Open
Description
I'm using the following command line on Windows 10:
"C:\Program Files\Cura 2.4\CuraEngine.exe" slice -j "c:\Program Files\Cura 2.4\resources\definitions\prusa_i3_mk2.def.json" -l Marvin.stl -o Marvin.gcode
Output gcode has duplicate M104 and it doesn't set the temperatures properly on my Prusa Mk2.
;FLAVOR:RepRap
;TIME:6666
;Generated with Cura_SteamEngine 2.3.1
M190 S55
M104 S210
M109 S210
G21 ; set units to millimeters
G90 ; use absolute positioning
M82 ; absolute extrusion mode
G28 W ; home all without mesh bed level
G80 ; mesh bed leveling
M104 S{material_print_temperature} ; set extruder temp
M140 S{material_bed_temperature} ; set bed temp
M190 S{material_bed_temperature} ; wait for bed temp
M109 S{material_print_temperature} ; wait for extruder temp
G92 E0.0 ; reset extruder distance position
G1 Y-3.0 F1000.0 ; go outside print area
G1 X60.0 E9.0 F1000.0 ; intro line
G1 X100.0 E21.5 F1000.0 ; intro line
G92 E0.0 ; reset extruder distance position
;LAYER_COUNT:278
whereas GUI generated gcode starts:
;FLAVOR:RepRap
;TIME:5494
;Generated with Cura_SteamEngine 2.3.1
G21 ; set units to millimeters
G90 ; use absolute positioning
M82 ; absolute extrusion mode
G28 W ; home all without mesh bed level
G80 ; mesh bed leveling
M104 S215 ; set extruder temp
M140 S55 ; set bed temp
M190 S55 ; wait for bed temp
M109 S215 ; wait for extruder temp
G92 E0.0 ; reset extruder distance position
G1 Y-3.0 F1000.0 ; go outside print area
G1 X60.0 E9.0 F1000.0 ; intro line
G1 X100.0 E21.5 F1000.0 ; intro line
G92 E0.0 ; reset extruder distance position
;LAYER_COUNT:462