Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathbandwidth_monitor.py
175 lines (145 loc) · 6.74 KB
/
bandwidth_monitor.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
import subprocess
import time
import signal
import os
import re
import sys
LC_instr = {
"microbench": "perf stat -I 1000 -o temp.log sh /home/wjy/SComet/benchmarks/microbenchmark/script/microbench.sh",
"memcached": "perf stat -I 1000 -o temp.log sh /home/wjy/SComet/benchmarks/memcached/script/memcached.sh 4",
"nginx": "perf stat -I 1000 -o temp.log sh /home/wjy/SComet/benchmarks/nginx/script/nginx.sh 4",
}
def run_and_monitor_bw(program, run_time):
try:
# subprocess.Popen('pqos -R -e "mba:1=80"', shell=True).wait()
# subprocess.Popen('pqos -R -e "mba:2=20"', shell=True).wait()
# subprocess.Popen('pqos -a "llc:1=0"', shell=True).wait()
# subprocess.Popen('pqos -a "llc:2=1"', shell=True).wait()
pqos_proc = subprocess.Popen("pqos -r", shell=True, preexec_fn=os.setsid)
os.killpg(os.getpgid(pqos_proc.pid), signal.SIGTERM)
pqos_proc.wait()
program_proc = subprocess.Popen("taskset -c 1 " + program, shell=True, preexec_fn=os.setsid)
pqosout = open("pqos.all", "w")
pqos_proc = subprocess.Popen("taskset -c 2 pqos -i 1 -m all:1", shell=True, stdout=pqosout, preexec_fn=os.setsid)
time.sleep(run_time)
os.killpg(os.getpgid(program_proc.pid), signal.SIGTERM)
os.killpg(os.getpgid(pqos_proc.pid), signal.SIGTERM)
total_mbl = 0
count = 0
with open("pqos.all", 'r') as f:
file = f.readlines()
for i in range(len(file)):
if 'MBL[MB/s]' in file[i]:
parts = file[i+1].split()
if len(parts) >= 6:
try:
mbl_value = float(parts[4])
total_mbl += mbl_value
count += 1
except ValueError:
pass
if count == 0:
print("No MBL data found.")
else:
avg_mbl = total_mbl / count
print(f"Average MBL: {avg_mbl:.2f} MB/s")
subprocess.Popen("rm -rf pqos.all", shell=True).wait()
subprocess.Popen('pqos -R', shell=True).wait()
return avg_mbl
except KeyboardInterrupt:
print("Monitoring interrupted.")
os.kill(program_proc.pid, signal.SIGTERM)
def run_and_monitor_interference(program, run_time):
try:
# subprocess.Popen('pqos -R -e "mba:1=80"', shell=True).wait()
subprocess.Popen('pqos -R -e "mba:2=20"', shell=True).wait()
# subprocess.Popen('pqos -a "llc:1=0"', shell=True).wait()
subprocess.Popen('pqos -a "llc:2=1"', shell=True).wait()
pqos_proc = subprocess.Popen("pqos -r", shell=True, preexec_fn=os.setsid)
os.killpg(os.getpgid(pqos_proc.pid), signal.SIGTERM)
pqos_proc.wait()
LC_proc = subprocess.Popen("taskset -c 0 sh /home/wjy/SComet/benchmarks/microbenchmark/script/microbench.sh",
shell=True, preexec_fn=os.setsid)
pqosout = open("pqos.all", "w")
pqos_proc = subprocess.Popen("taskset -c 2 pqos -i 1 -m all:0", shell=True, stdout=pqosout,
preexec_fn=os.setsid)
time.sleep(run_time)
os.killpg(os.getpgid(LC_proc.pid), signal.SIGTERM)
os.killpg(os.getpgid(pqos_proc.pid), signal.SIGTERM)
total_IPC = 0
count = 0
with open("pqos.all", 'r') as f:
file = f.readlines()
for i in range(len(file)):
if 'IPC' in file[i]:
parts = file[i + 1].split()
if len(parts) >= 6:
try:
IPC_value = float(parts[1])
total_IPC += IPC_value
count += 1
except ValueError:
pass
if count == 0:
print("No IPC data found.")
else:
solo_IPC = total_IPC / count
print(f"Solo IPC: {solo_IPC:.2f}")
pqos_proc = subprocess.Popen("pqos -r", shell=True, preexec_fn=os.setsid)
os.killpg(os.getpgid(pqos_proc.pid), signal.SIGTERM)
pqos_proc.wait()
LC_proc = subprocess.Popen("taskset -c 0 sh /home/wjy/SComet/benchmarks/microbenchmark/script/microbench.sh", shell=True, preexec_fn=os.setsid)
program_proc = subprocess.Popen("taskset -c 1 " + program, shell=True, preexec_fn=os.setsid)
pqosout = open("pqos.all", "w")
pqos_proc = subprocess.Popen("taskset -c 2 pqos -i 1 -m all:0", shell=True, stdout=pqosout, preexec_fn=os.setsid)
time.sleep(run_time)
os.killpg(os.getpgid(LC_proc.pid), signal.SIGTERM)
os.killpg(os.getpgid(program_proc.pid), signal.SIGTERM)
os.killpg(os.getpgid(pqos_proc.pid), signal.SIGTERM)
total_IPC = 0
count = 0
with open("pqos.all", 'r') as f:
file = f.readlines()
for i in range(len(file)):
if 'IPC' in file[i]:
parts = file[i+1].split()
if len(parts) >= 6:
try:
IPC_value = float(parts[1])
total_IPC += IPC_value
count += 1
except ValueError:
pass
if count == 0:
print("No IPC data found.")
else:
corun_IPC = total_IPC / count
print(f"Corun IPC: {corun_IPC:.2f}")
print(corun_IPC / solo_IPC)
subprocess.Popen("rm -rf pqos.all", shell=True).wait()
subprocess.Popen('pqos -R', shell=True).wait()
return corun_IPC / solo_IPC
except KeyboardInterrupt:
print("Monitoring interrupted.")
os.kill(program_proc.pid, signal.SIGTERM)
if __name__ == "__main__":
if len(sys.argv) != 3:
print("Usage: python pqos_bandwidth_monitor.py '<program>' <run_time>")
sys.exit(1)
benchmark_set = sys.argv[1]
run_duration = int(sys.argv[2])
benchmark_list = []
for root, dirs, files in os.walk('./benchmarks/' + benchmark_set + '/script'):
for file in files:
if file.split('.')[-1] == 'sh':
benchmark_list.append('.'.join(file.split('.')[0:-1]))
benchmark_list.sort()
print('benchmark list:')
print(benchmark_list)
result = {}
for benchmark in benchmark_list:
instr = f"bash ./benchmarks/{benchmark_set}/script/{benchmark}.sh"
bw = run_and_monitor_bw(instr, run_duration)
ipc = run_and_monitor_interference(instr, run_duration)
result[benchmark] = (bw, ipc)
print(result)