Notifications
You must be signed in to change notification settings - Fork 35
Expand file tree
/
Copy pathdriver_lse_07_17.cc
More file actions
215 lines (190 loc) · 9.21 KB
/
Copy pathdriver_lse_07_17.cc
File metadata and controls
215 lines (190 loc) · 9.21 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
/*
Copyright (C) 2021-2024 Fredrik Öhrström (gpl-3.0-or-later)
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include"meters_common_implementation.h"
namespace
{
struct Driver : public virtual MeterCommonImplementation
{
Driver(MeterInfo &mi, DriverInfo &di);
};
static bool ok = registerDriver([](DriverInfo&di)
{
di.setName("lse_07_17");
di.setDefaultFields("name,id,total_m3,due_date_m3,due_date,error_code,error_date,device_date_time,timestamp");
di.setMeterType(MeterType::WaterMeter);
di.addLinkMode(LinkMode::S1);
di.addDetection(MANUFACTURER_LSE, 0x06, 0x18);
di.addDetection(MANUFACTURER_LSE, 0x07, 0x18);
di.addDetection(MANUFACTURER_LSE, 0x07, 0x16);
di.addDetection(MANUFACTURER_LSE, 0x07, 0x17);
di.addDetection(MANUFACTURER_LSE, 0x07, 0xd8);
di.setConstructor([](MeterInfo& mi, DriverInfo& di){ return std::shared_ptr<Meter>(new Driver(mi, di)); });
});
Driver::Driver(MeterInfo &mi, DriverInfo &di) : MeterCommonImplementation(mi, di)
{
addNumericFieldWithExtractor(
"total",
"The total water consumption recorded by this meter.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Volume,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Volume)
);
addNumericFieldWithExtractor(
"due_date",
"The water consumption at the due date.",
DEFAULT_PRINT_PROPERTIES,
Quantity::Volume,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Volume)
.set(StorageNr(1))
);
addStringFieldWithExtractor(
"due_date",
"The due date configured on the meter.",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Date)
.set(StorageNr(1))
);
addNumericFieldWithExtractor(
"what_date",
"The water consumption at the what date?",
DEFAULT_PRINT_PROPERTIES,
Quantity::Volume,
VifScaling::Auto, DifSignedness::Signed,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Volume)
.set(StorageNr(8))
);
addStringFieldWithExtractor(
"what_date",
"The what date?",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::Date)
.set(StorageNr(8))
);
addStringFieldWithExtractorAndLookup(
"error_code",
"Error code of the Meter, 0 means no error.",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(DifVifKey("02BB56")
),
{
{
{
"ERROR_FLAGS",
Translate::MapType::BitToString,
AlwaysTrigger, MaskBits(0xffff),
"OK",
{
// { 0x01, "?" },
}
},
},
});
addStringFieldWithExtractor(
"error_date",
"The date the error occurred at. If no error, reads 2127-15-31 (FFFF).",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(MeasurementType::AtError)
.set(VIFRange::Date)
);
addStringFieldWithExtractor(
"device_date_time",
"Date when measurement was recorded.",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::DateTime)
);
addStringFieldWithExtractor(
"meter_version",
"Meter model/version.",
DEFAULT_PRINT_PROPERTIES,
FieldMatcher::build()
.set(MeasurementType::Instantaneous)
.set(VIFRange::ModelVersion)
);
}
}
/*
The following telegram corresponds to the Qundis QWater5.5 cold water meters I have here.
From the device display it states that it is set to S-mode operation, sending a telegram
every 4 h.
Another option of this device is the C mode operation, sending telegrams every
7.5 s.
Even though my meters are definitely Qundis QWater5.5, the meters do not identify with
manufacturer code QDS but with LSE.
(lse_07_17) 0f: 0C dif (8 digit BCD Instantaneous value)
(lse_07_17) 10: 13 vif (Volume l)
(lse_07_17) 11: * 04400100 total consumption (14.004000 m3)
(lse_07_17) 15: 4C dif (8 digit BCD Instantaneous value storagenr=1)
(lse_07_17) 16: 13 vif (Volume l)
(lse_07_17) 17: * 40620000 due date consumption (6.240000 m3)
(lse_07_17) 1b: 42 dif (16 Bit Integer/Binary Instantaneous value storagenr=1)
(lse_07_17) 1c: 6C vif (Date type G)
(lse_07_17) 1d: * 9F2C due date (2020-12-31)
(lse_07_17) 1f: 02 dif (16 Bit Integer/Binary Instantaneous value)
(lse_07_17) 20: BB vif (Volume flow l/h)
(lse_07_17) 21: 56 vife (duration of limit exceed last lower is 2)
(lse_07_17) 22: * 0000 error code (0)
(lse_07_17) 24: 32 dif (16 Bit Integer/Binary Value during error state)
(lse_07_17) 25: 6C vif (Date type G)
(lse_07_17) 26: * FFFF error date (2127-15-31)
(lse_07_17) 28: 04 dif (32 Bit Integer/Binary Instantaneous value)
(lse_07_17) 29: 6D vif (Date and time type)
(lse_07_17) 2a: * 180DA924 device datetime (2021-04-09 13:24)
if (findKey(MeasurementType::Instantaneous, VIFRange::DateTime, 0, 0, &key, &t->dv_entries)) {
struct tm datetime;
extractDVdate(&t->dv_entries, key, &offset, &datetime);
device_date_time_ = strdatetime(&datetime);
t->addMoreExplanation(offset, " device datetime (%s)", device_date_time_.c_str());
}
// How do the following error codes on the display map to the code in the telegram?
// According to the datasheet, these errors can appear on the display:
// LEAC Leak in the system (no associated error code)
// 0 Negative direction of flow.
// 2 Operating hours expired.
// 3 Hardware error.
// 4 Permanently stored error.
// b Communication via OPTO too often per month.
// c Communication via M-Bus too often per month.
// d Flow too high.
// f Device was without voltage supply briefly. All parameter settings are lost.
*/
// Test: Water lse_07_17 13963399 NOKEY
// telegram=|244465329933961318067AE1000000_8C04130070000082046CBE2B01FD0C11046D010CA22C|
// {"_":"telegram","media":"warm water","meter":"lse_07_17","name":"Water","id":"13963399","what_date_m3":7,"what_date":"2021-11-30","device_date_time":"2021-12-02 12:01","meter_version":"11","timestamp":"1111-11-11T11:11:11Z"}
// |Water;13963399;null;null;null;null;null;2021-12-02 12:01;1111-11-11 11:11.11
// telegram=|2A4465329933961318067AD8800000_8C04130070000082046CBE2B01FD0C11046D1800A12C02FDAC7E9B2E|
// {"_":"telegram","media":"warm water","meter":"lse_07_17","name":"Water","id":"13963399","what_date_m3":7,"what_date":"2021-11-30","device_date_time":"2021-12-01 00:24","meter_version":"11","timestamp":"1111-11-11T11:11:11Z"}
// |Water;13963399;null;null;null;null;null;2021-12-01 00:24;1111-11-11 11:11.11
// telegram=|2D4465329933961318067ADA000000_0C13567100004C1300000000426CFFFF02BB560000326CFFFF046D2307A12C|
// {"_":"telegram","media":"warm water","meter":"lse_07_17","name":"Water","id":"13963399","total_m3":7.156,"due_date_m3":0,"due_date":"2127-15-31","what_date_m3":7,"what_date":"2021-11-30","error_code":"OK","error_date":"2127-15-31","device_date_time":"2021-12-01 07:35","meter_version":"11","timestamp":"1111-11-11T11:11:11Z"}
// |Water;13963399;7.156;0;2127-15-31;OK;2127-15-31;2021-12-01 07:35;1111-11-11 11:11.11
// Test: Water2 lse_07_17 09993623 NOKEY
// telegram=|2d44653223369909d8077a80000000046d130aed2B0c13233332004c1351762700426cdf2c326cffff02BB560000|
// {"_":"telegram","device_date_time": "2023-11-13 10:19","due_date": "2022-12-31","due_date_m3": 277.651,"error_code": "OK","error_date": "2127-15-31","id": "09993623","media": "water","meter": "lse_07_17","name": "Water2","timestamp": "1111-11-11T11:11:11Z","total_m3": 323.323}
// |Water2;09993623;323.323;277.651;2022-12-31;OK;2127-15-31;2023-11-13 10:19;1111-11-11 11:11.11