SMP notifications used to deliver SMP responses over BLE transport are corrupted on the apollo3_evb.
Below is a sample log from nRF Connect app attempting an image list command (as part of the DFU process). You can see the response being fragmented over two notifications, with the second notification corrupted. As a result, the concatenated CBOR is not decodable. The response does not need to be corrupted - the issue exists even for single-packet responses.
This is reproducible with stock bleprph on apollo3_evb.
This is NOT reproducible with the same app on nordic_pca10056.
Error can be observed with the nRF Connect app or the nRF Device Manager app for Android/iOS (CBOR Error).
V 17:20:50.573 Connecting to 66:77:88:23:BB:EF...
D 17:20:50.573 gatt = device.connectGatt(autoConnect = false, TRANSPORT_LE, preferred PHY = LE 1M)
D 17:20:56.145 [Callback] Connection state changed with status: 133 and new state: DISCONNECTED (0)
E 17:20:56.150 Error 133 (0x85): GATT ERROR
I 17:20:56.150 Disconnected
D 17:20:58.707 gatt.close()
D 17:20:58.709 wait(200)
V 17:20:58.910 Connecting to 66:77:88:23:BB:EF...
D 17:20:58.910 gatt = device.connectGatt(autoConnect = false, TRANSPORT_LE, preferred PHY = LE 1M)
D 17:21:02.715 [Callback] Connection state changed with status: 0 and new state: CONNECTED (2)
I 17:21:02.715 Connected to 66:77:88:23:BB:EF
V 17:21:02.715 Requesting new MTU...
D 17:21:02.715 gatt.requestMtu(517)
I 17:21:03.159 Connection parameters updated (interval: 7.5ms, latency: 0, timeout: 5000ms)
I 17:21:03.391 MTU changed to: 256
V 17:21:03.398 Discovering services...
D 17:21:03.398 gatt.discoverServices()
D 17:21:03.404 [Callback] Services discovered with status: 0
I 17:21:03.404 Services discovered
V 17:21:03.406 Generic Access (0x1800)
- Device Name [R] (0x2A00)
- Appearance [R] (0x2A01)
Device Information (0x180A)
- Model Number String [R] (0x2A24)
- Serial Number String [R] (0x2A25)
- Firmware Revision String [R] (0x2A26)
- Manufacturer Name String [R] (0x2A29)
SMP Service (8d53dc1d-1db7-4cd3-868b-8a527460aa84)
- SMP Characteristic [N WNR] (da2e7828-fbce-4e01-ae9e-261174997c48)
Client Characteristic Configuration (0x2902)
I 17:21:03.474 Connection parameters updated (interval: 45.0ms, latency: 0, timeout: 5000ms)
V 17:21:08.902 [McuMgr] Connecting...
D 17:21:08.905 [McuMgr] gatt = device.connectGatt(autoConnect = false, TRANSPORT_LE, LE 1M)
D 17:21:08.953 [McuMgr] [Callback] Connection state changed with status: 0 and new state: 2 (CONNECTED)
I 17:21:08.958 [McuMgr] Connected to 66:77:88:23:BB:EF
D 17:21:08.962 [McuMgr] wait(300)
I 17:21:08.966 [McuMgr] MTU changed to: 256
V 17:21:09.266 [McuMgr] Discovering services...
D 17:21:09.271 [McuMgr] gatt.discoverServices()
I 17:21:09.276 [McuMgr] Services discovered
V 17:21:09.286 [McuMgr] Primary service found
V 17:21:09.290 [McuMgr] Requesting new MTU...
D 17:21:09.292 [McuMgr] gatt.requestMtu(498)
I 17:21:09.370 [McuMgr] MTU changed to: 256
D 17:21:09.374 [McuMgr] gatt.setCharacteristicNotification(da2e7828-fbce-4e01-ae9e-261174997c48, true)
V 17:21:09.378 [McuMgr] Enabling notifications for da2e7828-fbce-4e01-ae9e-261174997c48
D 17:21:09.381 [McuMgr] gatt.writeDescriptor(00002902-0000-1000-8000-00805f9b34fb, value=0x01-00)
I 17:21:09.459 [McuMgr] Data written to descr. 00002902-0000-1000-8000-00805f9b34fb, value: (0x) 01-00
I 17:21:09.464 [McuMgr] Notifications enabled
A 17:21:09.470 [McuMgr] Sending (10 bytes) Header (Op: 0, Flags: 0, Len: 2, Group: 1, Seq: 0, Command: 0) CBOR {}
V 17:21:09.480 [McuMgr] Writing characteristic da2e7828-fbce-4e01-ae9e-261174997c48 (WRITE COMMAND)
D 17:21:09.484 [McuMgr] gatt.writeCharacteristic(da2e7828-fbce-4e01-ae9e-261174997c48)
I 17:21:09.489 [McuMgr] Data written to da2e7828-fbce-4e01-ae9e-261174997c48, value: (0x) 00-00-00-02-00-01-00-00-BF-FF
I 17:21:09.648 [McuMgr] Notification received from da2e7828-fbce-4e01-ae9e-261174997c48, value: (0x) 01-00-00-FC-00-01-00-00-BF-66-69-6D-61-67-65-73-9F-BF-64-73-6C-6F-74-00-67-76-65-72-73-69-6F-6E-69-31-2E-30-2E-30-2E-34-37-39-64-68-61-73-68-58-20-B2-27-75-77-F3-C1-C3-BF-E5-AA-26-64-7C-DF-77-AD-26-27-C8-EC-58-E3-C5-DC-8D-3B-97-B6-51-9E-73-BC-68-62-6F-6F-74-61-62-6C-65-F5-67-70-65-6E-64-69-6E-67-F4-69-63-6F-6E-66-69-72-6D-65-64-F5-66-61-63-74-69-76-65-F5-69-70-65-72-6D-61-6E-65-6E-74-F4-FF-BF-64-73-6C-6F-74-01-67-76-65-72-73-69-6F-6E-69-31-2E-30-2E-30-2E-34-37-39-64-68-61-73-68-58-20-9F-46-47-02-D7-E9-BA-FD-57-69-BF-73-42-88-86-85-A0-1B-66-C1-B7-84-48-0A-E3-E8-F8-B5-12-95-80-F7-68-62-6F-6F-74-61-62-6C-65-F5-67-70-65-6E-64-69-6E-67-F4-69-63-6F-6E-66-69-72-6D-65-64-F4-66-61-63-74-69-76-65-F4-69-70-65-72-6D-61-6E-65-6E-74-F4-FF-FF-6B-73-70-6C-69-74-53
I 17:21:10.226 [McuMgr] Notification received from da2e7828-fbce-4e01-ae9e-261174997c48, value: (0x) 74-53-00-FC-00-01-00
V 17:21:10.246 [McuMgr] Disconnecting...
D 17:21:10.253 [McuMgr] gatt.disconnect()
D 17:21:10.289 [McuMgr] [Callback] Connection state changed with status: 0 and new state: 0 (DISCONNECTED)
I 17:21:10.294 [McuMgr] Disconnected
D 17:21:10.299 [McuMgr] gatt.close()
The expected second notification (at t=17:21:10.226) should be:
74-61-74-75-73-00-FF