 10 SSDs
- Vendor: Micron
- Model: MC-55-44-ZX
- Size: 512GB
- 1 NVMEs
- Vendor: Samsung
- Model: NVME-QQQQ-987
- Size: 256GB
Here we are trying to define:
20 HDDs backed by 1 NVME
2 HDDs backed by 1 SSD(wal) and 1 NVME(db)
8 SSDs backed by 1 NVME
2 SSDs standalone (encrypted)
1 HDD is spare and should not be deployed
drive_group_hdd_nvme:
target: '*'
data_devices:
rotational: 0
wal_devices:
model: NVME-QQQQ-987
wal_slots: 20drive_group_hdd_ssd_nvme:
target: '*'
data_devices:
rotational: 0
wal_devices:
model: MC-55-44-XZ
db_devices:
model: NVME-QQQQ-987
wal_slots: 2
db_slots: 2drive_group_ssd_nvme:
target: '*'
data_devices:
model: SSD-123-foo
wal_devices:
model: NVME-QQQQ-987
wal_slots: 8drive_group_ssd_standalone_encrypted:
target: '*'
data_devices:
model: SSD-123-foo
encryption: TrueOne HDD will remain as the file is being parsed from top to bottom (it should be.. not implemented!) and the wal_slots(former ratios) are strictly defined.
** Note
it won't be possible to have only 1 standalone SSD. Maybe there should be a 'limit' flag.. on the other hand, there's no reason to leave a disk out..
- Prerequisites
- Manual Installation
- Custom Profiles
- Alternate Installations
- Automated Installation
- Purging
- Reinstallation
- Replacing an OSD
- Inspecting the Configuration
- Understanding Pathnames and Arguments
- Overriding Default Settings
- Overriding Default Steps
- Man Pages
- deepsea.1
- deepsea.7
- deepsea-commands.7
- deepsea-minions.7
- deepsea-monitor.1
- deepsea-policy.cfg.5
- deepsea-stage.1
- deepsea-stage-dry-run.1
- deepsea-stage-run.1
- deepsea-stages.7
- Backporting
- Testing
- Branches & Releases