Notifications
You must be signed in to change notification settings - Fork 35
Expand file tree
/
Copy pathdriver_amiplus.cc
More file actions
245 lines (217 loc) · 13.3 KB
/
Copy pathdriver_amiplus.cc
File metadata and controls
245 lines (217 loc) · 13.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
/*
Copyright (C) 2019-2025 Fredrik Öhrström (gpl-3.0-or-later)
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include"meters_common_implementation.h"
namespace
{
struct Driver : public virtual MeterCommonImplementation
{
Driver(MeterInfo &mi, DriverInfo &di);
};
static bool ok = registerDriver([](DriverInfo&di)
{
di.setName("amiplus");
di.setDefaultFields("name,id,total_energy_consumption_kwh,current_power_consumption_kw,total_energy_production_kwh,current_power_production_kw,voltage_at_phase_1_v,voltage_at_phase_2_v,voltage_at_phase_3_v,total_energy_consumption_tariff_1_kwh,total_energy_consumption_tariff_2_kwh,total_energy_consumption_tariff_3_kwh,total_energy_production_tariff_1_kwh,total_energy_production_tariff_2_kwh,total_energy_production_tariff_3_kwh,timestamp");
di.setMeterType(MeterType::ElectricityMeter);
di.addLinkMode(LinkMode::T1);
di.addDetection(MANUFACTURER_APA, 0x02, 0x02);
di.addDetection(MANUFACTURER_DEV, 0x37, 0x02);
di.addDetection(MANUFACTURER_DEV, 0x02, 0x00);
di.addDetection(MANUFACTURER_DEV, 0x02, 0x01);
// Apator Otus 1/3 seems to use both, depending on a frame.
// Frames with APA are successfully decoded by this driver
// Frames with APT are not - and their content is unknown - perhaps it broadcasts two data formats?
di.addDetection(MANUFACTURER_APA, 0x02, 0x01);
//di.addDetection(MANUFACTURER_APT, 0x02, 0x01);
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return std::shared_ptr<Meter>(new Driver(mi, di)); });
});
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
{
addNumericFieldWithExtractor(
"total_energy_consumption",
"The total energy consumption recorded by this meter.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
);
addNumericFieldWithExtractor(
"current_power_consumption",
"Current power consumption.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Power,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::PowerW)
);
addNumericFieldWithExtractor(
"total_energy_production",
"The total energy production recorded by this meter.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(DifVifKey("0E833C"))
);
addNumericFieldWithExtractor(
"current_power_production",
"Current power production.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Power,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(DifVifKey("0BAB3C"))
);
addNumericFieldWithExtractor(
"voltage_at_phase_1",
"Voltage at phase L1.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Voltage,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Voltage)
.add(VIFCombinable::AtPhase1)
);
addNumericFieldWithExtractor(
"voltage_at_phase_2",
"Voltage at phase L2.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Voltage,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Voltage)
.add(VIFCombinable::AtPhase2)
);
addNumericFieldWithExtractor(
"voltage_at_phase_3",
"Voltage at phase L3.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Voltage,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Voltage)
.add(VIFCombinable::AtPhase3)
);
addStringFieldWithExtractor(
"device_date_time",
"Device date time.",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::DateTime)
);
addNumericFieldWithExtractor(
"total_energy_consumption_tariff_1",
"The total energy consumption recorded by this meter on tariff 1.",
DEFAULT_PRINT_PROPERTIES, // ,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
.set(TariffNr(1))
);
addNumericFieldWithExtractor(
"total_energy_consumption_tariff_2",
"The total energy consumption recorded by this meter on tariff 2.",
DEFAULT_PRINT_PROPERTIES, // ,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
.set(TariffNr(2))
);
addNumericFieldWithExtractor(
"total_energy_consumption_tariff_3",
"The total energy consumption recorded by this meter on tariff 3.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::AnyEnergyVIF)
.set(TariffNr(3))
);
addNumericFieldWithExtractor(
"total_energy_production_tariff_1",
"The total energy production recorded by this meter on tariff 1.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(DifVifKey("8E10833C"))
);
addNumericFieldWithExtractor(
"total_energy_production_tariff_2",
"The total energy production recorded by this meter on tariff 2.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(DifVifKey("8E20833C"))
);
addNumericFieldWithExtractor(
"total_energy_production_tariff_3",
"The total energy production recorded by this meter on tariff 3.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Energy,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(DifVifKey("8E30833C"))
);
addNumericFieldWithExtractor(
"max_power_consumption",
"The maximum demand indicator (maximum 15-min average power consumption recorded this month).",
DEFAULT_PRINT_PROPERTIES,
Quantity::Power,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Maximum)
.set(VIFRange::AnyPowerVIF)
);
}
}
// Test: MyElectricity1 amiplus 10101010 NOKEY
// telegram=|4E4401061010101002027A00004005_2F2F0E035040691500000B2B300300066D00790C7423400C78371204860BABC8FC100000000E833C8074000000000BAB3C0000000AFDC9FC0136022F2F2F2F2F|
// {"_":"telegram","media":"electricity","meter":"amiplus","name":"MyElectricity1","id":"10101010","total_energy_consumption_kwh":15694.05,"current_power_consumption_kw":0.33,"total_energy_production_kwh":7.48,"current_power_production_kw":0,"voltage_at_phase_1_v":236,"device_date_time":"2019-03-20 12:57:00","timestamp":"1111-11-11T11:11:11Z"}
// |MyElectricity1;10101010;15694.05;0.33;7.48;0;236;null;null;null;null;null;null;null;null;1111-11-11 11:11.11
// Test: MyElectricity2 amiplus 00254358 NOKEY
// Comment: amiplus/apator electricity meter with three phase voltages
// telegram=|5E44B6105843250000027A2A005005_2F2F0C7835221400066D404708AC2A400E032022650900000E833C0000000000001B2B9647000B2B5510000BAB3C0000000AFDC9FC0135020AFDC9FC0245020AFDC9FC0339020BABC8FC100000002F2F|
// {"_":"telegram","media":"electricity","meter":"amiplus","name":"MyElectricity2","id":"00254358","total_energy_consumption_kwh":9652.22,"current_power_consumption_kw":1.055,"total_energy_production_kwh":0,"current_power_production_kw":0,"voltage_at_phase_1_v":235,"voltage_at_phase_2_v":245,"voltage_at_phase_3_v":239,"max_power_consumption_kw":4.796,"device_date_time":"2021-10-12 08:07:00","timestamp":"1111-11-11T11:11:11Z"}
// |MyElectricity2;00254358;9652.22;1.055;0;0;235;245;239;null;null;null;null;null;null;1111-11-11 11:11.11
// Test: MyElectricity3 amiplus 86064864 NOKEY
// Comment: amiplus/apator electricity meter with three phase voltages and 2 tariffs.
// telegram=|804401066448068602027A000070052F2F_066D1E5C11DA21400C78644806868E10036110012500008E20038106531800008E10833C9949000000008E20833C8606000000001B2B5228020B2B3217000BAB3C0000000AFDC9FC0131020AFDC9FC0225020AFDC9FC0331020BABC8FC100000002F2F2F2F2F2F2F2F2F2F2F2F2FDE47|
// {"_":"telegram","media":"electricity","meter":"amiplus","name":"MyElectricity3","id":"86064864","current_power_consumption_kw":1.732,"current_power_production_kw":0,"voltage_at_phase_1_v":231,"voltage_at_phase_2_v":225,"voltage_at_phase_3_v":231,"device_date_time":"2022-01-26 17:28:30","total_energy_consumption_tariff_1_kwh":25011.061,"total_energy_consumption_tariff_2_kwh":18530.681,"total_energy_production_tariff_1_kwh":4.999,"total_energy_production_tariff_2_kwh":0.686,"max_power_consumption_kw":22.852,"timestamp":"1111-11-11T11:11:11Z"}
// |MyElectricity3;86064864;null;1.732;null;0;231;225;231;25011.061;18530.681;null;4.999;0.686;null;1111-11-11 11:11.11
// Test: MyElectricity4 amiplus 55090884 NOKEY
// Comment: amiplus/apator electricity meter with single phase voltage - Otus 1
// telegram=|7E4401068408095501027A7C1070052F2F_066DDE5E150D39800C78840809550AFDC9FC0139028E30833C0000000000008E20833C0000000000008E10833C4301000000000BABC8FC100000008E10035336420200008E20030000000000008E30030000000000000B2B9502000BAB3C0000002F2F2F2F2F2F2F2F2F2F2F2F2F|
// {"_":"telegram","media":"electricity","meter":"amiplus","name":"MyElectricity4","id":"55090884","current_power_consumption_kw":0.295,"current_power_production_kw":0,"total_energy_consumption_tariff_1_kwh":2423.653,"total_energy_consumption_tariff_2_kwh":0,"total_energy_consumption_tariff_3_kwh":0,"total_energy_production_tariff_1_kwh":0.143,"total_energy_production_tariff_2_kwh":0,"total_energy_production_tariff_3_kwh":0,"voltage_at_phase_1_v":239,"device_date_time":"2024-09-13 21:30:30","timestamp":"1111-11-11T11:11:11Z"}
// |MyElectricity4;55090884;null;0.295;null;0;239;null;null;2423.653;0;0;0.143;0;0;1111-11-11 11:11.11
// Test: MyElectricity4 amiplus 00320787 NOKEY
// telegram=|3e44b6108707320001027a380030052f2f0C7830253390066D6872141239400E031891690000000E833C9265010000000B2B2602000BAB3C0000002F2F2F2F|
// {"_":"telegram","current_power_consumption_kw": 0.226,"current_power_production_kw": 0,"device_date_time": "2024-09-18 20:50:40","id": "00320787","media": "electricity","meter": "amiplus","name": "MyElectricity4","timestamp": "1111-11-11T11:11:11Z","total_energy_consumption_kwh": 699.118,"total_energy_production_kwh": 16.592}
// |MyElectricity4;00320787;699.118;0.226;16.592;0;null;null;null;null;null;null;null;null;null;1111-11-11 11:11.11
// Test: MyElectricity5 amiplus 56914504 NOKEY
// telegram=|9e4401060445915601027a3d0390052f2f066dc076091935800c78044591560e032088300000008e10032088300000008e20030000000000008e30030000000000008e8010030000000000000e833c2702000000008e10833c2702000000008e20833c0000000000008e30833c0000000000008e8010833c0000000000000afdc8fc0136240afdc8fc0262240afdc8fc0389222f2f2f2f2f2f2f2f2f2f2f2f|
// {"_":"telegram","media":"electricity","meter":"amiplus","name":"MyElectricity5","id":"56914504","total_energy_consumption_kwh":308.82,"total_energy_consumption_tariff_1_kwh":308.82,"total_energy_consumption_tariff_2_kwh":0,"total_energy_consumption_tariff_3_kwh":0,"total_energy_production_kwh":0.227,"total_energy_production_tariff_1_kwh":0.227,"total_energy_production_tariff_2_kwh":0,"total_energy_production_tariff_3_kwh":0,"voltage_at_phase_1_v":243.6,"voltage_at_phase_2_v":246.2,"voltage_at_phase_3_v":228.9,"device_date_time":"2024-05-25 09:54:00","timestamp":"1111-11-11T11:11:11Z"}
// |MyElectricity5;56914504;308.82;null;0.227;null;243.6;246.2;228.9;308.82;0;0;0.227;0;0;1111-11-11 11:11.11