SolarMax — MaxTalk over RS485

Experimental, and unusually so: no SolarMax has ever answered this driver. The protocol was implemented from two independent published sources that agree on the framing. Several scaling factors rest on only one of them, and one is left unmapped because the two disagree. Read What is not published, and why before trusting a number.

Sputnik Engineering, which made these inverters, went bankrupt in 2014 and its monitoring portal went with it. The hardware kept working. This driver exists so those units can still report something without a vendor.

Wiring

Ordinary RS485: A, B and ground, chained rather than starred, 120 Ω at each end of the run. See rs485-bus.md — none of that is specific to this family.

On the inverter's own connector the published pinout is pin 7 = A (485+) and pin 8 = B (485−). Some models and the separate accessories need 12–15 V DC supplied on the same connector to power their communication side; the inverter's manual is the authority on which.

Line settings and addressing

Baud 19200
Format 8 data bits, no parity, 1 stop bit
Address set in the inverter's own display menu, 0–255

There is no registration handshake. Nothing is assigned over the wire: the inverter answers at whatever address its operator configured, and the driver simply asks. Two consequences worth having:

  • Discovery is genuinely read-only here. A probe sends a question and changes no state, unlike the AA55 family where a device must be assigned an address before it answers at all.
  • Several inverters on one bus is ordinary, not an exception — give each one its own address in its menu, and set the matching address option per device here. A duplicate in the menu is a duplicate on the wire, and this protocol has no way to detect that for you.

The protocol, briefly

ASCII, brace-delimited, request and response:

request  {FB;05;36|64:CAC;KHR;KDY;KMT;KYR;KT0;KLD;KLM;KLY|0D34}
reply    {05;FB;59|64:CAC=1F3E;KHR=26D6;KDY=8E;KMT=8D;KYR=221;...|154C}

{sender;recipient;length|64:payload|checksum}. The querying computer is FB. Length counts the whole frame including both braces. The checksum is every character after the opening brace up to and including the | before it, summed and reduced to 16 bits.

Two properties that make this family pleasant to read:

  • A frame ends at }, so nothing depends on inter-character timing or on trusting the length field before the frame is complete.
  • One request carries many codes and gets many answers, so a full poll is a single transaction rather than one per channel — which matters on a shared half-duplex line.

The framing lives in src/protocols/maxtalk/ and names no brand; the mapping below is in src/drivers/solarmax/.

What is published

Code Channel Divisor Sources
PAC ac.power.total 2 both
PDC dc.power.total 2 one
UL1 UL2 UL3 ac.phase_lN.voltage 10 UL1 both, the others one
IL1 IL2 IL3 ac.phase_lN.current 100 IL1 both, the others one
TNF ac.frequency 100 one
TKK inverter.temperature 1 one
UD01UD03 dc.mppt_1..3.voltage 10 one
ID01ID03 dc.mppt_1..3.current 100 one
KDY energy.today 10 both
KT0 energy.total 1 both
KHR inverter.operating_hours 1 one
SYS status code one
SAL error code one

The phase and string counts are not declared in advance: they follow what the device actually answers. Asking a single-phase unit for UL2 simply gets no UL2 back, and the channel then reads as absent rather than zero.

The status code is reported as a number with no words attached. Neither source enumerates the status table, and inventing labels for it would be a guess wearing a label.

What is not published, and why

UDC — DC voltage — is deliberately unmapped. The two sources conflict: one scales it like AC voltage (divide by ten), the other leaves it raw. Picking a winner is exactly what this project's two-source rule exists to prevent, and a DC voltage wrong by a factor of ten is a number an operator would believe. IDC is left out with it, because alone it would be a current with no voltage beside it — and it may simply be another name for ID01 on a single-string unit.

On a device that reports per-string values (UD01/ID01) nothing is lost. On one that reports only the totals, DC voltage and current will be missing entirely. That is the honest outcome rather than a plausible wrong one, and it is the first thing a hardware session should settle.

Four energy codes are not asked for at all: KMT, KLM, KYR, KLY — this month, last month, this year, last year. There is no canonical id for them, and a code with nowhere to go is payload spent for nothing on a shared bus. Giving them a home is a vocabulary decision rather than a driver one; until it is taken, the driver does not query them.

Nothing is writable. Neither source documents a write or control command for this protocol, so the driver declares no write capability at all and the dispatcher refuses any command before it reaches the device.

What a hardware session should check, in order

  1. UDC's divisor, against the inverter's own display. It is the only conflict.
  2. Whether UDC and UD01 are the same measurement.
  3. The single-sourced divisorsPDC, UL2, UL3, IL2, IL3, TNF, TKK, KHR.
  4. The |64: literal: fixed across the range, or a selector that varies by series.
  5. The SYS and SAL code tables, which neither source enumerates.

If you have one of these inverters, that list is the whole contribution — five answers, and this driver stops being guesswork.

Which models

The sources name the S-series explicitly and refer to C, MT and TS elsewhere. Whether the code vocabulary is constant across the range is unknown. A model that answers a query with a correct checksum is speaking this protocol; whether its numbers mean what the table above says is the open question.

The reasoning behind the design, and which claim came from which source, is recorded in solarmax-maxtalk-plan-2026-08-09.md.