Release Notes

Buy Me A Coffee


v0.9.1b4

Issues: #305

  • Fix: Inverter Status shows wrong text on hybrid inverters (Issue #305): The Inverter Status sensor was using a single status code table shared across all inverter families. Hybrid inverters (SPH, SPM, MOD, WIT, MIN TL-XH, SPA, SPE) use the V1.39 / VPP Protocol V2.01 status map where the codes have completely different meanings to the grid-tied map — most critically, code 5 was shown as "Standby" when the correct label is "PV On-Grid", and code 1 was shown as "Normal" when it means "Self-Test" on hybrid models. SPF off-grid inverters have their own distinct status set (0=Standby, 2=Discharge, 5=PV Charge, etc.) which was previously mixed into the same dict and would now also collide.

    Fixed by introducing three separate status code tables (STATUS_CODES for grid-tied, HYBRID_STATUS_CODES for hybrid, SPF_STATUS_CODES for off-grid) and selecting the correct table at runtime based on the active profile. Hybrid status codes are now:

    Code Label
    0 Waiting
    1 Self-Test
    2 Reserved
    3 Fault
    4 Updating
    5 PV On-Grid
    6 Bat On-Grid
    7 PV+Bat Off-Grid
    8 Bat Off-Grid
    9 Bypass
  • Docs: corrected legacy storage register 1000 (uwSysWorkMode) status description: The protocol-v139 reference table previously showed 0x05-0x08=Normal for register 1000. Updated to list each code individually, matching the VPP Protocol V2.01 register 31000 definition which was already correct in the docs.


v0.9.1b3

Issues: #304

  • Fix: MIC 2500-5500MTL-S entities all unavailable (Issue #304): The inverter rejects Modbus reads of more than one register at a time (responds with ExceptionResponse FC=132, exception_code=1 — Illegal Function for any block read). Fixed by adding per-profile max_block_size support to the coordinator. When a profile sets max_block_size: 1, the coordinator switches to sparse read mode: it reads only the specific register addresses defined in the profile, grouped into consecutive runs of at most max_block_size registers, skipping all gaps. This also eliminates unnecessary register reads for registers not defined in the profile. All other profiles continue to use the original dense read mode (contiguous 125-register block reads) unchanged.

v0.9.1b2

Issues: #299, #303, #304

  • New profile: Growatt 3000-15000TL3-S (Issue #299): Added support for the TL3-S three-phase grid-tied string inverter (3–15 kW, legacy protocol). Register layout confirmed from a full device scan: PV inputs at regs 3–8 (PV1 voltage/current/power and PV2 voltage/current), total AC power at reg 12, per-phase output (R/S/T) at regs 16–25, temperature at reg 32, and energy at standalone regs 53/55 (×0.1 kWh). Auto-detected via DTC 2049 at holding register 43. No VPP support — holding register 30000 returns Illegal Function. Note: regs 9–10 contain firmware version bytes (not PV2 power), so PV2 power stays 0; use the Total PV Power sensor instead.

  • Fix: house_consumption mirrors solar on SPM 8000TL-HU (Issue #303): The HU variant of the SPH family does not populate power_to_load or power_to_user registers, causing house_consumption to collapse to solar power when both are zero (the simple load = solar fallback). Fixed with a full energy balance fallback: when battery or grid data is present, house_consumption = solar + battery_discharge − battery_charge + grid_import − grid_export. With the HU test case (solar 2389 W, import 2801 W, discharge 501 W) this now correctly computes ≈ 5691 W instead of 2389 W.

  • New profile: MIC 2500-5500MTL-S (Issue #304): Added support for the MIC 2500–5500MTL-S single-phase dual-string grid-tied inverter family (2.5–5.5 kW, legacy V3.05 protocol). Inherits the MIC 600–3300TL-X register map with PV2 voltage and current confirmed at regs 7–8. PV2 power pair at regs 9–10 is included but unconfirmed — if the PV2 Power sensor shows an unrealistic value, those registers contain firmware version bytes and should be reported via the issue tracker. Auto-detected via DTC 210 at holding register 43. Note: this inverter rejects multi-register Modbus block reads — use block_size=1 with the Universal Scanner service.


v0.9.1b1

Issues: #302

We apologise for this one. The Grid Export Power and Grid Import Power sensors have had their values swapped since they were introduced, meaning every user has been seeing export labelled as import and vice versa. The bug was in the formula that splits the signed grid power value into its two always-positive halves — the positive and negative parts were extracted into the wrong sensors. The signed Grid Power sensor and all daily energy sensors were unaffected because they use a different code path. We only caught it because a user noticed the symptom on a hybrid inverter where both directions are active (Issue #302). Grid-tied string inverter users (MIN, MID, MIC) were also affected but the symptom was less obvious — those inverters only export during the day, so Grid Export Power silently read zero while Grid Import Power carried the export value. Both are now correct.

⚠️ BREAKING CHANGE — affects all users. Grid Export Power and Grid Import Power were swapped in all previous versions. After upgrading, these sensors will read the opposite value to before. If you have automations, dashboards, or energy dashboard slots referencing either sensor, you must swap them. The signed Grid Power sensor and all daily energy sensors are unaffected. Users with Invert Grid Power enabled should also disable it (Settings → Devices & Services → Growatt Modbus → Configure) — it was incorrectly set by auto-detection in previous versions and is no longer needed for standard inverters.

  • Breaking fix: grid_export_power and grid_import_power swapped on all profiles (Issue #302): The two always-positive derived power sensors had their formulas inverted in all previous versions. grid_export_power was extracting the import portion of the signed grid power value and grid_import_power was extracting the export portion — the opposite of their names. On hybrid profiles (SPH, MOD, WIT) the symptom was visible: during grid import, grid_export_power showed the import magnitude while grid_import_power read zero. On grid-tied string inverters (MIN, MIC, MID) the inverter only exports, so grid_export_power silently read zero and grid_import_power showed the export value under the wrong name. The signed grid_power sensor and the daily energy sensors (Energy to Grid Today, Grid Import Energy Today) were unaffected — they read from separate register addresses.

  • Fix: invert_grid_power auto-detection was inverting the wrong case: The setup wizard's grid orientation detection returned the wrong result — it enabled inversion when it detected positive = export (the correct convention) and disabled it when it detected negative = export (the case that actually needs correction). This caused some users to have invert_grid_power incorrectly set to True, which negated the signed grid_power sensor so it showed negative while exporting. Auto-detection is now correct. Existing users with the flag incorrectly enabled should disable it via Configure.


v0.9.0


  • Fix: Universal Scanner DTC registers showing as zero on fresh TCP connection: The DTC identification registers (holding 30000 and holding 43) frequently returned 0 in scan output even though read_register always worked. The scanner opens a new raw TCP connection that displaces the coordinator's session; the inverter returns 0 until it settles. Fixed with a post-connect warmup delay and end-of-scan settled re-reads — by the time the full range scan completes, several seconds have elapsed and the inverter's Modbus state is stable. Also fixes garbled firmware version (holding 9-11) from the same cause.

  • Fix: VPP battery charge/discharge today swapped on SPH V2.01 profiles (Issue #300): battery_charge_today and battery_discharge_today from VPP registers 31202 and 31206 were labelled the wrong way round on sph_3000_6000_v201 and sph_7000_10000_v201. VPP Protocol V2.01 specifies 31202 as daily charge and 31206 as daily discharge — the integration had them reversed. The legacy storage-range registers (1052/1053 and 1056/1057) were always correct; only the VPP-sourced entities were affected.

  • Feature: Universal Scanner now includes holding register scan (0-124 and 1000-1124): The export_register_dump scanner now reads holding registers (FC03) for the legacy base range (0-124) and storage/control range (1000-1124) in addition to the existing input register scan. These ranges contain writable controls such as ac_charge_enable (holding 1092), TOU time period slots (holding 1100-1108), charge/discharge power rates, priority mode, and scheduling windows. Holding register rows appear in the CSV with an H-prefix address (e.g. H1092) and a Suggested Match column populated from the active profile's register definitions. Holding and input data are kept in separate dictionaries so values at the same address do not overwrite each other.


v0.8.9

Issues: #295


  • Fix: WIT all entities unavailable after upgrading to v0.8.8 (Issue #295): The profile-driven register scan sizing introduced in v0.8.8 contained a bug affecting WIT inverters. Two related problems were found and fixed:

    1. has_base_range was checking for any address in 0–999, which includes WIT's 875-range registers. This caused max_base_addr to resolve to ~998 — a 999-register read that immediately exceeded the Modbus limit of 125 per request. Fixed by excluding 875–999 from the base range check (that range is already read separately).
    2. After the first fix, the base range read was still 189 registers (WIT has input registers defined up to address 188). This also exceeds the 125-register limit. Fixed by reading the base range in 125-register chunks when it spans more than 125 addresses — the same pattern already used for the 3000-range. As a side effect, WIT registers 125–188 are now read correctly for the first time (previously the 0–124 cap silently dropped them).
  • Feature: Universal Scanner configurable block size: The growatt_modbus.export_register_dump service now accepts a Block Size field (125, 25, or 1 register per request; default 125). Inverters using older RS485 protocols or single-register-only firmware (such as the TL3-S family) reject large Modbus block reads and return Illegal Function errors for entire ranges. Setting block size to 25 or 1 allows these inverters to be scanned successfully, at the cost of scan time.

  • Feature: Universal Scanner always reports both DTC registers: The scan result notification and CSV detection section now always show the raw value of both the VPP DTC register (holding 30000) and the legacy V1.39 DTC register (holding 43), regardless of which one was used for model identification. Useful when investigating inverters with unknown or conflicting DTC codes.


v0.8.8

Issues: #294


  • Feature: Configurable inter-request Modbus delay (Issue #294): A new Modbus Request Delay field (50–1000 ms, default 250 ms) is available in Options (Settings → Devices & Services → Growatt Modbus → Configure). This controls the minimum pause between consecutive Modbus read requests within a single poll cycle. The 250 ms interval was already hardcoded internally; this exposes it as a user-configurable setting. Users seeing transaction_id mismatch errors in the log — caused by the inverter responding late to requests while the next one has already been sent — should increase this to 500–1000 ms. Takes effect immediately without an integration restart.

  • Fix: Profile-driven input register block sizing: The base (0–N) and storage (1000–N) input register reads now read only up to the highest register address defined in the active profile, rather than always reading 125 registers. A profile that only uses registers 0–88 now requests 89 registers instead of 125, reducing payload size and poll time.

  • Fix: VPP holding register retry throttling: VPP-range holding registers (30100, 30200–30201, 30407–30410) that return no response on the first read of a session are now permanently skipped for the remainder of that session. This mirrors the existing behaviour for VPP input register ranges and prevents repeated unanswered requests from accumulating transaction-ID mismatches on firmware that does not implement these registers. On the next HA restart the registers are retried once in case firmware was updated.

  • Fix: priority_mode sensor displays mode name instead of raw integer: The Priority Mode sensor now shows "Load First", "Battery First", or "Grid First" instead of the raw register value (0, 1, 2).

  • Feature: Export Limit Fallback Power Rate writable number entity (holding register 3000): A new Export Limit Fallback Power Rate number control (0–100%, step 0.1) is available on MIN TL-X, MIN TL-XH, MIC 600–3300TL-X, and TL-XH 3000–10000 profiles (and all their V2.01 variants). It reads and writes holding register 3000 (ExportLimitFailedPowerRate) — the fallback output power cap the inverter applies when export limitation control fails. Appears under the Grid device as a configuration entity.


v0.8.7

Issues: #286, #287, #293


  • Fix: priority_mode (register 1044) demoted from writable select to read-only sensor (Issue #293): V1.39 protocol specifies holding register 1044 as read-only. The integration incorrectly exposed it as a writable select entity on SPH 3–6kW, SPH 7–10kW, and SPH-TL3 profiles, allowing writes that the inverter silently ignores or rejects. Register 1044 is now a read-only diagnostic sensor (Battery device) on all affected profiles. WIT (register 30476) and MOD (input register 3144) were already read-only and are unchanged.

  • Feature: SPH V2.01 remote power control registers (Issue #286): VPP registers 30407–30410 are now exposed on the sph_3000_6000_v201 and sph_7000_10000_v201 profiles as writable entities. Register 30407 (remote_power_control_enable, on/off select), 30408 (remote_power_control_charging_time, 0–1440 min number), 30409 (remote_charge_and_discharge_power, −100 to +100% number), and 30410 (vpp_ac_charge_enable, disabled/PV priority/AC priority select) allow time-limited charge/discharge power overrides and AC charging mode control from Home Assistant automations — the same capability available in the Growatt SHINE app.

  • Feature: Battery voltage range option in integration settings: A new Battery Voltage Range dropdown has been added to the integration's Options flow (Settings → Devices & Services → Growatt Modbus → Configure). Three choices are available: Auto-detect (default, suitable for most installations), Standard battery (under 600 V) (forces register 3169 to be read at 0.01 V/unit with no overflow correction), and High-voltage battery (600–950 V, e.g. ARK) (applies an overflow correction to register 3169 when its reading is below 100 V — the symptom of a 16-bit overflow on HV systems where VPP register 31214 does not respond). Useful when the auto-detection cascade gives an incorrect result and the user knows their battery type.

  • Feature: MID TL3-X V2.01 PV3 string sensors added: The mid_15000_25000tl3_x_v201 profile now includes PV string 3 sensors (pv3_voltage, pv3_current, pv3_power) sourced from VPP registers 31018–31021. The total PV power register shifts to 31022–31023 (matching the VPP Protocol V2.01 3-string block layout). The legacy (non-VPP) MID profile is unchanged — PV3 data is only available via VPP registers.

  • Fix: MOD TL3-XH battery voltage 10× too high on standard (non-HV) battery systems (Issue #287): v0.8.0 changed register 3169 scale from 0.01 to 0.1 to correct readings on high-voltage ARK battery systems (600–950 V). This broke MOD TL3-XH units with standard 200–300 V batteries, which store voltage in 0.01 V/unit resolution — producing readings 10× too high (e.g. 2500 V instead of 250 V). Register 3169 reverted to 0.01 V/unit scale. VPP register 31214 (0.1 V/unit, per VPP Protocol V2.01) added as a higher-priority candidate via the existing max-value selection logic: when 31214 responds it correctly covers both HV (600–950 V) and standard-voltage batteries regardless of 3169's unit resolution. The battery voltage plausibility ceiling has also been raised from 800 V to 1100 V so that valid HV readings are not discarded.


v0.8.5

Issues: #228 · #242 · #284 · #285


  • Fix: MOD TL3-X and TL3-XH ac_power reported Phase R only (Issue #228): Both profiles had the alias: 'ac_power_high/low' on registers 40/41 (Phase R output power) instead of registers 35/36 (three-phase total output power). As a result ac_power always equalled ac_power_r regardless of the other phases. Alias moved to registers 35/36 in both profiles.

  • Fix: Midnight ENERGY_GUARD incorrectly retained previous-day small daily totals: After HA midnight the daily retention dict is cleared. The first poll (typically 7 seconds later) catches the inverter before it has reset its own counters (~30–90 s after HA midnight). Daily totals under the 20 kWh spike threshold (e.g. charge_energy_today, load_energy_today) were being accepted into retention as legitimate new-day values. When the inverter subsequently reset them to 0, the retention logic held the stale yesterday values for the rest of the night. At sunrise the hardware value rose past 0 and the guard silently dropped retention, causing a backward step on total_increasing sensors and HA recorder warnings. Fixed by opening a 10-minute grace window at midnight during which any non-zero daily total with no prior retention is suppressed to 0. The inverter's own reset always completes within this window; genuine new-day accumulation starts cleanly after it expires.

  • Feature: Inverter clock drift detection and HA notification: On the first successful connection each HA session the coordinator reads the inverter's system time registers (VPP 2.01: holding 30104–30109; V1.39/OffGrid: holding 45–50) and compares to HA system time. If the absolute drift exceeds 5 minutes a persistent HA notification is created explaining the impact on daily energy counters and how to correct the inverter clock.

  • Breaking change: MID TL3-X grid export/import now sourced from Meter Power register (Issue #242): grid_export_power and grid_import_power on MID grid-tied models (MID 15–50KTL3-X, MID 20–30KTL3-X2, MOD/MID-X3 series — DTC 5001/5002) previously read from VPP Active Power register 31100/31101, which is the inverter's own 3-phase AC output. For a grid-tied inverter without a built-in CT clamp this overstated export (inverter output vs. actual grid exchange). Grid export/import now correctly sources from VPP Meter Power register 31112/31113, which reflects the value measured by a connected Growatt smart meter or datalogger. If you have no external smart meter, these entities will read 0 — use ac_power or solar_total_power for inverter output monitoring instead. Hybrid models (SPH, MOD-XH, WIT) are unaffected: their Active Power register already carries net grid exchange computed by the hybrid firmware.

  • Fix: Daily energy totals drop to 0 then show backward steps after mid-day inverter reconnect (Issue #284): When the inverter briefly goes offline mid-day (grid disturbance, fault recovery, peak shaving) and comes back online, the wakeup handler was unconditionally clearing ENERGY_GUARD retention. The first post-reconnect poll would read 0 for daily counters (inverter not yet done repopulating its registers), and with no retention to hold the previous value the sensor dropped to 0. Subsequent polls recovered to a value slightly below the pre-offline reading, causing a backward step and HA total_increasing recorder warnings. Fixed by gating the retention clear on time of day: retention is only cleared on wakeup before 10:00 (morning startup where stale-value detection is needed). Mid-day wakeups preserve retention so ENERGY_GUARD continues protecting against transient 0-reads. The morning stale-value detection path (Issue #225) is unaffected — _handle_midnight_reset() already clears retention at midnight before the inverter comes online.

  • Fix: DTC code 5001 misdetected as MIC instead of MID (Issue #242): DTC 5001 was absent from the detection map, causing MID 17–25KTL3-X and related grid-tied MID/MOD-X models to fall through to MIC micro-inverter profile detection. All missing DTC codes from Growatt VPP 2.03 protocol Table 3-1 have been added: 5001/5002/5003 (MID/MOD/MAC-X grid-tied series), 5600/5801 (large WIT/WIS commercial), 3503/3504 (SPH HU/HUB variants), 3701/3715/3716 (SPA AU/AUB/BL variants). Users who were manually selecting a profile to work around wrong auto-detection can re-run auto-detect after updating.

  • Fix: Lifetime energy totals show brief backward step after HA restart (Issue #285): energy_total, charge_energy_total, discharge_energy_total and similar lifetime counters are persisted to HA storage so they survive restarts. Previously the save was dispatched as a background task; if HA restarted before the task executed, the storage held the value from the previous poll cycle. On restart HA briefly displayed the older value before the next live poll corrected it, causing a total_increasing backward-step warning in the recorder. Fixed by awaiting the storage write directly after each poll where retention values change, so storage is always current within the same event-loop tick. The HA Store debounces disk I/O internally, so this adds no meaningful overhead.


v0.8.4


  • Debug: [ENERGY_GUARD] diagnostic logging added to energy protection (Issue #228): The daily energy counter protection logic now emits searchable [ENERGY_GUARD] log entries at DEBUG level. Each poll logs whether a daily total was accepted, retained (hardware reported 0), or spike-rejected. The wake-up retention-clear event logs the discarded values before wiping them. The stale-value debounce window now logs energy_to_user_today alongside energy_today. Enables root-cause diagnosis of gradual overnight accumulation followed by a morning drop-to-zero on inverters that stay partially online at night (e.g. MOD12-KTL3-HU). To enable, set custom_components.growatt_modbus: debug in your HA logger config and search logs for ENERGY_GUARD.

v0.8.3


  • Fix (Issue #283): SPH 3–6kW and 7–10kW battery registers corrected: Input registers 13–19 in the 0–124 base range were incorrectly named as battery registers (battery_voltage, battery_current, battery_power, battery_soc, battery_temp, bms_type). Per V1.39 protocol those addresses are PV3–PV5 channel registers (power H/L words for additional PV strings). Battery data is exclusively in the storage range: discharge power (1009–1010), charge power (1011–1012), battery voltage (1013), SOC (1014), battery temperature (1040). All six wrong definitions removed; registers 1013 and 1040 added. V201 override that shadowed the old spurious battery_soc at register 17 also removed.

v0.8.2


  • Fix: set_battery_mode service was a registered no-op (F-001/F-002): The VPP battery-mode write logic had been spliced into get_register_data by mistake, leaving set_battery_mode as a function that only logged one line and returned. The _read() closure and return payload belonging to get_register_data had been appended to sync_tou_schedule, causing a runtime NameError on the success path. All three function bodies restructured so each contains only its own logic.

  • Fix: services.yaml field mismatches corrected (F-006/F-007): Three phantom services (read_inverter_data, test_connection, update_register_map) removed — they were documented but never registered. set_battery_mode fields restored (device_id selector + mode + power_percent). write_registers fields corrected (register + values). sync_tou_schedule no longer has orphaned write_registers fields at the end.

  • Fix: Holding register reads omitted slave/unit ID (F-003): read_holding_registers() now passes slave_id using the same try/except compatibility fallback (slave=, unit=, positional) already used by read_input_registers. Five direct client.client.read_holding_registers() calls in auto_detection.py switched to the wrapper method.

  • Fix: WIT cooldown timestamp set before write (F-005): _wit_control_last_write[register] is now updated only after a confirmed successful write. Previously a failed write would still block subsequent writes for the full 30-second cooldown.

  • Fix: Binary sensor online state now uses coordinator.is_online (F-018): Replaced the 5-minute timedelta heuristic with the coordinator's authoritative is_online property, keeping inverter connection state consistent across all platform entities.

  • Fix: Duplicate modbus_client property removed from coordinator (F-021): The property was defined twice in GrowattModbusCoordinator; the second definition shadowed the first silently.

  • Fix: Explicit disconnect() added to entry unload path (F-022): async_unload_entry now calls coordinator.modbus_client.disconnect() via executor before removing the coordinator from hass.data. Prevents file descriptor leaks on integration reload.

  • Docs: battery-scheduling.md service examples corrected (F-008): Two read_register YAML examples used register_address and count which are not part of the service schema. Fixed to register; count removed; device_id moved into data block.

  • Feat (Issue #282): WIT holding registers 235–238 exposed as read-only diagnostic sensors: ntognd_detect (235), nonstd_vac_enable (236), enable_spec_set (237), and fast_mppt_enable (238) are now readable as diagnostic sensors on the Inverter device. All four are read-only in this integration regardless of the hardware's write capability. Registers 235–238 control safety-critical grid-protection and inverter behaviour (N-to-GND detection, non-standard grid voltage thresholds, regional spec flags, and MPPT aggressiveness). Writing incorrect values can cause grid-code violations, hardware damage, or void certification. All four entities are disabled_by_default and require explicit opt-in to surface in the UI.

  • Fix (Issue #131): grid_first_discharge_power_rate range corrected to 1–100%: Register 3036 (Grid First discharge power rate on MOD TL3-XH) was documented as 1–255 in the protocol sheet but user-confirmed to be a percentage — values above 100 produce an unknown error response from the inverter. The number entity range is now clamped to 1–100% to prevent out-of-range writes.


v0.8.1


  • Fix: Daily energy spike at inverter startup eliminated (Issue #228): Some inverters write 32-bit register pairs as two separate 16-bit writes. During the midnight daily counter reset, reading the pair mid-write produces a transient garbage value (e.g. 79 kWh when the true value should be ~0 kWh). The coordinator's _protect_energy_totals function previously accepted any positive reading unconditionally, so the garbage value was stored as the day's retained total, causing the sensor to stay at that spike value. Added a rate-of-change guard: any daily counter jump larger than 20 kWh in a single poll is rejected with a WARNING log entry. The 20 kWh threshold is safe for any poll interval and any residential or commercial system size.

v0.8.0


  • Fix: MOD TL3-XH battery voltage scale corrected (Issue #228): Register 3169 (battery_voltage) scale changed from 0.01 to 0.1. The MOD TL3-XH hardware operates at 600–950 V — a 16-bit register with 0.01 V resolution overflows above 655 V, making the previous scale physically impossible for any battery in this inverter's operating range. Affected users saw values ~10× too low (e.g. 73 V instead of 733 V). The Growatt V1.39 protocol spec lists 0.01, which applies to lower-voltage hardware variants; the XH spec sheet (600–950 V) confirms 0.1 is correct for this profile.

  • Feat: MOD TL3-XH battery mode power rate controls (Issue #131): Two new writable holding registers added to MOD_6000_15000TL3_XH:

    • grid_first_discharge_power_rate (register 3036, range 1–255) — sets the discharge power rate when operating in Grid First priority mode.
    • batt_first_charge_power_rate (register 3047, range 1–100%) — sets the charge power rate when operating in Battery First priority mode. Both appear as number entities in Home Assistant under the Battery device. Confirmed responding on hardware via scan #228 (3036=100, 3047=80).
  • Refactor: VPP V2.01 shared register block extraction (Phase 3): Introduced profiles/vpp_v201.py containing eight shared register block dicts (VPP_V201_STATUS, VPP_V201_PV2_INPUT, VPP_V201_PV2_TOTAL, VPP_V201_PV3_AND_TOTAL, VPP_V201_ENERGY_1P, VPP_V201_TEMPERATURE_1P, VPP_V201_BATTERY2, VPP_V201_HOLDING_1P) covering registers 30099–30201 and 31000–31322. These blocks are identical across the SPH, MIN, TL-XH, SPH-TL3, and MID V2.01 profiles. Each profile now unpacks shared blocks with ** and keeps only family-specific registers inline. Net: −441 lines removed, +273 added (−168 net). No runtime behaviour change.

    Additionally fixed two omissions in the SPH-TL3 V2.01 profile discovered during scan evidence review:

    • ipm_temp_vpp (31131) and boost_temp_vpp (31132) were absent — scans 251_1/251_2 confirm both registers respond (Read OK). Now included via VPP_V201_TEMPERATURE_1P.
    • active_power_rate_vpp (30114) was absent from holding registers — scan confirms it responds (Read OK). Now included via VPP_V201_HOLDING_1P.

v0.7.9


  • Feat: GitHub Pages documentation site: Full documentation migrated to MkDocs at 0xaha.github.io/Growatt_ModbusTCP. Covers supported models, sensor reference, power flow glossary, inverter controls, energy dashboard setup, troubleshooting, and developer guides. README slimmed to installation essentials with a prominent link to the docs.

  • Feat: Register read and disconnect log messages promoted to INFO: The "Successfully read N registers from M" and "Disconnected successfully" messages were previously DEBUG-only, so a successful poll cycle was invisible at default log level. Both are now INFO, consistent with the "Successfully connected" message that was already INFO. Users can now confirm polling is working from the standard HA log without enabling debug mode.

  • Refactor: Template-generated sensor definitions (Phase 2 architecture review): PV string (pv1/pv2/pv3 voltage, current, power) and three-phase AC sensors (ac_voltage/current/power_r/s/t, ac_voltage_rs/st/tr) replaced with helper functions _pv_string_sensors(), _phase_sensors(), and _line_voltage_sensors() in sensor.py. Reduces ~100 lines of verbatim repetition. A grep-index comment block above the helpers lists all generated keys so static analysis tools (including the CI tests) can locate them. CI test updated to also parse grep-index comment lines when extracting sensor definitions.

  • Refactor: Profile key alias mechanism (Phase 2 architecture review): PROFILE_ALIASES: Dict[str, str] added to device_profiles.py. Maps retired or duplicate profile keys to their canonical replacement, allowing profile consolidation without breaking existing config entries. resolve_profile_alias() helper added; get_profile() resolves aliases transparently at runtime. Config entries with aliased keys are silently updated on startup with an INFO log entry. First alias: mod_6000_15000tl3_xh_v201mod_6000_15000tl3_xh (both keys use MOD_6000_15000TL3_XH register map and identical sensors).


v0.7.8


  • Feat: INFO-level startup logging in coordinator: On startup the coordinator now logs a single INFO line summarising the active profile name, connection string (TCP host:port or Serial path@baud), scan interval, and polled register ranges (e.g. 0–124, 1000–1124). A second INFO line is emitted once device identification completes, showing model, serial, firmware, and protocol version. Useful for confirming the correct profile was detected without enabling full debug logging.

  • Feat: CI sensor integrity tests (pytest): Three automated tests in tests/test_sensor_integrity.py verify internal consistency of the sensor configuration on every push and PR to main:

    1. Every key in SENSOR_DEFINITIONS (sensor.py) is assigned to a device in SENSOR_DEVICE_MAP (const.py).
    2. Every key in a *_SENSORS group constant (device_profiles.py) exists in SENSOR_DEFINITIONS.
    3. SENSOR_DEVICE_MAP does not accumulate new undefined-sensor entries beyond a tracked allowlist (KNOWN_MAP_WITHOUT_DEF).

    A .github/workflows/tests.yaml workflow runs these tests on Python 3.12.

  • Fix: Add missing SENSOR_DEFINITIONS for three-phase line-to-line voltages: ac_voltage_rs, ac_voltage_st, ac_voltage_tr were wired end-to-end (GrowattData dataclass, coordinator, profiles, THREE_PHASE_SENSORS group, SENSOR_DEVICE_MAP) but lacked entries in SENSOR_DEFINITIONS, so no sensor entities were ever created. Added as diagnostic voltage sensors.

  • Chore: Remove orphaned SENSOR_DEVICE_MAP entries: bms_status_old, bms_error_old, bms_warn_info_old are superseded legacy BMS register variants with no active sensor definitions; removed from the map.

  • Fix: V2.01 profile incorrectly assigned to non-VPP inverters: Before this release, auto-detection used auto_detected=True as evidence of V2.01 protocol support. That flag is set for any successful detection (including plain register probing), so inverters that use only the legacy 3000-range registers (e.g. MIN 7000-10000TL-X) were silently assigned a _v201 profile and generated Modbus Error: Illegal Function every poll cycle.

    Root cause: supports_v201 in the config flow was derived from auto_detected, not from whether a DTC code was actually read from register 30000.

    Fix: A new vpp_protocol_confirmed flag is stored in config entry data. It is True only when auto-detection successfully read DTC from register 30000 (confirmed V2.01 hardware). The manual-selection and reconfigure flows now read this flag instead of inspecting the current profile name.

    Automatic migration: On startup, async_setup_entry detects the _v201-but-unconfirmed combination and silently downgrades the profile to its legacy equivalent. Affected users will see a one-time WARNING log entry. Legitimate V2.01 users (who set up under v0.7.8+) are not affected because their vpp_protocol_confirmed flag is True.


v0.7.7


  • Refactor: Composite sensor group constants (phase 1 of architecture review): 17 of 28 inverter profiles previously repeated identical 10–13 line sensor union expressions verbatim. Three composite constants now capture the common patterns:

    • GRID_TIED_1P_SENSORS — single-phase grid-tied base (no battery); used by MIN profiles
    • HYBRID_1P_SENSORSGRID_TIED_1P_SENSORS | BATTERY_SENSORS; used by SPH and TL-XH
    • HYBRID_3P_SENSORS — same scope as HYBRID_1P_SENSORS with THREE_PHASE_SENSORS replacing BASIC_AC_SENSORS; used by SPH-TL3 and MOD-XH

    Profile compositions now read as single expressions, e.g. HYBRID_1P_SENSORS | PV3_SENSORS instead of a 12-line union. Adding a sensor to a shared cluster is now one line instead of up to 8. No entity IDs, sensor keys, or runtime behaviour changed — the resolved sets are identical to before. 11 profiles with unique compositions are left as explicit inline blocks.

    Net change: −201 lines in device_profiles.py.


v0.7.6


  • Refactor: Extract SPE_OFFGRID_SENSORS constant (phase 1 of architecture review): The spe_8000_12000_es profile previously used an anonymous inline sensor set for its SPF-compatible sensors. This meant any future change to SPF_OFFGRID_SENSORS would silently not apply to SPE, making the divergence invisible at review time. Extracted to a named SPE_OFFGRID_SENSORS constant with comments documenting which SPF sensors are excluded and why (register overflow, no generator input, remapped registers). No runtime behaviour change — the resolved sensor set is identical to before.

  • Audit: SPA duplicate profile key (architecture review Concern C): Confirmed spa_3000_6000_tl_bl has a single entry in INVERTER_PROFILES. Concern C from the architecture review is not present in the current codebase.


v0.7.5

  • Fix: SPH-TL3 ac_power_s and ac_power_t always showing 0 (Issue #265): On some SPH-TL3 firmware variants, per-phase power registers for phases S and T (registers 44/45 and 48/49) return 0 while voltage and current registers for all three phases report valid data. Only the phase R power register (40/41) was populated — which on this device holds the inverter's total output power rather than a true per-phase R value, making the three phase power readings inconsistent.

    Fix: The coordinator now reads all three per-phase power registers together and checks whether all return valid (non-zero) data. If any are missing or zero, it falls back to calculating apparent power (V×I) for all three phases so the values are consistent with each other. For hardware with fully-functional per-phase power registers (e.g. MOD series), this path is never taken and behaviour is unchanged. For SPH-TL3 users, ac_power_s and ac_power_t will now show realistic per-phase apparent power values instead of 0.


v0.7.4


  • New: Per-string daily and lifetime energy sensors across all compatible profiles (Issue #265): pv1_energy_today and pv2_energy_today sensors are now created for all profiles that support multiple PV strings (SPH, SPH-TL3, MIN, MIC, MOD, WIT, TL-XH). pv3_energy_today is additionally created for 3-MPPT profiles (MIN 7-10kW, SPH 7-10kW, SPH-HU, MOD, TL-XH), but only exposed as an entity when the inverter actually reports non-zero PV3 data.

    pv1_energy_total and pv2_energy_total (lifetime per-MPPT totals) are now exposed for all profiles with legacy registers 59–66: SPH, SPH-TL3, TL-XH, MOD, WIT, and MIN TL-X. MIN TL-X also adds pv3_energy_total via its 3000+ range registers (3057–3066). All totals are condition-gated and only appear once the inverter reports non-zero data.

  • Fix: Incorrect register mapping for SPH and TL-XH legacy registers 59–62: Registers 59–62 in the SPH and TL-XH profiles were incorrectly labeled as backup_voltage/current/power/frequency. Scan data confirmed these are actually per-MPPT DC energy registers (identical to all other Growatt families): 59/60 = pv1_energy_today, 61/62 = pv1_energy_total. No HA entities were ever wired to the old backup names so there is no user-visible regression; the fix corrects the underlying register map and enables the per-MPPT energy sensors for SPH and TL-XH users.

    All per-string sensors are disabled by default — enable them individually in the Home Assistant entity registry if you want to track per-string production. Total daily solar energy continues to be reported by the existing energy_today sensor.

  • Fix: VPP registers 31118–31125 in SPH-TL3 V201 profile had incorrect names and units: These registers were previously mapped as load power (W) and a generic energy_today, causing confusion with the main energy_today sensor. They now correctly map to:

    • 31118/31119 → energy_to_user_today_vpp (kWh, daily energy delivered to loads)
    • 31120/31121 → energy_to_user_total_vpp (kWh, lifetime energy delivered to loads)
    • 31122/31123 → energy_to_grid_today_vpp (kWh, daily energy exported to grid)
    • 31124/31125 → energy_to_grid_total_vpp (kWh, lifetime energy exported to grid)

    These VPP registers are suffixed (_vpp) so they do not interfere with the legacy protocol registers which take precedence during coordinator data resolution.

  • Fix: Today energy sensors reset to 0 on any HA restart or integration reload: On every cold-start (HA restart or config-entry reload), _previous_day_totals is empty because it is only populated at midnight during an active session and is never persisted to storage. The stale-value debounce introduced in v0.7.3 (Issue #225) always ran on the first inverter connection after startup, comparing the inverter's current energy_today against an effective "yesterday = 0". This produced two classes of false positive:

    1. Small legitimate morning values (0 < energy_today < 0.1 kWh) matched the "within 0.1 kWh of yesterday" tolerance and were zeroed out.
    2. Large mid-day values on higher-capacity systems (e.g. 18+ kWh by 9 AM on a 15 kW system) exceeded the 2 kWh/hour rate heuristic and were also zeroed out.

    In both cases the sensor showed 0 (with the inverter online and available = True), causing HA long-term statistics to record a spurious counter reset.

    Fix: The stale-value debounce window (_just_came_online_time) is now armed only when _ever_had_real_data = True — meaning HA has been running continuously since the last midnight reset and _previous_day_totals actually holds a real yesterday reference. On cold-start, the debounce is skipped entirely; storage-loaded retention already protects against glitch zeros, and without a genuine yesterday total the stale check produces only false positives.

  • Fix: MIN TL-XH pv_energy_total missing on some firmware variants: On the MIN TL-XH 3000-10000 (V2.01) profile, the primary PV lifetime energy register (3053/3054, Epv_total) was not present in the profile definition — meaning pv_energy_total was always zero or absent. Additionally, some hardware/firmware variants that do expose 3053/3054 report 0 there while holding the correct accumulated value in the legacy register pair 91/92 (same as TL-XH 0-range layout).

    Fix: Registers 3053/3054 are now declared as primary pv_energy_total_high/low in the MIN_TL_XH_3000_10000_V201 profile, matching the layout of the MIN grid-tied 3000-range profiles. Registers 91/92 are declared as pv_energy_total_legacy_high/low. The reader falls back to the legacy pair only when the primary read returns exactly 0 and the legacy registers contain a non-zero value — so genuinely zeroed systems are unaffected while firmware variants that use 91/92 get a valid reading.

  • Fix: Condition-gated sensors permanently missing after any HA restart (#262): The v0.7.3 fix for issue #255 introduced async_config_entry_first_refresh, which seeds coordinator.data with an empty GrowattData() placeholder — without ever reading the inverter — so that HA's bootstrap stage completes immediately regardless of inverter connectivity. However, sensor and control entity setup runs against this placeholder, so any entity whose creation is gated on a runtime-detected hardware attribute (e.g. hasattr(data, 'battery_soh')) sees no data, fails the check, and is permanently skipped for the entire HA session.

    This affected every startup, not only ones where the inverter was offline. A fresh install with the inverter fully online still produced the same result because the placeholder is always seeded before the first poll.

    Affected entities (examples): battery_soh, bms_soh, battery_voltage_bms, vpp_export_limit_enable, control_authority, generator sensors, extra temperature sensors, and any other entity whose presence depends on a register that is confirmed by a live hardware read.

    Fix: deferred entity registration. After the initial setup pass, each affected platform (sensor, select) now registers a lightweight coordinator listener. The listener is a no-op until coordinator.has_real_data becomes True (the inverter's first successful poll). At that point it re-evaluates the skipped conditions against real data, calls async_add_entities for any that now pass, and unsubscribes itself. Existing entities are never disrupted. The listener is also cleaned up automatically if the config entry is removed before the inverter ever responds.


v0.7.3

Issues: #249 · #253 · #254 · #255 · #256 · #257 · #225 · #259


  • SPH-TL3 / SPA — Battery First & Grid First TOU scheduling (#249): The SPA/SPH-TL3 firmware has a full time-of-use schedule with separate windows for Battery First and Grid First modes, beyond the 3 AC-charge slots already available. These registers were confirmed via the SPH_3000-6000TL-HUB user manual and hardware register scan.

    27 new control entities are now exposed for SPH-TL3 and SPA (which inherits the same register map):

    Slot Mode Start End Enable
    4–6 Battery First reg 1017/1020/1023 reg 1018/1021/1024 reg 1019/1022/1025
    4–6 Grid First reg 1026/1029/1032 reg 1027/1030/1033 reg 1028/1031/1034
    7–9 Grid First reg 1080/1083/1086 reg 1081/1084/1087 reg 1082/1085/1088

    Time slots appear as time entities (HH:MM picker); enable toggles appear as select entities (Enabled / Disabled).

    Background: Writes to priority_mode (reg 1044) were silently rejected by the SPA firmware when all Battery First and Grid First scheduling windows contained zeros. The ShinePhone workaround (set all slots to 00:00–23:59) works by populating these window registers. With this release, the slots can be configured directly from Home Assistant, eliminating the need for the workaround.

  • SPH-TL3 — Power to Load / Grid Power register fix (#257, @TomasHala): Registers 1021/1022 (power_to_user_total) and 1037/1038 (power_to_load) were swapped in the SPH-TL3 profile. Grid import power and load consumption are now correctly separated. Hardware-tested on SPH-TL3.

  • SPH-TL3 — New control entities (#256, @TomasHala): Four additional holding registers added, hardware-tested on SPH-TL3. These are already available in the SPH profile and are now exposed for SPH-TL3 (and SPA, which inherits the same register map):

    • Max Output Power Rate (reg 3) — limits AC output power as % of rated capacity
    • Export Limit Mode (reg 122) — enables/disables grid export limiting
    • Export Limit Power (reg 123) — export power cap as % of rated capacity
    • Load First Battery Minimum SOC (reg 608) — minimum SOC before switching to load-first mode
    • Battery State of Health (reg 31218) — BMS-reported battery health percentage (read-only)
  • Translations — 20 languages (#254): UI config flow and options strings are now available in 20 languages. Danish (da) was contributed by a community member; the remaining 19 were added in this release:

    Code Language Code Language
    de German cs Czech
    nl Dutch hu Hungarian
    fr French ro Romanian
    es Spanish sk Slovak
    it Italian bg Bulgarian
    pl Polish hr Croatian
    pt Portuguese el Greek
    sv Swedish tr Turkish
    nb Norwegian Bokmål ru Russian
    fi Finnish uk Ukrainian

    The English (en) file remains the authoritative reference.

  • MIN / TL-XH — Eac Total and Epv Total as separate sensor entities (#253): Two distinct lifetime energy figures are now exposed independently:

    • Energy Total (energy_total, reg 3051/3052) — Eac: total AC energy the inverter has ever delivered to the grid and home loads. On hybrid models this includes battery discharge.
    • PV Energy Total (pv_energy_total, reg 3053/3054) — Epv: raw DC energy captured from the solar panels, measured before the inverter conversion stage. Slightly higher than Energy Total due to ~2–7% conversion losses; unaffected by battery charge/discharge cycles.

    pv_energy_total is also available on TL-XH (reg 91/92), SPH, SPH-TL3/SPA, WIT, and MOD-XH profiles. energy_total always reads the AC-output register directly on all profiles — it is never replaced or overridden by the Epv figure.

    Register mappings also added to both MIN profiles for PV3 DC string energy (3063/3064 today, 3065/3066 total) alongside the previously added PV1/PV2 string registers.

    The energy_today per-MPPT summation (pv1 + pv2 + pv3 DC strings) is used on hybrid profiles (SPH, SPH-TL3/SPA, TL-XH, WIT, MOD-XH) where the AC energy_today register includes battery discharge. Pure grid-tied profiles (MIN, MIC) read energy_today directly.

  • Sensor descriptions in More Info modal: Ambiguous or easily confused sensor pairs now display a plain-English explanation in the More Info modal (click any sensor tile in the HA dashboard). Descriptions cover: Energy Today / Energy Total / PV Energy Total, Solar Total Power vs System Output Power, Grid Power (signed) vs Grid Export / Import Power, Battery Power (signed) vs Charge / Discharge Power, battery energy accounting (DC charge/discharge vs AC charge/discharge vs operational discharge), load and grid energy breakdowns, IPM/Boost temperatures, BMS voltage vs inverter-measured voltage, and WIT parallel inverter extra sensors.

  • Offline at startup — integration now loads without blocking HA bootstrap (#255): Two separate startup failure modes are now resolved:

    • ConfigEntryNotReady loop — if _fetch_data returned None (inverter not responding), the coordinator raised UpdateFailedConfigEntryNotReady. HA retries with exponential backoff but can exhaust the retry budget before the inverter comes online (e.g. overnight). Fixed: coordinator creates an empty GrowattData() placeholder instead of failing.

    • CancelledError: Bootstrap stage 2 timeoutasync_config_entry_first_refresh made two blocking executor calls (device identification + data read, each with 3 TCP retries). On a slow or offline inverter this exceeded HA's global bootstrap timeout, cancelling the setup task entirely. Fixed: first refresh now only restores local persisted energy totals (no network I/O). Device identification is read lazily on the first successful poll.

    In both cases the integration loads immediately; all sensors show unavailable until the inverter responds. No manual reload required.

    Also guarded the VPP entity removal logic (vpp_export_limit, control_authority) against the offline-startup case so entities are only pruned when the inverter has actually connected and confirmed those registers are absent.

  • Power sensors show unavailable when inverter is unreachable (#259): Previously, power sensors (PV power, battery power, grid power, load power, etc.) returned 0 W whenever the inverter was not responding. This is misleading — a TCP adapter keeps the socket open even when the RS485 bus to the inverter has no signal, so 0 W is indistinguishable from a genuine zero reading at night.

    Per the HA integration quality scale entity-unavailable and log-when-unavailable rules: entities must report unavailable when data cannot be fetched (not a synthetic 0), and must log at INFO level once on the unavailable→available transition in both directions. Power sensors now return None (→ unavailable) in offline state, consistent with diagnostic and energy sensors. Logging now fires once per state transition at INFO; repeated per-poll errors are demoted to DEBUG.

  • Energy Today — stale overnight value persists until sunrise instead of resetting at midnight (#225): The midnight callback correctly cleared the daily retention store. However, if the inverter stayed connected through midnight (reporting yesterday's accumulated total before its hardware register reset at sunrise), overnight polling would rebuild the retention store with the stale yesterday value. When the hardware finally reset to 0 at sunrise the retention protection would then prevent the 0 from showing, so the sensor displayed yesterday's total all morning.

    Fix: when the inverter comes back online after an offline period, daily total retention is now cleared unconditionally (not just on date change) and the debounce window is always enabled. When the debounce detects a stale value (matches yesterday's final reading) it resets daily totals to 0 and simultaneously clears the retention store so _protect_energy_totals cannot undo the reset.


v0.7.2

Issues: #251 · #249 · #245 · #228


  • MID/MOD V2.01 — corrected VPP 31100-31113 register mappings (#245, #228): The VPP 2.01 protocol specification (confirmed against MID 20KTL3-XH scan data in #245) defines the 31100-31113 range as:

    • 31100/31101: Active power INT32 (positive = export, negative = import) — was previously mapped as per-phase voltages, which is incorrect. Now mapped as power_to_grid fallback.
    • 31105: Grid frequency (×0.01 Hz) — was unmapped; now mapped as ac_frequency_vpp.
    • 31106-31108: AB/BC/CA line voltages (×0.1V) — were unmapped; now mapped as line_voltage_rs/st/tr for three-phase line voltage sensors.
    • 31109-31111: Phase A/B/C currents (INT16 signed, ×0.1A) — were unmapped; now mapped as ac_current_r/s/t.
    • 31112/31113: Meter power INT32 (positive = import per spec item 55) — was incorrectly mapped as power_to_grid fallback (wrong sign direction). Now correctly mapped as power_to_user. This also retroactively fixes the #228 MOD grid power "wrong direction" symptom: the old #228 workaround happened to paper over the issue in some scenarios, but the root cause was using an import-direction register as the export fallback.
    • 31102/31103: Reactive power INT32 (×0.1VA) — added as diagnostic registers.
    • 31118-31125: Energy counters (UINT32, 0.1kWh) — were incorrectly mapped as load power (31118/31119) and solar energy today/total (31120-31123). Per spec items 60-63 these are grid import/export energy today/total. Corrected and 31124/31125 (total grid export) added. The VPP values act as fallbacks behind the 3000-range energy counters (3067-3074) which take priority in the coordinator's multi-range lookup.
  • SPA — additional sensors from extended scan (#249): Cross-analysis of 15 time-of-day scans (09:34–20:41) against energy balance verification confirmed three missing sensors:

    • Grid import power (power_to_user): register 1021/1022 = PacToUser Total (×0.1 W). Confirmed via energy balance: battery_discharge + grid_import = load ✓ at every scan. Note: SPH-TL3 uses the same register addresses (1021/1022) for load power — semantics differ because SPA measures the grid connection point bidirectionally.
    • Grid frequency (ac_frequency): register 1113 (×0.01 Hz). Confirmed 49.86–50.00 Hz variation consistent with UK grid frequency fluctuation.
    • Battery current (battery_current): register 1088 (×0.01 A, signed). Confirmed: +14.0A during 760W charge (÷54.3V = 14.0A ✓); −58.5A during 3050W discharge (÷52.5V = 58.1A ✓). Negative = discharging per HA convention.
  • SPH 10000TL3 BH-UP — wrongly assigned V201 profile (#251): Devices with DTC 3601 that return protocol version 0 from register 30099 (indicating legacy register layout, no V2.01 support) were occasionally auto-detected as sph_tl3_3000_10000_v201 instead of sph_tl3_3000_10000, causing grid_voltage and grid_frequency to read as zero despite the inverter actively exporting power. Two fixes applied: (1) the DTC 3601 refinement step in async_refine_dtc_detection() now explicitly reads register 30099 and returns the base profile immediately if it returns 0, ahead of the general protocol version check; (2) the diagnostic scanner's "Suggested Profile Key" now correctly applies the same protocol-version downgrade logic so scan output matches what actual HA detection would choose (previously the scanner silently skipped register 30099 when its value was 0 due to a falsy-check bug, and returned the V201 profile key before the protocol version block could act on it). Affected users should remove and re-add the integration to trigger fresh auto-detection.


v0.7.1

Issues: #249 · #242 · #212


New Profiles

  • SPA series — new profile (#249): The SPA 3000–6000TL BL (AC-coupled battery storage, no PV MPPT inputs) now has a dedicated profile. Previously it auto-detected as MIN 7000-10000TL-X and all sensors read zero; with SPH-TL3 manually selected, AC voltage, frequency, and load power also read zero because the SPA never populates the 0-124 register range. The new spa_3000_6000_tl_bl profile reads exclusively from the 1000-1124 range where the SPA keeps all its data. Load power is correctly sourced from registers 1037/1038 (SPH-TL3 uses 1021/1022 for this, which are zero on the SPA). Confirmed sensors: battery voltage/SOC/temp/type, charge/discharge power, power to grid, load power, AC voltage (~216V at reg 1105), and the full energy breakdown set (energy to user/grid today/total, battery charge/discharge today/total, load energy today/total). Holding register layout (battery management, TOU time periods) is identical to SPH-TL3.

Universal Register Scanner — Device Selector

The Universal Register Scanner service now has a Device dropdown at the top of the service form. Selecting your configured inverter pre-fills all connection details (IP, port, serial path, baudrate, slave ID) and guarantees that the "CURRENTLY CONFIGURED PROFILE" and "CURRENT ENTITY VALUES" sections appear in the CSV output. Previously, entity values were only included when the scanner could match the connection parameters you typed against a running integration entry, which silently failed for serial connections if the device path differed even slightly. Manual IP/serial entry fields are still available for scanning a new inverter before it has been added to the integration.

Bug Fixes

  • WIT 8K-HU — Battery voltage/current fix (take 2) (#247): The v0.7.0 multi-candidate selection was not actually comparing the VPP register (31214, spurious 5.2V) against the native register (8034, correct 53.7V). The candidate loop used _find_register_by_name_with_fallback() which filters down to a single address based on the detected preferred range — so when the VPP range scored non-zero (because 31214 returns a wrong-but-non-zero value), only reg 31214 was ever evaluated as a candidate and reg 8034 was never read. Fixed by replacing the single-address lookup with _find_all_registers_by_name() so every matching address across all ranges is evaluated. The 5.2V value at reg 31214 is then correctly discarded by the 10V plausibility floor and the 53.7V from reg 8034 is selected. The same fix is applied to battery current.

Profile Fixes

  • SPE 8000-12000 ES — register map corrected (#212): The SPE profile previously inherited the SPF register map wholesale. Cross-analysis of the Issue #212 daytime scan against actual entity values (from the accompanying XLSX file) revealed several incorrect mappings:
    • Registers 36/37 (ac_input_power) produce a 429 GW overflow on SPE — the value is a signed 32-bit grid power register that the coordinator interprets as unsigned. These registers have been removed from the profile until correct signed semantics are confirmed.
    • Registers 64/65 (SPF: "AC discharge energy today") are grid import energy today on SPE. Confirmed: 20.0 kWh scan value vs 19.8 kWh actual ✓
    • Registers 66/67 (SPF: "AC discharge energy total") are grid import energy total on SPE. Confirmed: 855.2 kWh ✓
    • Registers 85/86 (SPF: "operational discharge energy today") are load energy today on SPE. Confirmed: 21.3 kWh vs 20.9 kWh actual ✓
    • Registers 87/88 (SPF: "operational discharge energy total") are load energy total on SPE. Confirmed: 1028.3 kWh vs 1027.9 kWh actual ✓
    • Registers 92–97 (generator discharge/power/voltage) removed — SPE has no generator input. All confirmed registers (battery voltage 50.12 V, grid voltage 235.8 V, PV1/PV2 voltage/power, temperatures, fan speeds, charge/discharge energy totals) remain correctly inherited from SPF.

Auto-Detection Fixes

  • SPA auto-detection (#249): SPA responds to all register ranges with zeros rather than exceptions, causing it to fall through into the MIN detection branch. Detection now checks register 1013 (battery voltage, always ~530 raw = 53 V on SPA) combined with register 38 (AC voltage in base range, always 0 on SPA). This check runs before the MIN series check. SPH-TL3 is not affected — it always has register 38 > 0 (grid voltage present even at night). SPH 3-6kW is not affected — its battery voltage is at register 13, not 1013.

  • MIC misclassification of legacy string inverters fixed (#242): Inverters using the legacy 0-124 register range but lacking the 3000+ range were incorrectly detected as MIC micro inverters if their PV voltage happened to be non-zero at register 3. MIC micro inverters operate at low panel voltages (< 80 V raw). The detection now checks: if reg 3 raw > 800 (> 80 V) and the 3000+ range is absent, the device is a legacy string inverter, not a MIC. It falls back to min_7000_10000_tl_x as the closest approximation and logs a warning. A dedicated legacy profile for this firmware class (DM1.0, ~11 kW, 3 strings, 0-124 range only) is planned pending further scan data and model confirmation.


v0.7.0

Issues: #174 · #131 · #212 · #225 · #240 · #243 · #244 · #247


Fixes

  • SPH TL3 — Energy Today drop at sunset fixed (#225): Per-MPPT energy registers (pv1/2/3_energy_today) are now used whenever any string has accumulated energy today, regardless of whether PV voltage/power is currently non-zero. Previously the data source switched to register 54 (AC output total, which includes battery discharge) at the moment PV production stopped, causing a visible drop of ~2 kWh at end of day. The per-MPPT sum is now held through the night and cleared at dawn when the inverter resets its registers.

  • WIT 8K-HU — Battery voltage wrong value fixed (#247): VPP register 31214 (battery_voltage_vpp, mapped to battery_voltage) reports a spuriously low value (e.g. 5.2 V) on some WIT firmware variants while the native register 8034 carries the correct reading (53.7 V). The integration now applies the same multi-candidate selection strategy already used for battery current: all available voltage registers are read, values outside the plausible range (10–800 V) are discarded, and the highest remaining candidate is selected. This resolves the secondary symptom too — battery power scale auto-detection was failing because V×I ≈ 1 W never exceeded the 50 W threshold.

  • SPF — Battery Power always zero fixed (#174): The _validate_spf_battery_power_sign function referenced data.inverter_status, which does not exist as a GrowattData field. The correct field is data.status. The AttributeError was silently caught by the battery data exception handler, leaving battery_power permanently at 0W.

  • SPH Hybrid — Load First Battery Minimum SOC display bugfix (#244): Corrected reading and display of the Load First SOC value introduced in v0.6.8.

New Sensors & Profile Updates

  • MID Series — Grid, load energy and battery sensors (#240): The MID profile was missing a large block of registers that the hardware responds to. Now available on both legacy and V2.01 variants:

    • Grid power flow: power_to_grid, power_to_user, power_to_load (regs 3041–3046)
    • Grid energy counters: energy_to_grid_today/total, energy_to_user_today/total (regs 3067–3074)
    • Load energy counters: load_energy_today, load_energy_total (regs 3075–3078)
    • grid_energy_today now reads directly from register 3071/3072 instead of a calculation that collapsed to zero when load energy was unavailable
    • V2.01 profile gains full battery support (31200+ VPP range, confirmed responding): voltage (31214, 404.8 V confirmed), SOC (31217), current (31215/31216), temperature (31222/31223), SOH (31218), power (31200/31201), charge/discharge energy (31202–31209)
    • has_battery is now True for mid_15000_25000tl3_x_v201
  • SPH / TL-XH — Accurate lifetime PV generation (#243): Registers 91/92 (Epv_total H/L, Growatt V1.39 protocol) added to SPH and TL-XH profiles. This is the raw DC-side cumulative generation shown in ShinePhone as "Total Power Generation" and is more reliable for the HA energy dashboard than energy_total (regs 55/56), which is a net calculated value that can drift with battery cycling. MOD, WIT, and SPH-TL3 already had these registers; MIC and SPF use 91/92 for other purposes and are unchanged.

  • SPH — Export Limit Registers Added (#131): Holding registers 122 (export_limit_mode, 0=Disabled/1=RS485) and 123 (export_limit_power, ×0.1 %) were missing from SPH 3-6kW and 7-10kW profiles. Now defined in both base profiles and inherited by all V2.01 variants.

  • SPE auto-detection fixed (#212): DTC code 64541 is now mapped to spe_8000_12000_es. Previously the integration fell through to SPH 7-10kW on first setup.


v0.6.8

Issues: #226 · #228 · #234 · #238


Changes at a Glance

  • MOD GEN4 — TOU reversion root cause fixed: Register 3049 ("Allow Grid Charge") was missing from the integration. On GEN4 hardware this register is a prerequisite gate — without it enabled, the firmware silently discards TOU writes after each cloud sync cycle. A new "Allow Grid Charge" select entity is now exposed under the Battery device.
  • MOD GEN4 — TOU enable/priority atomic write fix (#234): GrowattModTouEnable and GrowattModTouPriority previously wrote only the start register (single-register FC06 write). Both selects now write [start, end] atomically in one FC16 transaction — matching GrowattModTouTime and the Solax Modbus Growatt plugin. This should resolve enable/priority reversion; if it still occurs the ShineWiFi dongle is the likely cause.
  • MOD GEN4 — Duplicate "Allow Grid Charge" entity fixed (#234): The entity was being registered twice (generic loop + dedicated class), causing HA to silently discard the correct battery-device-assigned instance. Fixed with a skip guard in the generic loop.
  • MOD GEN4 — TOU slots 5–9 added: GEN4 hardware supports 9 time slots (registers 3038–3059, gap at 3046–3049 for EMS controls). Slots 5–9 now fully supported.
  • MOD GEN4 — TOU time entities now correct in automations (#234): GrowattModTouTime now sets _attr_has_entity_name = True (consistent with all other entity classes), ensuring TOU Period Start/End time pickers appear correctly under the Battery device in HA's automation action picker alongside the Enable and Priority selects.
  • MOD GEN4 — Atomic FC16 writes for TOU time: Start and end registers written together in one Modbus FC16 transaction, eliminating the partial-update window.
  • SPH GEN3 — Extended time periods: Battery First extended slots 4–6 (registers 1017–1025) and Grid First extended slots 4–9 (registers 1026–1034 and 1080–1088) now exposed as time picker and enable select entities (#131).
  • SPH GEN3 — AC Charge period naming fixed (#131): The three original time period entities (registers 1100–1108) now display as "AC Charge Time Period 1–3" rather than the ambiguous "Time Period 1–3", making it clear they are distinct from the Battery First and Grid First extended slots. Entity IDs are unchanged.
  • SPH GEN3 — Grid First periods 1–3 intentionally absent (#131): The SPH GEN3 register map does not expose separate Grid First slots 1–3. The AC Charge periods (1100–1108) are a separate scheduling feature. If Grid First 4+ values revert immediately, check whether the ShineWiFi dongle is connected and overriding local writes.
  • SPH Hybrid — Load First Battery Minimum SOC control (#238): New slider entity for SPH 3-6kW and 7-10kW (and their V2.01 variants) setting the minimum SOC the inverter will discharge to in Load First mode. Register 608, range 10–100 %, under the Battery device.
  • MOD — Grid Power fallback for zero 3000-range reads (#228): When registers 3043/3044 (power_to_grid) return 0, the coordinator now falls back to VPP meter registers 31112/31113 for the correct signed grid power value.
  • WIT — Battery current largest-absolute-value selection (#226): The previous cascade accepted the first non-zero reading from VPP register 31215. Some WIT firmware returns a small but incorrect non-zero on 31215 (e.g. −0.1 A when the actual current is +11.3 A). The coordinator now reads all available registers (31215, 8035, 3170) and picks the one with the largest absolute value within a ±300 A sanity bound.
  • New control guide: docs/CONTROLS.md with per-model instructions, SVG diagrams, and automation examples for MOD, SPH, WIT, and SPF.

⚠️ Upgrading from v0.6.6 — Entity ID Changes (#231)

If you are upgrading from v0.6.6, all entity IDs changed in v0.6.7. This also affects upgrades from v0.6.6 to v0.6.8.

v0.6.6 introduced sub-devices (Solar, Grid, Load, Battery) but left the integration prefix in entity names, causing HA to generate IDs with a double prefix — for example sensor.growatt_modbus_grid_growatt_modbus_energy_to_grid_today.

v0.6.7 corrected this. Entity IDs are now short and clean — e.g. sensor.growatt_modbus_grid_energy_to_grid_today. The entity registry and statistics history are migrated automatically, but the Energy Dashboard, automations, Lovelace cards, and any other configuration that references entity IDs by string must be updated manually.

See the full migration guide in the v0.6.7 release notes below for the complete before/after ID table and details.


MOD GEN4 — TOU setup guide

For each TOU period you want active:

  1. Enable Allow Grid Charge (Battery device, one-time prerequisite for GEN4)
  2. Set TOU Period N Start and TOU Period N End (time picker entities)
  3. Set TOU Period N PriorityLoad Priority, Battery Priority, or Grid Priority
  4. Set TOU Period N EnableEnabled

Slots 1–4 use registers 3038–3045. Slots 5–9 use registers 3050–3059. Registers 3046–3049 are EMS controls — the gap between slot 4 and slot 5 is intentional. If values still revert after enabling Allow Grid Charge, the ShineWiFi dongle cloud sync may be overriding local writes — disable cloud sync in the dongle's web UI or the Growatt app.

SPH GEN3 — Extended time period guide

Set the global Priority Mode (register 1044) to Battery First or Grid First, then configure individual windows using the time picker and enable entities for each slot group. Grid First slots 1–3 are not exposed separately — the AC Charge Time Period slots (1100–1108) are a distinct feature for scheduling AC charging, not Grid First priority windows.


New and Updated Entities

MOD GEN4 (TL3-XH profile only):

Entity Type Register New?
Allow Grid Charge Select 3049 New
TOU Period 5 Start / End Time 3050, 3051 New
TOU Period 5 Priority Select 3050 (bits) New
TOU Period 5 Enable Select 3050 (bit 15) New
TOU Period 6–9 (×4) Time + Select ×2 3052–3059 New

SPH GEN3 (3000–10000 TL profiles):

Entity group Type Registers New?
Batt First Period 4–6 Start/End Time (×6) 1017–1025 New
Batt First Period 4–6 Enable Select (×3) 1019, 1022, 1025 New
Grid First Period 4–6 Start/End Time (×6) 1026–1034 New
Grid First Period 4–6 Enable Select (×3) 1028, 1031, 1034 New
Grid First Period 7–9 Start/End Time (×6) 1080–1088 New
Grid First Period 7–9 Enable Select (×3) 1082, 1085, 1088 New

🔧 Fix — MOD: Grid Power Shows 0 or Wrong Direction (#228)

On MOD inverters (e.g. mod_6000_15000tl3_x), the 3000-range registers 3043/3044 (power_to_grid_high/low) return 0 on some firmware builds even when the inverter is actively importing or exporting. Because power_to_grid was 0, the grid_power sensor fell through to the fallback calculation (solar + discharge) − (load + charge), which can produce an incorrect or opposite-sign result.

The VPP registers 31112/31113 (meter_power) carry the correct signed 32-bit value for the same measurement (positive = export, negative = import). In the confirmed scan: 3044 = 0 while 31113 decoded to −9,601.8 W (importing).

Fix:

  • profiles/mod.py: maps_to='power_to_grid_low' added to register 31113 so it is found by the fallback lookup.
  • growatt_modbus.py: When the primary power_to_grid_low (3044) reads 0, the coordinator now tries meter_power_low (31113 via _find_register_by_name_with_fallback) before accepting 0 W. Non-zero VPP value is used and logged at DEBUG.

🔧 Fix — WIT: Battery Current Shows 0 When VPP Register 31215 Returns 0 (#226)

Some WIT firmware variants do not implement Ibat in the VPP cluster register 31215 — it returns 0 permanently while the battery is actively charging or discharging. Because VPP was the preferred range (voltage and SOC via VPP were correct), the coordinator selected 31215, read 0, and never tried the native 8000-range register 8035 (which held the correct signed value, e.g. raw 65477 = −5.9 A charging).

Fix:

  • growatt_modbus.py: Battery current now cascades — VPP (31215) → native 8035 → 3000-range 3170 — before accepting 0 A. A non-zero value at any fallback stage short-circuits the chain and is logged at DEBUG.
  • profiles/wit.py: Registers 3169/3170/3171 added as internal fallback sources (battery_voltage_3k, battery_current_3k, battery_soc_3k). These are not exposed as HA sensors.

Files Changed

File Change
profiles/mod.py Added registers 3049 and 3050–3059 to MOD_6000_15000TL3_XH holding_registers;maps_to='power_to_grid_low' on register 31113
profiles/sph.py Added registers 1017–1034 and 1080–1088 to SPH_3000_6000 and SPH_7000_10000
profiles/wit.py Added registers 3169–3171 as internal battery fallback sources
const.py Extended MOD_TOU_PERIODS to 9 entries; added allow_grid_charge and SPH extended periods to WRITABLE_REGISTERS
growatt_modbus.py Added GrowattData fields and coordinator reads for all new registers; power_to_grid VPP fallback; battery_current cascade
select.py Added GrowattModAllowGridChargeSelect class
time.py Replaced dual single-register writes with atomic FC16 pair writes for GrowattModTouTime
docs/CONTROLS.md New comprehensive control guide covering all model families
docs/images/ New SVG diagrams: tou-register-map, mod-tou-setup-flow, sph-time-periods, control-model-comparison

v0.6.7

Issues: #231 · #226 · #228

⚠️ BREAKING CHANGE (upgrading from v0.6.6): All entity IDs changed in this release. The integration migrates them automatically on first load, but automations, scripts, and dashboards that reference entity IDs by string must be updated manually. See the full details in the migration guide section below.

Changes at a Glance

  • Entity ID regression fixed (#231): v0.6.6's sub-device change caused entity IDs to grow a double prefix (e.g., sensor.growatt_modbus_grid_growatt_modbus_energy_to_grid_today). IDs are now correct and short. All existing entity IDs are automatically migrated on first load, but automations/dashboards using the old bugged IDs will need updating.
  • WIT battery current no longer drops to 0 A when the 8000-range block read fails intermittently (#226) — critical registers are now retried individually after a failed block read.
  • MOD HU (MOD 12-KTL3-HU, MOD TL3-XH) improvements (#228):
    • pv1_energy_today, pv2_energy_today, and pv_energy_total sensors now work (registers were missing from MOD profile)
    • charge_stopped_soc, discharge_stopped_soc, charge_power_rate, and ac_charge_enable controls added to MOD profile
    • Battery power now sourced from VPP range (31200/31201) — more reliable than the intermittent 3000-range charge/discharge registers
    • DTC code 5401 (MOD 12-KTL3-HU) added to auto-detection — fresh installs now select the correct Hybrid profile automatically

⚠️ BREAKING CHANGE — Entity IDs Changed for All Entities (#231)

This release changes entity IDs for all sensors, controls, and binary sensors.

Background

v0.6.6 introduced sub-devices (Solar, Grid, Load, Battery) so entities could be logically grouped in the Home Assistant device list. When an entity belongs to a sub-device, HA generates its entity ID by combining the sub-device slug with the entity name slug. This was unintentional at the time: because entity _attr_name still included the integration prefix ("Growatt Modbus …"), HA created IDs with a double prefix — for example:

sensor.growatt_modbus_grid_growatt_modbus_energy_to_grid_today
                         ↑ sub-device slug   ↑ entity name slug (still had prefix)

What the fix does

Entity classes now set has_entity_name = True and use only the short name (e.g., "Energy to Grid Today"). HA then composes:

{domain}.{device_slug}_{short_name_slug}
sensor.growatt_modbus_grid_energy_to_grid_today

Automatic migration

The integration migrates all existing entity IDs on first load using the entity registry (unique_id is the stable anchor — the entity's internal identity never changes, only its ID string). You will see log entries like:

v0.6.7 entity ID migration: sensor.growatt_modbus_grid_growatt_modbus_energy_to_grid_today → sensor.growatt_modbus_grid_energy_to_grid_today

What you need to do

The entity registry migration is automatic — the integration's entities will appear under their new IDs immediately, and long-term statistics history is preserved (HA keys statistics to the stable unique_id, not the entity ID string).

However, the following do NOT update automatically and must be reconfigured manually:

  • Energy Dashboard — HA stores the Energy Dashboard configuration as hardcoded entity ID strings in .storage/energy. You must re-open Settings → Energy and re-select each sensor (grid import/export, solar production, battery charge/discharge, etc.) using the new IDs.
  • Automations or scripts that reference entity IDs by string (not the entity picker)
  • Lovelace dashboard cards that hardcode entity IDs rather than using the entity picker
  • External integrations or Node-RED flows using the old IDs

New entity ID pattern (examples)

Entity Old ID (v0.6.6 bugged) New ID (v0.6.7)
Energy to Grid Today sensor.growatt_modbus_grid_growatt_modbus_energy_to_grid_today sensor.growatt_modbus_grid_energy_to_grid_today
Battery SoC sensor.growatt_modbus_battery_growatt_modbus_battery_soc sensor.growatt_modbus_battery_battery_soc
PV Energy Today sensor.growatt_modbus_solar_growatt_modbus_energy_today sensor.growatt_modbus_solar_energy_today
House Consumption sensor.growatt_modbus_load_growatt_modbus_house_consumption sensor.growatt_modbus_load_house_consumption
Inverter Status sensor.growatt_modbus_growatt_modbus_inverter_status sensor.growatt_modbus_inverter_status

Note: If your integration name is not "Growatt Modbus" (e.g., you renamed it during setup), substitute your actual device name slug in the examples above.


🔧 Fix — WIT Battery Current Drops to 0 A on Intermittent Block Read Failure (#226)

WIT inverters read battery registers from the 8000–8999 range in a single block. If that block read fails (intermittent RS485/TCP instability), all 8000-range registers are absent from the cache for that cycle. battery_current (register 8035) resolves to None or 0.0 = 0.0, so the entity shows 0 A — even when the battery is actively charging or discharging.

Fix (growatt_modbus.py): After any failed 8000-range block read, the five most critical registers (8034 battery voltage, 8035 battery current, 8093–8095 battery SoC / charge state) are retried individually. If a single-register read succeeds, that value is placed in the cache and used for the cycle. A warning log is emitted on block failure; per-register retry results are logged at DEBUG level.


🔧 Fix — MOD HU: PV String Energy Sensors Always 0 (#228)

pv1_energy_today, pv2_energy_today, and pv_energy_total were absent from the MOD TL3-XH hybrid profile. The corresponding registers (59/60, 63/64, 91/92) are in the base 0–124 scan range and respond correctly on MOD HU hardware (confirmed: 9.2 kWh, 10.4 kWh, 3445 kWh).

Fix (profiles/mod.py): Registers 59/60, 63/64, and 91/92 added to MOD_6000_15000TL3_XH input_registers.


🔧 Fix — MOD HU: Battery Power Intermittently Shows 0 (#228)

The 3000-range charge/discharge registers (3178–3181) used as the primary battery power source on MOD HU are unreliable — they intermittently return 0 during the same poll cycle in which battery_power at VPP registers 31200/31201 shows the correct value (+1130 W charging in scan #228-2).

Fix (profiles/mod.py): Registers 31200/31201 renamed from battery_power_vpp_high/low to battery_power_high/low. With the _vpp suffix removed, the coordinator's standard fallback chain finds these registers as the primary signed battery power source. Charge/discharge power entities are then derived from the sign of battery_power — positive = charging, negative = discharging — consistent with the standard convention used by all other profiles.


New — MOD HU: Charge/Discharge SOC Controls (#228)

The following controls now appear on MOD Hybrid installs. All four holding registers were confirmed responding in scan #228:

Control Register Description
Discharge Stopped SoC 1071 Minimum SoC before battery stops discharging
Charge Power Rate 1090 Battery charge power rate limit (0–100%)
Charge Stopped SoC 1091 SoC level at which battery stops charging
AC Charge Enable 1092 Allow charging from the grid (AC source)

New — Auto-Detection: DTC Code 5401 (#228)

DTC code 5401 (reported by MOD 12-KTL3-HU hardware) was not in the detection map. Fresh installs fell back to heuristic detection and selected the grid-tied MOD profile instead of the Hybrid profile.

Fix (auto_detection.py): DTC 5401 now maps to mod_6000_15000tl3_xh_v201 (same as DTC 5400).


v0.6.6

Issues: #203 · #204 · #18 · #131 · #206 · #212 · #214 · #224 · #226

Summary

  • Energy sensors no longer show 0 or corrupt totals when the inverter is offline or sleeping at night — energy totals are now persisted across HA restarts
  • WIT battery current fixed (had shown 0 since ~v0.5.4)
  • MIN TL-XH startup Modbus warning spam and via_device error eliminated
  • Control entities (control_authority, VPP export limit) now gated on live hardware probe — no longer appear on hardware that doesn't support them
  • WIT: disabling control authority no longer silently resets export limit mode
  • TL-XH / MOD / WIT serial_number sensor entity now shows correct VPP serial from registers 3001–3005 (was showing garbled data from legacy registers)
  • SPE 8000-12000 ES profile added
  • Write verification with automatic retry on all control writes; cloud override detection with persistent HA notification
  • MOD TL3-XH TOU schedule controls (4 time periods)
  • SPF battery power and energy sensors fixed (were showing 0 due to voltage guard and offline classification issues)
  • Universal Register Scanner: VPP control ranges and MOD holding ranges added

🔧 Fix — Energy Sensors Show 0 at Night / After HA Restart (Issues #206, re-fix)

Two further root causes found after the v0.6.6b2 fix for issue #206:

  1. Empty register response not treated as failure (growatt_modbus.py): When the RS485-to-TCP adapter is online but the inverter is sleeping, some adapters return a valid TCP frame with an empty register list. This passed the non-None check, set _inverter_online = True, and all sensor values defaulted to 0.0. Empty and short-count responses are now rejected as read failures, correctly triggering offline behaviour.
  2. Energy retention not persisted across HA restarts (coordinator.py): _retained_lifetime_totals and _retained_daily_totals were in-memory dicts, cleared on every restart. After a nighttime HA restart, there was no retained baseline to compare against when the dormant inverter returned zeros. These dicts are now persisted to HA storage (.storage/growatt_modbus.<entry_id>_energy_totals) — lifetime totals always restored; daily totals restored only if saved on the same calendar day.
  3. Wrong field names in debounce reset (coordinator.py): The wakeup debounce was assigning to data.battery_charge_today / data.battery_discharge_today (non-existent fields). Corrected to charge_energy_today / discharge_energy_today.
  4. Battery energy fields missing from midnight reset (coordinator.py): Both midnight reset paths now zero charge_energy_today, discharge_energy_today, ac_charge_energy_today, ac_discharge_energy_today, op_discharge_energy_today.

🔧 Fix — Energy Totals Dropping to Zero on Dormant/Offline Inverters (Issue #206)

total_increasing energy sensors returned 0 when the inverter was dormant at night or truly offline, causing phantom counter resets in the HA Energy Dashboard.

Two root causes:

  1. Dormant inverter: Stays powered (battery/grid) and responds to Modbus but returns 0 for all production registers. Connection succeeds → _inverter_online = True → sensors report zeros.
  2. Truly offline inverter: Coordinator returned cached data with last_update_success = True → entities stayed "available" → HA recorded stale flatlines as real data.

Fix:

  • available = False when offline: Sensor entities check coordinator.is_online. All entities go unavailable when the inverter stops responding — statistics engine ignores unavailable states.
  • Dormant-inverter retention: _protect_energy_totals() tracks last known non-zero values. When hardware reports 0 but a non-zero was previously seen, the retained value is substituted. Daily retention clears at midnight.

🔧 Fix — WIT Battery Current Always Shows 0 (Issue #226)

WIT's battery_current register is at address 8035 (8000–8124 range). Battery range detection only scored VPP (≥31000) and fallback (1000–3999) addresses — 8035 was never scored, range resolved as 'vpp', filter addr >= 31000 excluded register 8035 → battery_current = 0.

Fix (growatt_modbus.py): 8000–8999 addresses now count as VPP-tier in _detect_battery_register_range(). _find_register_by_name_with_fallback() also checks the 8000-range as a secondary fallback when the primary range filter returns empty. This also restores battery power scale auto-detection which requires battery_current != 0.

The 20% power overestimation noted in the same issue is not yet addressed — register scan data needed to confirm root cause.


🔧 Fix — MIN TL-XH: Startup Warning Spam + via_device Error (Issue #224)

A) Startup Modbus warnings: MIN TL-XH receives ExceptionResponse(exception_code=1) for optional VPP registers (31000+) that don't exist on its firmware. These were already suppressed after the first attempt via _failed_optional_ranges, but the first-attempt log was at WARNING level. A new log_errors parameter on read_input_registers() downgrades first-attempt errors to DEBUG for optional register ranges.

B) via_device race condition (HA 2025.12+): Sub-devices reference via_device = (DOMAIN, f"{entry_id}_inverter"). The parent device could be missing from the registry when sub-device sensors registered, causing "referencing a non-existing via_device" errors. Fixed by explicitly pre-creating the parent inverter device in __init__.py using device_registry.async_get_or_create() before async_forward_entry_setups().


🔧 Fix — Control Authority Selector Shown on Unsupported Hardware (Issue #224)

control_authority (register 30100) appeared as a select entity on MIN TL-XH, MIN TL-X, and other profiles where the hardware does not implement the VPP 2.01 control register range. Any write silently failed with Illegal Function.

Fix: The entity is now gated on a live hardware probe — same pattern as vpp_export_limit_enable. A vpp_control_authority_available flag is set only when register 30100 returns a valid response at startup. If unresponsive, the entity is not created and any pre-existing stale entity is removed from the entity registry on reload.


🔧 Fix — TL-XH / MOD / WIT Serial Number Entity Shows Incorrect Value

The serial_number sensor entity on VPP-range models read from holding registers 9–13 (legacy base range), which on VPP firmware does not contain the serial number — producing garbled output (e.g. "AL1.0ZAba").

VPP-range models store the serial number in holding registers 3001–3005 (10 ASCII chars, one pair per register). After the legacy read, affected profiles now attempt a second read of that range. If the result is a valid Growatt-format serial (≥4 chars, first two letters), it overrides; otherwise the legacy value is kept as fallback.

Models affected: All profiles with TL_XH, MOD_, or WIT_ in the register map name. Note: the HA Devices & Services serial was already correct via the coordinator's separate read path — only the sensor entity was wrong.


🔧 Fix — WIT: Disabling Control Authority Resets Export Limit Mode (Issue #203)

Disabling control_authority (register 30100 = 0) transiently resets register 122 (export_limit_mode) to 0 as a WIT hardware side-effect. Older firmware does not auto-restore the value, silently clearing the export limit configuration.

Fix (select.py, coordinator.py): Register 122 is read and saved before writing control_authority = Disabled. When control_authority = Enabled is written and verified, the saved value is restored after a 300ms delay. WIT profiles only.


✨ New — SPE 8000-12000 ES Profile (Issue #212)

Added support for the SPE 8000-12000 ES single-phase hybrid inverter. Register scan analysis confirmed it uses the same Modbus register protocol as SPF (registers 0–97), despite being grid-tied with peak shaving capability. Features: dual MPPT, battery storage, peak shaving, parallel operation (up to 108kW), dual outputs.

Auto-detection via model name patterns (SPE8000, SPE10000, SPE12000). Manual selection available as "SPE (8-12kW)".


✨ New — Write Verification & Cloud Override Detection (Issue #214)

All control writes now include read-back verification with up to 3 retries. If a verified write is later found to have reverted on the next poll cycle (e.g. overwritten by ShineWiFi dongle), a persistent notification appears in HA explaining the issue. A setup warning is also shown when configuring a battery-enabled inverter with a cloud dongle detected.


🔧 Fix — Stale Time Period number Entities After Upgrade (Issue #214)

After upgrading from pre-v0.6.4, old number platform time_period_*_start/end entities remained alongside the new time platform entities. Entity registry migration in __init__.py removes the stale entities automatically on HA restart.


🔧 Fix — VPP Export Limit Controls Appear on Non-VPP Inverters

MIN TL-X and other non-VPP inverters showed VPP Export Limit Enable and VPP Export Limit Power Rate controls even though the hardware does not support registers 30200–30201.

Fix: Entity creation is gated on a vpp_export_limit_available flag set only when those registers respond. Stale entities are removed on reload.


✨ New — MOD TL3-XH TOU Schedule Controls (Issue #131)

MOD Hybrid users can now set Time-of-Use schedule periods from Home Assistant: 4 × time period start (HH:MM), 4 × end, 4 × priority (Load/Battery/Grid), 4 × enable. Uses holding registers 3038–3045 with bit-packed encoding (bit15=enable, bit13-14=priority, bit8-12=hour, bit0-7=minute).


🔧 Fix — SPF Battery Power and Energy Sensors Showing Zero (Issues #204, #18)

Three root causes fixed:

  1. Offline behaviour classification: battery_charge_total, battery_discharge_total, ac_charge_energy_total, and related sensors were not correctly classified in SENSOR_TYPES, causing them to drop to 0 when offline instead of going unavailable.
  2. AC input / load power offline behaviour: ac_input_power, ac_apparent_power, and load_power were not classified as power sensors, causing them to go unavailable when they should hold 0 while offline.
  3. Battery power zeroed at SOC > 0: The 10V voltage guard (to prevent garbage readings from a disconnected battery) also blocked power readings from connected batteries reporting 0V in bypass/standby. The guard now requires both voltage < 10V and SOC < 5% before zeroing battery power.

✨ New — Universal Scanner: VPP Control Ranges + MOD Holding Ranges

Scanner now covers VPP control holding registers (30100–30499, individually enabled via scan_vpp_control) and MOD TL3-XH FC04 holding ranges including TOU registers 3038–3045 (scan_mod_extended).


v0.6.4

  • #204 · #214

🔧 Fix — Time Period Controls Show HH:MM Time Picker Instead of Raw Numbers (Issue #214)

SPH inverter users with time period controls (e.g., SPH 3600) reported the start/end time displays showing values like 1.536 and 5.632 instead of readable times. These correspond to 06:00 and 22:00. Any attempted writes were sending incorrect values to the inverter hardware.

Root cause: The inverter stores time in a hex-packed byte formathours × 256 + minutes — not the HHMM decimal format the code assumed. 06:00 encodes as 0x0600 = 1536 and 22:00 as 0x1600 = 5632. The previous NumberEntity implementation displayed the raw integer directly (showing 1536) and wrote user-entered values without conversion (writing 600 for "06:00" produced 0x0258 = 02h 88m — invalid time).

Fix:

  • Replaced the 6 time period start/end NumberEntity controls with a new TimeEntity platform (time.py)
  • TimeEntity provides a native HH:MM time picker in the Home Assistant UI
  • Decode: raw → (hours = raw >> 8, minutes = raw & 0xFF) → datetime.time(hours, minutes)
  • Encode: datetime.time(h, m) → (h << 8) | m → register write
  • Added Platform.TIME to __init__.py platform list
  • Number entities no longer created for time_period_*_start/end controls (to avoid duplicates)

Impact: Time period enable controls (time_period_*_enable) are unchanged — they remain Select entities (Enabled/Disabled).


🔧 Fix — SPF 5000/6000 ES Battery Entities Showing Zero Since v0.6.0 (Issue #204)

SPF 5000 ES and SPF 6000 ES Plus users reported all battery entities (voltage, SOC, power, temperature) showing 0 after upgrading from v0.5.9. Direct register reads confirmed the data was present — e.g., register 18 returned 48.73V — but the HA entity showed 0.0V.

Root cause: Commit e26a870 (v0.6.0) introduced _detect_battery_register_range() to resolve an ambiguity in models that expose battery data at both VPP (31000+) and fallback (1000–3999) addresses. The scoring logic awards points only for addresses in those two ranges. SPF uses the legacy base range (registers 0–97), so neither score incremented — both stayed 0 — and the code defaulted to 'fallback'. The subsequent _find_register_by_name_with_fallback() then filtered for 1000 ≤ addr < 4000, which excluded SPF's register 17 (battery_voltage), returning None. All battery values silently fell back to 0.

Fix: Added 'legacy' range handling to both methods in growatt_modbus.py. When offgrid_protocol=True (set in all SPF profiles), _detect_battery_register_range() immediately returns 'legacy' without running the scoring loop. _find_register_by_name_with_fallback() then accepts any address below 1000 for 'legacy' range — matching SPF's register space correctly.


v0.6.3

  • #174 · #207 · #209 · #210 · #211

🔧 Fix — SPH TL3 Energy Today Missing PV3 String (Issue #211)

SPH TL3 10000 (and other 3-MPPT models) showed Energy Today roughly 1/3 lower than expected after the v0.5.0 upgrade.

Root cause: The v0.5.0 fix for Issue #172 changed energy_today to use per-MPPT DC energy registers (pv1+pv2) instead of AC output register 53-54. However, the profile and coordinator never included PV string 3 (registers 67-68, Epv3_today) in the sum — so on 3-string inverters the PV3 contribution was silently dropped.

Fix:

  • Added pv3_energy_today_high/low (registers 67-68) to profiles/sph_tl3.py
  • Added pv3_energy_today field to GrowattData dataclass
  • Coordinator now reads PV3 energy and includes it in the energy_today sum when PV3 is connected

Impact: 2-string models are unaffected (pv3_connected = False gates the addition).


🔧 Fix — SPH TL3 Grid Import Energy Mirrors Export (Issues #209, #211)

SPH TL3 users with Invert Grid Power enabled reported that Grid Import Energy Today showed the same values as grid export energy — effectively mirroring it.

Root cause: The v0.5.1 fix for Issue #183 introduced a code path where, when invert_grid_power=True and a hardware energy register is available, the code reads from energy_to_grid_today (export) instead of energy_to_user_today (import). This was based on the assumption that CT clamp orientation also swaps the hardware energy accumulators.

Why the assumption is wrong: SPH TL3's energy registers (1044-1051) are accumulated by the inverter's internal bidirectional power meter, independent of CT clamp direction. energy_to_user_today always correctly measures grid import regardless of CT orientation — only real-time power registers need CT inversion.

Fix: Removed the CT-orientation swap for hardware energy registers in sensor.py. When hardware import registers are available, they are always used directly. The invert_grid_power flag continues to apply correctly to all real-time power sensors.


🔧 Fix — SPH 3-6kW and 7-10kW V2.01 Missing Power Flow Registers (Issue #207)

SPH 3600 (and all SPH 3-10kW V2.01 protocol models) showed incorrect grid import/export direction and Power to User / Power to Load always 0.

Root cause: The SPH_3000_6000_V201 and SPH_7000_10000_V201 profiles were missing the storage-range power flow registers (1015-1038) and grid import energy registers (1044-1047). Without them, power_to_user, power_to_grid, and power_to_load stayed at 0, causing the fallback calculation (solar + discharge) − (load + charge) to produce wrong grid direction signs.

Fix: Added the following registers to both V201 profiles in profiles/sph.py, per Growatt Modbus RTU V1.20 protocol:

Register Name Description
1021-1022 power_to_user AC power to user total (grid import power)
1029-1030 power_to_grid AC power to grid total (signed: positive=export)
1037-1038 power_to_load INV power to local load total
1044-1045 energy_to_user_today Grid import energy today
1046-1047 energy_to_user_total Grid import energy total

🔧 Fix — SPF Battery Power Sign Correction During PV Charging (Issue #174)

SPF 6000 ES Plus intermittently showed battery as discharging when it was actually charging from solar (status=5, PV Charge).

Root cause: SPF hardware occasionally transmits a positive raw value for the battery power register during PV charging. After applying the required sign inversion (combined_scale=-0.1), the result becomes negative — misidentified as discharging. Battery current (register 68) cannot be used for validation as it only measures during AC charging.

Fix: Added _validate_spf_battery_power_sign() method in growatt_modbus.py. When offgrid_protocol=True, the inverter status code is checked after the hardware sign inversion. If the status indicates charging (codes 5-10) but battery power is negative, or discharging (code 2) but power is positive, the sign is corrected and a warning is logged. A 10W threshold prevents noise correction. Ambiguous status 12 (PV Charge+Discharge) is skipped.


🔧 Fix — SPH TL3 Missing Controls: AC Charge, Time Periods, Priority Mode (Issue #210)

SPH 10000TL3 BH-UP (and all SPH TL3 3-10kW models) were missing the AC Charge, Time Period, and Discharge/Charge Rate control entities in Home Assistant. Additionally, Priority Mode changes silently failed to write.

Root cause — two bugs in profiles/sph_tl3.py:

  1. Missing holding registers: The base profile only defined 3 holding registers (on_off, system_enable, priority). The integration creates control entities only for registers present in the profile, so 14 registers (1070–1071, 1090–1092, 1100–1108) were absent → no entities created.
  2. Wrong register name: Register 1044 was named priority instead of priority_mode. All control write paths resolve registers by name — SELECT_DEFINITIONS uses the key priority_mode, so no holding register was found at write time → silently dropped.

Fix: Replaced the holding_registers block in profiles/sph_tl3.py with the full 18-register set (matching SPH 7-10kW single-phase), adding the correct name and full metadata for each register. The SPH_TL3_3000_10000_V201 profile inherits these automatically via Python dict unpacking.

Controls now available for SPH TL3:

Register Entity Description
1044 Priority Mode Load First / Battery First / Grid First
1070 Discharge Power Rate % limit on battery discharge
1071 Discharge Stop SOC SOC% at which discharge halts
1090 Charge Power Rate % limit on battery charge
1091 Charge Stop SOC SOC% at which charge halts
1092 AC Charge Enable Enable/disable charging from grid
1100–1108 Time Periods 1–3 Start/end/enable for timed charge windows

v0.6.2

🔧 Fix — MIN TL-XH Battery Energy Totals Showing Zero (Issue #191)

Three battery energy sensors were always reporting 0 for MIN TL-XH 3000-10000 V2.01 inverters after the v0.6.1 upgrade.

Sensors affected: Battery Charge Total, Battery Discharge Total, AC Charge Energy Total

Root cause: The MIN_TL_XH_3000_10000_V201 profile defined battery energy today registers (3125–3130) but was missing the corresponding total registers. The coordinator searched for register names charge_energy_total_low, discharge_energy_total_low, and ac_charge_energy_total_low — none existed in the profile — and fell back to the GrowattData defaults of 0.0. Because hasattr() still returned True (the field exists in the dataclass), sensors appeared in HA but perpetually showed 0.

Fix: Added the missing registers to profiles/tl_xh.py, confirmed against real hardware scan:

Registers Sensor Confirmed Value
3127 / 3128 Battery Discharge Total 481.5 kWh
3131 / 3132 Battery Charge Total 528.9 kWh
3133 / 3134 AC Charge Energy Today ~0 kWh (grid→battery today)
3135 / 3136 AC Charge Energy Total 37.4 kWh (grid→battery lifetime)

The ac_charge_energy_total register (3135/3136) tracks exclusively grid→battery charging, matching the Growatt server "Batterieladung aus Stromnetz" lifetime value.


🔧 Fix — Energy Sensors Show Unavailable When Inverter is Offline (Issue #206)

Energy sensors (device class energy, state class total_increasing) previously retained their last value when the inverter went offline at night. When the inverter came back online in the morning, Home Assistant's energy statistics briefly saw the previous day's retained value followed by the new day's value, creating artificial spikes or outliers in the energy dashboard.

Fix: Energy sensors now report unavailable instead of retaining stale values when the inverter is offline. Home Assistant correctly handles unavailable periods in energy statistics — no data gap is recorded, and the dashboard picks up cleanly from the next valid reading.

Affected sensors: All energy sensors (energy today, energy total, grid import/export energy, battery charge/discharge energy, AC charge energy) across all inverter models.

Before: Inverter goes offline at 22:00 → sensors retain e.g. 12.5 kWh all night → inverter wakes at 06:00 showing 0.1 kWh → HA records a large negative spike to correct the total.

After: Inverter goes offline at 22:00 → sensors show unavailable → inverter wakes at 06:00 showing 0.1 kWh → HA records normally with no outlier.


🔧 Fix — Battery Power Garbage Values When Battery Disconnected (Issue #205)

On SPF off-grid inverters with a disconnected or fully depleted battery (voltage = 0V), the battery power registers contained garbage values that were being interpreted as valid signed 32-bit readings. This caused the battery power sensor to show absurd values (e.g. 101 MW) instead of 0W.

Root cause: With battery voltage at 0V, register 77 (battery_power_high) = 50000, register 78 (battery_power_low) = 0. Combined as signed 32-bit: −1,018,167,296. Scaled by −0.1: +101,816,729.6 W.

Fix: Added a voltage threshold check — if battery voltage is below 10V, battery power is forced to 0W regardless of register values. Affected models: SPF series and potentially other models with battery storage when the battery is physically absent.


🆕 MOD TL3-XH — Battery Sensors Added (Issue #131)

The MOD 10000TL3-XH (VPP V2.01, DTC 5400) profile now exposes complete battery monitoring from the 3125–3185 and 31218 register ranges. Previously these registers were either absent from the profile or incorrectly mapped (ac_charge_energy_total was misidentified as battery_bms_temp at register 3136, which would have shown 530.5°C).

New sensors for MOD TL3-XH:

Registers Sensor Scale Confirmed at Scan
3125 / 3126 Battery Discharge Today ×0.1 kWh 6.3 kWh
3127 / 3128 Battery Discharge Total ×0.1 kWh 1216.9 kWh
3129 / 3130 Battery Charge Today ×0.1 kWh 4.3 kWh
3131 / 3132 Battery Charge Total ×0.1 kWh 1389.0 kWh
3133 / 3134 AC Charge Energy Today ×0.1 kWh 4.0 kWh
3135 / 3136 AC Charge Energy Total ×0.1 kWh 530.5 kWh
3169 Battery Voltage ×0.01 V 72.83 V
3170 Battery Current ×0.1 A 0.0 A
3171 Battery SOC ×1 % 10% (confirmed at scan)
3175 / 3176 Battery Temp ×0.1 °C 45.4°C
3178 / 3179 Battery Discharge Power ×0.1 W 5.0 W
3180 / 3181 Battery Charge Power ×0.1 W 0.0 W
31218 Battery SOH ×1 % 100%

Register scan was conducted at night (SOC=10% confirmed), validating register 3171=10 as SOC and 31218=100 as State of Health.

Bug fix (same PR): Register 3136 was previously mapped as battery_bms_temp — a copy-paste error from a nearby temperature register. The raw value of 5305 × 0.1 = 530.5 kWh is clearly an energy value, not a temperature. Corrected to ac_charge_energy_total_low.

Battery control (MOD): Battery control holding registers have not yet been confirmed for MOD hardware. Register scan showed the SPH-style 1000–1124 range returns all zeros, and VPP control (30099=0) is not available. Control is deferred to a follow-up release pending hardware confirmation. See docs/CONTROL.md for details.


🎛️ Inverter Control — SPH, SPF, WIT

This release documents and validates the full control entity stack for SPH, SPF, and WIT inverter families. These controls were already implemented in the codebase; this release confirms their status, adds documentation, and ensures all are correctly exposed in Home Assistant.

Control is profile-gated: entities are only instantiated when the corresponding holding registers are present in the active profile. No controls appear for models without confirmed registers.

SPH Hybrid (3–10kW) — Persistent Writes

Entity Type Register Options / Range
Priority Mode Select 1044 Load First / Battery First / Grid First
AC Charge Enable Select 1092 Disabled / Enabled
Discharge Power Rate Number 1070 0–100 %
Discharge Stop SOC Number 1071 0–100 %
Charge Power Rate Number 1090 0–100 %
Charge Stop SOC Number 1091 0–100 %
Time Period 1–3 Start/End/Enable Number/Select 1100–1108 HHMM / Enabled-Disabled
System Enable Select 1008 Disabled / Enabled*(HU models only)*

SPF Off-Grid (3–6kW) — Persistent Writes

Entity Type Register Options / Range
Output Priority Select 1 SBU / SOL / UTI / SUB
Charge Priority Select 2 CSO / SNU / OSO
AC Input Mode Select 8 APL / UPS / GEN
Battery Type Select 39 AGM / Flooded / User / Lithium / User 2
AC Charge Current Number 38 0–80 A
Generator Charge Current Number 83 0–80 A
Battery→Utility SOC Number 37 0–100 % (Lithium)
Utility→Battery SOC Number 95 0–100 % (Lithium)

WIT Commercial Hybrid (4–15kW) — VPP Time-Limited Overrides

Entity Type Register Options / Range
Work Mode Select 202 Standby / Charge / Discharge
Active Power Rate Number 201 0–100 %
Export Limit (W) Number 203 0–20000 W
Control Authority Select 30100 Disabled / Enabled
VPP Export Limit Enable Select 30200 Disabled / Enabled
VPP Export Limit Rate Number 30201 −100–+100 %
Remote Power Control Select 30407 Disabled / Enabled
Remote Control Duration Number 30408 0–1440 min
Remote Charge/Discharge Power Number 30409 −100–+100 %

WIT commands are time-limited. The inverter reverts to its TOU schedule when the duration expires. See docs/WIT_CONTROL_GUIDE.md for the full VPP protocol explanation.

📖 Full control documentation →


Model and Sensor Availability Summary

Model Battery Sensors Battery Control Control Method Notes
SPH 3–6kW Yes Yes Persistent writes Registers 1044, 1070–1108
SPH 7–10kW Yes Yes Persistent writes Same register range as 3–6kW
SPH/SPM HU 8–10kW Yes + BMS Yes Persistent writes Adds BMS sensors, system_enable (1008)
SPF 3–6kW ES PLUS Yes (limited) Yes Persistent writes No battery temp; current only during AC charge
WIT 4–15kW Yes Yes (timed) VPP overrides Time-limited; base mode is read-only
MOD 10000TL3-XH Yes (new) No (pending) Control registers not yet confirmed
MIN TL-XH 3–10kW Yes (fixed) No No battery control registers
MIN 3–10kW No No Grid-tied, no battery
MIC 0.6–3.3kW No No Grid-tied micro inverter

v0.6.1

🔧 Critical Fix - MIN TL-XH Solar and Grid-Import Energy Calculations

This release fixes critical energy calculation issues for MIN TL-XH 3000-10000 V2.01 inverters that were introduced in v0.5.1.

What Was Fixed:

Problem 1: Grid Import Energy Showing Zero or Null

After upgrading from v0.4.9 to v0.5.1+, MIN TL-XH users reported:

  • Grid import energy became null/zero after update
  • Grid power visible but grid import energy was 0
  • Energy dashboard showed no grid import despite actually importing from grid

Root Cause: Version 0.5.1 (commit df333cb) fixed SPH-TL3 grid import energy by using hardware register energy_to_user_today/total. However, the code incorrectly assumed this register means "grid import" for ALL inverter models.

The energy_to_user register has different meanings on different inverter series:

  • SPH family: energy_to_user = Grid IMPORT energy (energy FROM grid TO load)
  • MIN TL-XH family: energy_to_user = Forward active energy (NOT grid import)

This caused MIN TL-XH to use the wrong register (3067-3068) for grid import, resulting in null/zero values.

Problem 2: Battery Discharge Counted as Solar Production

MIN TL-XH users reported:

  • Solar energy showing higher values than expected
  • Battery discharge energy being counted as solar production
  • Home energy calculations incorrect due to inflated solar values

Root Cause: The energy_today register (3049-3050) on MIN TL-XH represents total system AC output and includes battery discharge. When battery was discharging, this energy was incorrectly counted as solar production.

The Fix:

1. Restrict energy_to_user Hardware Register to SPH Family Only

Modified grid import energy calculation to only treat energy_to_user as grid import for SPH family profiles:

is_sph_family = inverter_series.startswith("sph_")
has_hardware_import = hasattr(data, "energy_from_grid_today") or (
    is_sph_family and hasattr(data, "energy_to_user_today")
)

This ensures MIN TL-XH no longer uses the wrong register for grid import calculations.

2. Derive MIN TL-XH Solar Energy from Energy Balance

For MIN TL-XH inverters, calculate true PV-only energy from energy balance terms:

pv_energy_today = load_energy + battery_charge + grid_export
                  - grid_import - battery_discharge

This ensures:

  • Battery discharge is NOT counted as solar production
  • Solar energy reflects actual PV generation only
  • Energy balance is mathematically correct

Impact:

Grid Import Energy:

  • ✅ MIN TL-XH now correctly calculates grid import energy
  • ✅ No longer uses wrong energy_to_user register
  • ✅ Grid import values are accurate and stable
  • ✅ SPH family continues to work correctly with energy_to_user register

Solar Energy Production:

  • ✅ Battery discharge no longer counted as solar
  • ✅ Solar energy shows accurate PV-only generation
  • ✅ Home energy calculations now correct
  • ✅ Energy balance mathematically accurate

Affected Versions:

  • Broken: v0.5.1 through v0.6.0 (grid import null/zero, battery counted as solar)
  • Working: v0.4.9 and earlier (used calculated import, but had battery discharge issue)
  • Fixed: v0.6.1 (both issues resolved)

Affected Models:

  • MIN TL-XH 3000-10000 V2.01 (all models in this series)

Migration Notes:

  • No action required - Updates apply automatically on restart
  • Grid import energy will immediately show correct values
  • Solar energy will decrease to accurate PV-only values (excluding battery discharge)
  • Historical data remains unchanged (new calculations start from restart)

Technical Details:

Files Changed:

  • custom_components/growatt_modbus/sensor.py:
    • Restricted energy_to_user to SPH family only (lines 1227, 1258)
    • Added MIN TL-XH energy balance calculation (lines 1295-1308)

Related Issues:

  • Fixes user report: Grid import null after v0.4.9 update
  • Fixes user report: Battery discharge counted as solar energy
  • Related to Issue #183 (SPH-TL3 grid energy fix that caused this regression)

Release Notes - v0.6.0

🔧 Fix - Battery Power Inversion for VPP Protocol Registers

This release fixes battery power sign interpretation issues where charge/discharge values appeared inverted on inverters using VPP Protocol V2.01 registers.

What Was Fixed:

  • Battery power registers now correctly interpret signed 16-bit values
  • Fixed battery power showing inverted signs (positive when should be negative)
  • Added proper register range detection (VPP vs fallback) to ensure consistent battery data
  • Improved fallback register detection with score-based approach

Impact:

  • ✅ SPH, SPM, and MIN TL-XH inverters now show correct battery power signs
  • ✅ Battery calculations (V×I) now match power register readings
  • ✅ Consistent battery data from detected register range

Release Notes - v0.5.8

🔧 Fix - Battery Power Sign Interpretation for VPP Protocol Registers

This release fixes battery power inversion issues where battery charge/discharge power values were showing with incorrect signs (positive when should be negative, or vice versa) on inverters using VPP Protocol V2.01 registers.

What Was Fixed:

Problem: Users with SPH, SPM, and MIN TL-XH inverters using VPP protocol registers reported battery power values showing with inverted signs:

  • Battery power showing large positive values (e.g., 56353W) when actually discharging at -918.3W
  • Charge/discharge direction appearing backwards in Home Assistant
  • Battery power calculations not matching voltage × current

Root Cause: Battery power registers in VPP protocol (31200-31209) use signed 16-bit values, but were being interpreted as unsigned integers. This caused:

  • Negative discharge values to wrap around to large positive numbers
  • Sign bit (0x8000) not being recognized
  • Example: -9183 (0xDC31) read as 56353 instead

Technical Details: The existing _get_register_value() method already had correct signed conversion logic (lines 664-668 for 32-bit, 682-686 for 16-bit), but only when the register definition includes 'signed': True. VPP battery power registers were missing this attribute.

The Fix:

Added 'signed': True to VPP battery power registers:

  1. SPH profiles (register 31203):

    • battery_charge_power_low now marked as signed
  2. TL_XH profiles (registers 31205, 31209):

    • charge_power_low now marked as signed
    • discharge_power_low now marked as signed
  3. MIN TL-XH profiles (registers 31205, 31209):

    • charge_power_low now marked as signed
    • discharge_power_low now marked as signed

Updated register descriptions:

# Before:
31205: {'name': 'charge_power_low', 'desc': 'Battery charge power (unsigned, positive=charging)'}

# After:
31205: {'name': 'charge_power_low', 'signed': True, 'desc': 'Battery charge power (signed: positive=charging, negative=discharging)'}

VPP vs Fallback Register Range Detection

Additionally, this release includes improved battery register fallback detection to ensure consistent data across all battery sensors.

The Challenge: Inverters may support multiple register ranges for battery data:

  • VPP registers (31200-31299): Modern VPP Protocol V2.01 with signed values
  • Fallback registers (3000-3999): Legacy range with unsigned/different conventions

Previous implementation would try both ranges independently for each sensor, which could:

  • Mix VPP and fallback values across different sensors
  • Not distinguish between "legitimately zero" vs "wrong register range"
  • Cause inconsistent battery power calculations

The Solution:

  • Detect which register range is active (VPP vs fallback) once per session
  • Check multiple key battery sensors (voltage, SOC, power, energy) for non-zero values
  • Use score-based detection: whichever range has more non-zero values wins
  • Use the detected range consistently for ALL battery sensors
  • Default to fallback if both ranges are zero (more universal)

This ensures:

  • Proper sign interpretation based on register range (VPP=signed, fallback=may vary)
  • Consistent data source across all battery sensors
  • No mixing of VPP and fallback register data
  • Correct handling of legitimate zero values

Impact:

  • SPH inverters: Battery power now shows correct sign (VPP registers properly signed)
  • MIN TL-XH inverters: Battery power direction correct (VPP registers properly signed)
  • All VPP-enabled profiles: Consistent battery data from detected register range
  • Fallback registers: Still work correctly when VPP registers unavailable
  • Battery calculations: V×I now matches power register readings

Affected Models:

Fixed by VPP register signing:

  • SPH 3-6kW, 7-10kW (VPP Protocol V2.01)
  • SPM series
  • MIN TL-XH 3000-10000 (VPP Protocol V2.01)
  • MOD TL3-XH series

Improved by register range detection:

  • All models with both VPP and fallback battery registers

Code Changes:

Profiles (sph.py, tl_xh.py):

  • Added 'signed': True to battery power registers 31203, 31205, 31209
  • Updated register descriptions to clarify sign conventions

Core Logic (growatt_modbus.py):

  • Added _battery_register_range detection logic
  • Score-based detection across multiple battery sensors
  • Consistent range usage via _get_register_value_with_fallback()

Files Changed:

  • custom_components/growatt_modbus/profiles/sph.py: Signed battery power registers
  • custom_components/growatt_modbus/profiles/tl_xh.py: Signed battery power registers
  • custom_components/growatt_modbus/growatt_modbus.py: VPP vs fallback range detection

🔧 Fix - WIT Sensors No Longer Appear on Non-WIT Profiles

This release fixes a sensor visibility issue where WIT-specific sensors (battery_soh and battery_voltage_bms) incorrectly appeared on non-WIT inverter profiles, showing confusing 0 values.

What Was Fixed:

Problem: Users with non-WIT inverters (MIN TL-XH, SPH, MOD, etc.) reported seeing WIT-only battery sensors that always showed 0:

  • Battery State of Health (SOH): 0%
  • Battery Voltage BMS: 0V

These sensors are only valid for WIT series inverters (WIT 4-15kW), which have specialized battery management registers.

Root Cause: The battery_soh and battery_voltage_bms attributes were defined in the GrowattData dataclass with default values of 0.0. This meant hasattr(data, 'battery_soh') always returned True, causing Home Assistant to create sensors for all inverter profiles regardless of whether they actually support these registers.

Evidence:

  • MIN TL-XH profile: No registers 8094 (battery_soh) or 8095 (battery_voltage_bms)
  • SPH TL3 profile: No WIT battery registers
  • WIT profile: Has registers 8094 and 8095 ✅

The Fix:

Changed sensor creation logic:

  1. Removed from dataclass defaults: battery_soh and battery_voltage_bms no longer have default 0.0 values in GrowattData

  2. Set dynamically only: These attributes are now only created via setattr() when:

    • The profile has the corresponding registers (8094, 8095)
    • The registers have valid data
  3. Matches BMS sensor pattern: This follows the same approach used for other advanced sensors like bms_soh, bms_constant_volt, etc.

Impact:

  • WIT inverters (WIT 4-15kW): Sensors still created normally (registers exist)
  • MIN TL-XH inverters: WIT sensors no longer appear (eliminated confusion)
  • SPH, MOD, TL-XH: No WIT sensors (cleaner sensor list)
  • No user confusion: Only see sensors your inverter actually supports

Code Changes:

Lines 216-217 (growatt_modbus.py):

# Before:
battery_soh: float = 0.0          # % (State of Health - WIT)
battery_voltage_bms: float = 0.0  # V (BMS voltage reading - WIT)

# After:
# battery_soh and battery_voltage_bms are WIT-only - set dynamically if register exists

Lines 1724-1737 (growatt_modbus.py):

# Changed from direct assignment to conditional setattr:
if addr:
    value = self._get_register_value(addr)
    if value is not None:
        setattr(data, 'battery_soh', value)  # Only set if register exists

Affected Models:

Benefit from this fix (cleaner sensor list):

  • MIN TL-XH 3000-10000
  • SPH 3-6kW, 7-10kW, SPH-TL3
  • MOD 6000-15000TL3-XH
  • MIC, MIN, MID, TL-XH series
  • SPF off-grid series

Still see these sensors (as intended):

  • WIT 4000-15000TL3 (only series with these registers)

Migration Notes:

  • No action required - Updates apply automatically on restart
  • WIT sensors will disappear from non-WIT inverters
  • No impact on actual functionality, only sensor visibility
  • Historical data unaffected

Files Changed:

  • custom_components/growatt_modbus/growatt_modbus.py: Updated GrowattData dataclass and battery data reading logic
  • custom_components/growatt_modbus/manifest.json: Version bumped to 0.5.8
  • README.md: Version badge updated to 0.5.8

Release Notes - v0.5.7

🔧 Critical Fix - MIN TL-XH Battery Registers Corrected (Issue #191)

This release fixes a critical battery sensor issue for MIN TL-XH 3000-10000 V2.01 inverters where all battery sensors (voltage, current, SOC, temperature) showed zero or incorrect values.

What Was Fixed:

Problem: MIN TL-XH users with battery storage (e.g., MIN-4600TL-XH with ARK battery) reported zero values for all battery sensors:

  • Battery voltage: 0V (should be ~212V)
  • Battery current: 0A
  • Battery SOC: 0% (should be actual percentage like 54%)
  • Battery temperature: 0°C (should be actual temp like 21.2°C)

Root Cause: The MIN TL-XH V2.01 profile was using VPP Protocol registers (31200+ range) for battery state, based on the official Growatt VPP Protocol V2.01 specification. However, user scan data proved that MIN TL-XH inverters do NOT use the VPP 31200+ range for battery state - they use the 3000+ range (similar to MOD series layout).

Evidence from user register scan:

  • VPP range (31200-31222): ALL ZEROS

    • 31214 battery_voltage: 0
    • 31215 battery_current: 0
    • 31217 battery_soc: 0
    • 31222 battery_temp: 0
  • 3000+ range: HAS BATTERY DATA

    • 3169: 21194 → 211.94V (scale 0.01)
    • 3170: battery current (scale 0.1)
    • 3171: 54 → 54% SOC
    • 3176: 212 → 21.2°C battery temp (scale 0.1)

The Fix:

For MIN_TL_XH_3000_10000_V201 profile:

  1. Added PRIMARY battery state registers at 3169-3176 (3000+ range):

    • 3169: battery_voltage (scale 0.01, note different scale than VPP!)
    • 3170: battery_current (scale 0.1, signed)
    • 3171: battery_soc (scale 1)
    • 3176: battery_temp (scale 0.1, signed)
  2. Renamed VPP 31200+ battery registers with _vpp suffix:

    • 31214: battery_voltage_vpp (not used on MIN TL-XH)
    • 31215: battery_current_vpp (not used on MIN TL-XH)
    • 31217: battery_soc_vpp (not used on MIN TL-XH)
    • 31222: battery_temp_vpp (not used on MIN TL-XH)
  3. Important scale difference: Battery voltage uses scale 0.01 in 3000+ range vs 0.1 in VPP range!

Impact:

  • MIN TL-XH with battery: All battery sensors now show correct values
  • ✅ Battery voltage shows actual voltage (e.g., 211.94V instead of 0V)
  • ✅ Battery SOC shows actual percentage (e.g., 54% instead of 0%)
  • ✅ Battery temperature shows actual temp (e.g., 21.2°C instead of 0°C)
  • ✅ MIN TL-XH now uses MOD-like register layout for battery state

Affected Models:

  • MIN TL-XH 3000-10000 V2.01 with battery storage (e.g., MIN-4600TL-XH with ARK battery)

Technical Background:

The VPP registers were originally added in November 2025 based on the official Growatt VPP Communication Protocol V2.01 specification (dated 2024.9.20), which documented the 31200+ range for battery information. The protocol specification was assumed to apply to all V2.01 inverters including MIN TL-XH.

However, user feedback proved this assumption was incorrect for MIN TL-XH - these inverters follow the MOD series register layout (3000+ range) for battery state, not the VPP protocol layout. This is a case where real-world hardware behavior differs from the protocol specification.

Files Changed:

  • custom_components/growatt_modbus/profiles/tl_xh.py:
    • MIN_TL_XH_3000_10000_V201: Added registers 3169-3176 as primary battery state
    • Renamed VPP registers 31214/31215/31217/31222 with _vpp suffix
  • custom_components/growatt_modbus/manifest.json: Version bumped to 0.5.7
  • README.md: Version badge updated to 0.5.7

Migration Notes:

  • No action required - Updates apply automatically on restart
  • Battery sensors will immediately show correct values
  • If you previously had 0V/0%/0°C, values will now reflect actual battery state
  • Historical data remains unchanged (new readings start from restart)

Related Issues:

  • Fixes #191 - MIN TL-XH battery sensors showing zero
  • User-confirmed: 3000+ range contains correct battery data, VPP range returns zeros

Release Notes - v0.5.6

🔧 Critical Fix - SPH Battery SOC Register Priority (Issue #185)

This release fixes a critical battery SOC (State of Charge) reading issue for SPH 3-6kW and 7-10kW V2.01 inverters where the SOC sensor disappeared or showed 0% after upgrading to v0.5.4+.

What Was Fixed:

Problem: After upgrading to v0.5.4+, some SPH users reported that battery SOC disappeared or showed 0% instead of the actual value:

  • Battery SOC sensor showing 0% despite battery being charged (e.g., should be 100%)
  • Register 17 (legacy) returns incorrect value (0%)
  • Register 31217 (VPP range) contains the correct SOC value
  • The integration was reading register 17 first due to register lookup priority

Root Cause: The _find_register_by_name('battery_soc') function searches input registers in insertion order and returns the first name match. Even though register 1086 was added in v0.5.5 as an "override" for standard SPH V201 models:

  1. Register 17 (inherited from base profile) with name='battery_soc' was found first
  2. Register 1086 with name='battery_soc' was never reached
  3. Register 31217 with maps_to='battery_soc' was never reached
  4. Result: Integration read register 17 (shows 0%) instead of register 31217 (correct value)

The Fix:

For SPH 3-6kW and 7-10kW V2.01 profiles:

  1. Renamed register 17 to battery_soc_legacy (prevents name match)
  2. Removed register 1086 (BMS SOC) from standard SPH V201 profiles
    • Register 1086 is only valid for HU models with Battery Management System
    • Standard SPH 3-6kW/7-10kW models don't have BMS, so register 1086 may not respond
  3. Uses register 31217 (VPP range) as primary SOC source via maps_to='battery_soc'
    • User-confirmed working in Issue #185
    • Matches VPP Protocol V2.01 specification

Impact:

  • SPH 3-6kW V2.01: Battery SOC now reads from register 31217 (correct value)
  • SPH 7-10kW V2.01: Battery SOC now reads from register 31217 (correct value)
  • ✅ Register priority fixed: 31217 (VPP) instead of 17 (legacy 0%)
  • ✅ HU models unaffected (still use register 1086 BMS SOC)

Affected Models:

  • SPH 3000-6000 V2.01 (standard, non-HU)
  • SPH 7000-10000 V2.01 (standard, non-HU)

Files Changed:

  • custom_components/growatt_modbus/profiles/sph.py:
    • SPH_3000_6000_V201: Renamed register 17, removed register 1086
    • SPH_7000_10000_V201: Renamed register 17, removed register 1086
  • custom_components/growatt_modbus/manifest.json: Version bumped to 0.5.6
  • README.md: Version badge updated to 0.5.6

Migration Notes:

  • No action required - Updates apply automatically on restart
  • Battery SOC sensor will immediately show correct percentage
  • If you previously had 0% SOC, it will now show actual battery charge level
  • Historical data remains unchanged (new readings start from restart)

Related Issues:

  • Fixes #185 - SPH3-6k battery SOC showing 0% after upgrade
  • User-confirmed: Register 31217 contains correct SOC value

Release Notes - v0.5.5

🔧 Bug Fix - SPH 7-10kW Battery Sensor Fixes

This release applies the same battery sensor fixes from v0.5.1 (SPH 3-6kW) to the SPH 7-10kW V2.01 profile, ensuring consistent and accurate battery monitoring across all SPH models.

What Was Fixed:

Problem: SPH 7-10kW V2.01 users were experiencing the same battery sensor issues that were fixed for SPH 3-6kW in v0.5.1, but the fixes were never applied to the 7-10kW profile:

  • Battery SOC showing 0% instead of actual value (e.g., should be 85%)
  • Battery energy registers showing incorrect values
  • AC charge energy sensor potentially showing garbage values

Root Cause: The battery sensor fixes from v0.5.1 (commit 9c71de7) were only applied to SPH_3000_6000_V201 but not to SPH_7000_10000_V201, leaving 7-10kW users with the same issues.

The Fix:

Applied all three fixes to SPH_7000_10000_V201 profile:

1. Battery SOC Fix:

  • Added register 1086 for battery_soc (BMS value)
  • Overrides inherited register 17 which shows 0
  • Provides correct SOC reading from battery management system

2. Battery Energy Registers Fix:

  • Changed registers 31202-31203 from battery_charge_power to battery_discharge_today (energy)
  • Added registers 31204-31205 for battery_charge_total (kWh)
  • Added registers 31206-31207 for battery_charge_today (kWh)
  • Added registers 31208-31209 for battery_discharge_total (kWh)
  • Matches VPP Protocol V2.01 specification and real-world register data

3. AC Charge Energy Fix:

  • Added register 115 for ac_charge_energy_total
  • Prevents incorrect 32-bit pairing of registers 31220-31221
  • Avoids garbage values like 70M+ kWh

Impact:

  • SPH 7-10kW battery SOC now shows correct percentage (was 0%)
  • ✅ Battery energy tracking now accurate (charge/discharge today & total)
  • ✅ AC charge energy sensor shows correct values
  • Full parity with SPH 3-6kW fixes from v0.5.1

Affected Models:

  • SPH 7000-10000 V2.01 (single-phase hybrid with VPP protocol)

Files Changed:

  • custom_components/growatt_modbus/profiles/sph.py:
    • Line ~579: Added register 1086 (battery_soc from BMS)
    • Lines ~667-675: Fixed battery energy registers 31202-31209
    • Line ~686: Added register 115 (ac_charge_energy_total)

Migration Notes:

  • No action required - Updates apply automatically on restart
  • Battery sensors will show correct values immediately
  • Historical data remains unchanged (new readings start from restart)

Release Notes - v0.5.4

🔧 Bug Fix & Enhancement - Register Scan Improvements (Issue #184)

This release improves the diagnostic register scan service to provide better visibility and reduce confusion when troubleshooting profile selection issues.

What Was Fixed:

Problem: Users manually selecting a profile (e.g., "MIN TL-XH") would run the register scan service and see only the auto-detected profile (e.g., "MOD series") in the CSV output. This caused confusion because:

  • The CSV only showed "Suggested Profile Key: mod_6000_15000tl3_xh" (auto-detected)
  • It didn't show what profile the user had actually selected and was using
  • Users thought the suggested profile was what they had configured

Impact:

  • User's system was actually working correctly with the selected profile
  • But they couldn't see this in the diagnostic output
  • Led to confusion and unnecessary troubleshooting

What's New:

1. Currently Configured Profile Display

The register scan CSV now shows both the selected profile AND the auto-detected profile:

SCAN METADATA
Connection Type,TCP
Slave ID,1

CURRENTLY CONFIGURED PROFILE
Selected Profile,MIN TL-XH 3000-10000
Selected Profile Key,min_tl_xh_3000_10000_v201

DETECTION ANALYSIS
Detected Model,MOD Series 6000-15000TL3-XH
Suggested Profile Key,mod_6000_15000tl3_xh

This makes it clear:

  • ✅ What profile you have configured and are currently using
  • ✅ What profile the auto-detection suggests
  • ✅ Whether there's a mismatch between selected and detected

2. Current Entity Values Section

The register scan now includes a comprehensive snapshot of all current entity values from Home Assistant:

CURRENT ENTITY VALUES FROM INTEGRATION
Entity Name,Current Value
ac_current,5.234
ac_frequency,50.020
ac_power,1234.567
ac_voltage,230.123
battery_charge_power,0.000
battery_current,2.345
battery_power,567.890
battery_soc,85.000
battery_temp,None (unavailable)
battery_voltage,51.234
energy_today,12.345
grid_power,1234.567
house_consumption,567.890
pv1_current,6.789
pv1_power,1234.567
pv1_voltage,182.345
...

Features:

  • ✅ Shows all entity values including zeros and unavailable
  • ✅ Clearly marks unavailable values as "None (unavailable)"
  • ✅ Alphabetically sorted for easy lookup
  • ✅ Formatted for readability (floats to 3 decimals)

Benefits for debugging:

  • Compare raw register values vs. processed entity values
  • See complete snapshot of integration state at scan time
  • Identify which values are zero vs. missing vs. unavailable
  • Verify entity processing and calculations

Files Changed:

  • custom_components/growatt_modbus/diagnostic.py:
    • Added imports for profile display name functions
    • Extract currently selected profile from coordinator
    • Extract all current entity values from coordinator data
    • Display both sections in CSV before detection analysis

Migration Notes:

  • No action required - Enhancement is automatic
  • Works when register scan finds a matching integration (same connection)
  • If no integration found, shows detection analysis only (as before)

Release Notes - v0.5.3

🔧 Bug Fix - Missing Battery BMS Temperature Register (Issue #184)

This release fixes an issue where register 3136 (battery BMS temperature) was undefined in MOD and MIN TL-XH profiles, causing incorrect sensor values in Home Assistant.

What Was Fixed:

Problem: Users reported seeing duplicate/incorrect battery sensors:

  • "Battery charging from mains power: 36.60 kWh" (incorrect - actually a temperature!)
  • "Boost Temperature: 0.0°C" (incorrect - register 95 reads 0)
  • Missing battery BMS temperature sensor

Root Cause:

  • Register 3136 was not defined in MOD 6000-15000TL3-XH and MIN TL-XH profiles
  • Raw value: 366 (36.6 with ×0.1 scale)
  • Integration misinterpreted this as energy data (36.60 kWh) instead of temperature (36.6°C)
  • Register is in the 3000+ extended range used by both MOD and MIN profiles

Additional Issue:

  • User had MIN 3000 TL-XH (single-phase) but auto-detection selected MOD profile (three-phase)
  • Phase S/T registers all showed 0, confirming single-phase inverter
  • Wrong profile caused incorrect register mappings and missing/duplicate sensors

The Fix:

Added missing battery BMS temperature register to both profiles:

  1. MOD 6000-15000TL3-XH Profile (profiles/mod.py):

    • Register 96: temp_sensor_1 (36.6°C - additional BMS/battery temperature)
    • Register 97: temp_sensor_2 (32.7°C - matches Growatt server Boost Temp)
    • Register 3136: battery_bms_temp (36.6°C - battery BMS/module temperature)
  2. MIN TL-XH 3000-10000 Profile (profiles/tl_xh.py):

    • Register 3136: battery_bms_temp (36.6°C - battery BMS/module temperature)

Why Both Profiles:

  • Register 3136 is in the 3000+ extended range shared by both MOD and MIN inverters
  • Registers 96-97 are MOD-specific (0-124 base range, not used by MIN)
  • Fix benefits both actual MOD users and users who should be using MIN profile

Impact:

  • ✅ New sensor: "Battery BMS Temp" showing correct temperature (36.6°C)
  • ✅ Removes incorrect "Battery charging from mains power: 36.60 kWh" sensor
  • ✅ Properly identifies temperature vs energy data
  • ✅ Fixes duplicate sensor issues for MOD/MIN TL-XH users

📋 Action Required:

For users with MIN 3000 TL-XH inverters:

  1. Update to v0.5.3

  2. Reconfigure to correct profile:

    • Go to: Settings → Devices & Services → Growatt
    • Click Configure on your inverter
    • Change profile to: MIN TL-XH 3000-10000 (V2.01)
    • Save and restart Home Assistant
  3. Verify after restart:

    • ✅ "Battery BMS Temp" sensor appears (~36.6°C)
    • ❌ Incorrect "36.60 kWh" sensor removed
    • ✅ Battery power sensors still work correctly
    • ✅ Three-phase sensors (Phase S/T) hidden

For users with actual MOD inverters:

  • Simply update to v0.5.3 and restart
  • New temperature sensors will appear automatically

Technical Details:

Register Analysis from Scan (2026-03-09 14:12:43):

  • Register 96 (base range): 366 raw = 36.6°C
  • Register 97 (base range): 327 raw = 32.7°C (matches Growatt server)
  • Register 3136 (extended): 366 raw = 36.6°C
  • Battery charging: 2.14kW (Growatt server), 1626W (register 3181) ✓ correct
  • Phase S/T registers: All 0 → Single-phase → MIN profile needed

Files Changed:

  • custom_components/growatt_modbus/profiles/mod.py (lines 77-78, 123)
  • custom_components/growatt_modbus/profiles/tl_xh.py (line 312)

Affected Models:

  • MOD 6000-15000TL3-XH (three-phase hybrid)
  • MIN TL-XH 3000-10000 (single-phase hybrid)
  • Any inverter using these profiles with battery BMS temperature at register 3136

Detection Improvement Needed:

  • Auto-detection currently selects MOD for MIN inverters
  • Future improvement: Check phase S/T registers to distinguish single vs three-phase

Release Notes - v0.5.2

🔧 Critical Bug Fix - Integration Initialization Failure (Issue #188)

This release fixes a critical bug where the integration fails to initialize on inverters that don't support extended register ranges added in v0.5.0.

What Was Fixed:

Problem: After upgrading to v0.5.*, some users reported:

  • Integration stuck in "Initializing" state with constant retrying
  • Error in logs: ExceptionResponse(dev_id=1, function_code=132, exception_code=4)
  • Error message: Modbus error reading input registers 3000-3078
  • Downgrading to v0.4.8 resolves the issue

Root Cause:

  • In v0.5.0, registers 3071-3078 were added to SPH V2.01 profiles for load energy and grid export energy metrics
  • These registers are in the MIN/MOD range (3000-3124) which not all inverters support
  • When reading the 3000 range, inverters without these registers return Modbus exception code 4 (Slave Device Failure)
  • The code treated this as a fatal error and aborted initialization by returning None
  • This was inconsistent with how other register ranges (storage 1000-1124, business 875-999) handle failures

The Fix:

Changed 3000 range register read failure handling from fatal to graceful degradation:

  1. Non-Fatal Error Handling:

    • Changed from logger.error() + return None to logger.warning() + continue
    • Matches the pattern used for storage and business register ranges
    • Allows initialization to complete even if extended registers aren't available
  2. Graceful Degradation:

    • Inverters with extended registers: Get full data including load energy metrics
    • Inverters without extended registers: Work normally with core functionality
    • No user intervention required - automatic compatibility

Impact:

  • ✅ Integration initializes successfully on all inverter models
  • ✅ Fixes "stuck in Initializing" issue reported in #188
  • ✅ Backward compatible with inverters lacking extended register support
  • ✅ Forward compatible - still provides enhanced data when registers are available
  • ✅ No configuration changes needed

📋 Action Required:

For users experiencing initialization failures:

  1. Update to v0.5.2
  2. Restart Home Assistant
  3. Verify integration initializes successfully:
    • Integration should complete initialization within 30 seconds
    • No more "Initializing" stuck state
    • All supported sensors should appear and update normally

No configuration changes needed - fix is automatic after upgrade.

Technical Details:

Files Changed:

  • custom_components/growatt_modbus/growatt_modbus.py:824-825

What Changed:

  • Modified _read_registers() method to handle 3000 range read failures gracefully
  • Changed error handling from fatal (return None) to warning (continue)
  • Inverters report Modbus exception code 4 when unsupported registers are requested
  • Integration now continues with available data instead of aborting

Affected Models:

  • All inverter models that don't support registers 3071-3078 (load energy, grid export in MIN/MOD range)
  • Primarily affects inverters without VPP V2.01 protocol extended register support
  • Fixes compatibility regression introduced in v0.5.0

🚀 Enhancement - MIC Auto-Detection Fix for Waveshare Adapters (Issue #187)

This release fixes auto-detection timeouts for MIC micro inverters when using Waveshare RS485-to-ETH adapters.

What Was Fixed:

Problem: MIC 3000TLX users with Waveshare RS485-ETH adapters reported:

  • Integration hangs at "off-grid inverter warning" screen during setup
  • Setup takes ~10 minutes instead of completing immediately
  • Logs show: No response received after 3 retries when reading register 30000
  • Integration eventually times out and fails to initialize

Root Cause:

  • MIC micro inverters use legacy V3.05 protocol (registers 0-179 only)
  • Auto-detection was attempting to read VPP 2.01 register 30000 before checking legacy registers
  • MIC doesn't support register 30000, causing long timeout with Waveshare adapters
  • Legacy register detection (which includes MIC) only ran AFTER the VPP timeout

The Fix:

Added early legacy register detection before attempting VPP register reads:

  1. Quick Legacy Check (Step 1.5):

    • Try reading register 3 (PV1 voltage) - exists in most legacy protocols
    • If register 3 responds, check if register 3003 is absent
    • Register 3 present + register 3003 absent = MIC series (0-179 range only)
  2. Skip VPP Detection:

    • Once MIC is detected via legacy registers, skip reading register 30000
    • Prevents long timeout on unsupported VPP registers
    • Detection completes in <1 second instead of ~10 minutes
  3. Detection Order Updated:

    • Step 1: OffGrid DTC (registers 34/43) - SPF detection
    • Step 1.5: Legacy register check (NEW) - MIC detection
    • Step 2: VPP DTC (register 30000) - V2.01 inverters
    • Step 3: Model name read
    • Step 4: Register probing (fallback)

Impact:

  • ✅ MIC inverters detected immediately via legacy registers
  • ✅ No timeout on unsupported VPP register 30000
  • ✅ Setup completes in <1 second instead of ~10 minutes
  • ✅ Works with all RS485-to-TCP adapters including Waveshare
  • ✅ No impact on other inverter models

📋 Waveshare RS485-to-ETH Configuration

For users with Waveshare RS485-to-ETH adapters, use these settings:

Connection Parameters:

  • Baud Rate: 9600
  • Data Bits: 8
  • Parity: None
  • Stop Bits: 1
  • Port: 502 (Modbus TCP standard)
  • Reset: Off
  • Link: On
  • Index: Off
  • RFC2217 (Similar): On

These settings are now documented in the README for reference.

Technical Details:

Files Changed:

  • custom_components/growatt_modbus/auto_detection.py:923-945
  • README.md:118-131 (added Waveshare configuration guide)

Detection Logic:

# Before: VPP DTC read first → timeout on MIC
1. OffGrid DTCVPP DTCModel nameRegister probing

# After: Legacy check before VPP → instant MIC detection
1. OffGrid DTCLegacy check (MIC) → VPP DTCModel nameRegister probing

Affected Models:

  • MIC 600-3300TL-X series (all micro inverters using 0-179 register range)
  • Any legacy inverter using V3.05 protocol without VPP 2.01 support
  • Particularly affects users with Waveshare RS485-to-ETH adapters

Release Notes - v0.5.1

🔧 Bug Fixes - SPH Battery & Grid Energy Sensors

This release fixes critical sensor issues for SPH inverters including battery sensor inaccuracies and grid energy calculation errors.

What Was Fixed:

Problem: SPH 3-6kW V2.01 users reporting incorrect battery sensor values (Issue #185):

  • Battery SOC showing 0% instead of actual value (e.g., 31%)
  • AC Charge Energy Total showing garbage value (70,516,736 kWh)
  • Battery charge/discharge energy sensors showing incorrect or missing values

Root Cause:

  • Register 17 (inherited from base profile) returns 0 for SOC on V2.01 inverters
  • Correct SOC value is available in register 1086 (BMS register) but wasn't configured
  • Battery energy registers in VPP range (31202-31209) were incorrectly mapped
  • AC Charge Energy Total used wrong 32-bit register pairing (31220-31221)

The Fix:

  1. Added Correct Battery SOC Register:

    • Added register 1086 for battery_soc in SPH 3-6kW V2.01 profile
    • Overrides inherited register 17 which returns 0
    • Provides accurate SOC value directly from BMS
  2. Fixed Battery Energy Register Mappings:

    • Changed registers 31202-31203 from power to discharge_today energy
    • Added registers 31204-31205 for battery_charge_total
    • Added registers 31206-31207 for battery_charge_today
    • Added registers 31208-31209 for battery_discharge_total
    • All battery energy tracking now accurate
  3. Fixed AC Charge Energy Total:

    • Removed incorrect 32-bit pairing of registers 31220-31221
    • Added register 115 for ac_charge_energy_total
    • Prevents garbage value of 70,516,736 kWh

Impact:

  • ✅ Battery SOC now shows correct value (e.g., 31% instead of 0%)
  • ✅ AC Charge Energy Total shows realistic value (e.g., 7.8 kWh instead of 70M kWh)
  • ✅ Battery charge/discharge energy sensors now accurate
  • ✅ Complete battery monitoring for SPH 3-6kW V2.01 users

🔧 Bug Fix - SPH-TL3 Grid Import Energy Calculation (Issue #183)

This release fixes incorrect grid import energy values for SPH-TL3 inverters where the energy sensor would show decreasing values or incorrect totals.

What Was Fixed:

Problem: SPH-TL3 users reporting incorrect grid import energy:

  • Grid import energy showing values that decrease when solar production starts
  • Calculated values significantly different from actual grid consumption
  • Energy meters not reflecting true grid import

Root Cause:

  • SPH-TL3 has hardware registers for grid import energy (energy_to_user_today at 1044-1045 and energy_to_user_total at 1046-1047)
  • Code was checking for energy_from_grid_today/total which don't exist on SPH-TL3
  • This caused fallback to calculation: import = load - solar + export
  • Calculation was incorrect for hybrid inverters because solar (energy_today) includes both PV generation AND battery discharge
  • When solar production increased, calculated import energy would decrease (mathematically incorrect)

The Fix:

Modified sensor.py to check for energy_to_user_today/total registers and use them directly when available:

  1. Added Hardware Register Support:

    • Check for registers 1044-1045 (energy_to_user_today) for daily grid import
    • Check for registers 1046-1047 (energy_to_user_total) for total grid import
    • Use hardware meter readings directly instead of calculation
  2. Improved CT Clamp Handling:

    • Normal orientation + hardware register: use energy_to_user directly
    • CT clamp backwards + hardware register: use energy_to_grid (swapped)
    • No hardware register available: fall back to calculation (MIN series, etc.)
  3. Accurate Grid Import Tracking:

    • Values now come directly from hardware meter
    • No dependency on PV production or battery discharge calculations
    • Grid import energy never decreases incorrectly

Impact:

  • ✅ SPH-TL3 grid import energy now accurate from hardware registers
  • ✅ Values stable and don't decrease when solar production starts
  • ✅ Proper handling of CT clamp orientation (normal vs backwards)
  • ✅ Fallback calculation still works for inverters without hardware registers
  • ✅ Fixes issue #183

📋 Action Required for SPH Users:

For SPH 3-6kW V2.01 inverters:

  1. Update to v0.5.1
  2. Restart Home Assistant
  3. Verify sensors show correct values:
    • Battery SOC should show actual percentage (not 0%)
    • AC Charge Energy Total should be realistic (not millions of kWh)
    • Battery energy today/total sensors should update properly

For SPH-TL3 inverters:

  1. Update to v0.5.1
  2. Restart Home Assistant
  3. Verify grid import energy:
    • Grid import energy should be stable and accurate
    • Values should not decrease when solar production increases
    • Energy readings should match your actual grid consumption

No configuration changes needed - fixes are automatic after upgrade.

Technical Details:

Files Changed:

  • custom_components/growatt_modbus/profiles/sph.py (SPH 3-6kW battery sensors)
  • custom_components/growatt_modbus/sensor.py (SPH-TL3 grid energy calculation)

SPH 3-6kW Battery Fix - Registers Added/Modified:

  • 1086: battery_soc (overrides register 17)
  • 115: ac_charge_energy_total (replaces incorrect 31220-31221 pair)
  • 31202-31203: battery_discharge_today (was incorrectly mapped as power)
  • 31204-31205: battery_charge_total (newly added)
  • 31206-31207: battery_charge_today (newly added)
  • 31208-31209: battery_discharge_total (newly added)

SPH-TL3 Grid Energy Fix - Registers Used:

  • 1044-1045: energy_to_user_today (daily grid import from hardware meter)
  • 1046-1047: energy_to_user_total (total grid import from hardware meter)
  • Fallback calculation for inverters without hardware registers (MIN series, etc.)

Affected Models:

  • Battery sensor fix: SPH 3000-6000 (V2.01 protocol only)
  • Grid energy fix: SPH-TL3 (all versions with hardware meter registers)
  • Does not affect SPH 7-10kW or other SPH models

⚠️ Known Issue - MIC-1000TL-X Profile Selection (Issue #130)

Some MIC-1000TL-X inverters (firmware "PV 1000") may show zero values for AC power, energy today, energy total, AC current, and AC frequency when using the "MIC 600-3300TL-X (V2.01)" profile.

Problem:

MIC-1000TL-X inverters can have two different register layouts:

  1. Standard layout (0-179 range): AC data at registers 11-12, 26-27
  2. Hybrid MIN layout (0-124 + 3000-3124 range): AC data at registers 3028-3029, 3049-3050

If you selected "MIC 600-3300TL-X (V2.01)" but your inverter uses the hybrid MIN layout, the integration will read the wrong registers and show zeros.

Solution:

  1. Go to Settings → Devices & Services → Integrations
  2. Find your Growatt Modbus integration
  3. Click Configure
  4. Change Inverter Series to: MIC 1000-6000TL-X (MIN range)
  5. Click Submit
  6. Restart Home Assistant

After restart, all sensors should show correct values.

How to Identify if You Need This:

  • Inverter model: MIC-1000TL-X (or similar MIC models 1-3.3kW)
  • Firmware: "PV 1000" or similar
  • Symptoms: AC power = 0, Energy today = 0, but PV power shows correct values
  • Profile needed: MIC 1000-6000TL-X (MIN range)

Note: The profile name says "1000-6000" but works for all MIC inverters (including MIC-1000TL-X) that use the hybrid MIN register layout. The auto-detection should select this automatically, but if you manually selected a profile, you may need to change it.


Release Notes - v0.5.0

🔧 Critical Bug Fix - Diagnostic DTC Detection

This release fixes a critical bug in the diagnostic scanner that caused incorrect profile suggestions for VPP 2.01 inverters.

What Was Fixed:

Problem: Diagnostic scanner incorrectly overriding DTC-based detection with register-based detection:

  • DTC code would correctly identify inverter model (e.g., DTC 3501 = SPH 3-6kW)
  • Register-based detection would then override with wrong model (e.g., SPH 8-10kW HU)
  • Users ended up with wrong profile selection, causing missing or incorrect sensors

Root Cause:

  • Diagnostic scanner performed DTC detection first
  • Then continued to register-based detection logic
  • Register-based detection would override correct DTC mapping
  • Example: SPH 3-6kW V2.01 has storage range (1000+) which triggered HU detection

The Fix:

  • Added early exit after successful DTC detection
  • Register-based detection now only runs if DTC detection fails
  • DTC detection takes priority as most reliable method

Impact:

  • ✅ DTC 3501 (SPH 3-6kW) now correctly suggests sph_3000_6000_v201 instead of sph_8000_10000_hu
  • ✅ All VPP 2.01 inverters with valid DTC codes get correct profile suggestions
  • ✅ Battery sensors work correctly with proper profile

📋 Action Required for Existing Users:

If you previously ran the diagnostic scanner and it suggested the wrong profile, you need to update your configuration:

Symptoms of wrong profile:

  • Missing battery sensors
  • Incorrect power readings
  • Diagnostic showed different model than what you selected

How to Fix:

  1. Update to v0.5.0
  2. Re-run diagnostic scanner (it will now show correct profile)
  3. Update your integration configuration:
    • Go to: Settings → Devices & Services → Integrations
    • Find Growatt Modbus integration
    • Click Configure
    • Change Inverter Series to match diagnostic suggestion
    • Click Submit
  4. Restart Home Assistant

Common Corrections:

  • DTC 3501/3502: Change from SPH 8-10kW HUSPH 3-6kW (V2.01)
  • DTC 3501/3502: Change from SPH 7-10kWSPH 3-6kW (V2.01)

Technical Details:

File Changed: diagnostic.py

Code Added:

# If DTC detected model, skip other detection logic
if detection["confidence"] == "Very High":
    return detection

This ensures DTC-based detection (confidence = "Very High") takes priority and prevents register-based detection from overriding the correct profile.

Affected DTC Codes:

  • 3501, 3502, 3735 (SPH/SPA 3-6kW)
  • 3601, 3725 (SPH/SPA TL3)
  • 5100 (TL-XH)
  • 5200, 5201 (MIN/MIC)
  • 5400 (MOD-XH/MID-XH)
  • 5603, 5601, 5800 (WIT/WIS)

Release Notes - v0.4.9

🔧 Bug Fixes + ✨ New Features + 🎯 WIT/SPH Enhancements

This release combines all improvements from beta versions (v0.4.9b1-b4) plus additional bug fixes.

Fixed:

  • Battery power sign inversion for VPP protocol registers (1013-1014 swapped)
  • Missing energy and battery registers in SPH V2.01 profiles (Issue #176)
  • Multiple inverters on same IP rejected with "already configured" (Issue #179)
  • SPH TL3 Energy Today showing AC output instead of PV production (Issue #172)

Added:

  • Multi-register write support for advanced Modbus operations
  • WIT VPP battery control entities and services (PR #171)
  • WIT VPP export limitation controls (30200/30201 registers, PR #175)
  • WIT VPP V2.03 register definitions (TOU schedule, SOC limits, system time)
  • Grid power sensor improvement using power_to_user register (PR #170)
  • Register scan now includes holding registers in CSV output
  • New get_register_data service for programmatic register reads

What's New in v0.4.9:

1. 🔋 Fixed Battery Power Sign for VPP Protocol Registers

Problem: VPP protocol inverters (WIT, SPH V2.01) showing inverted battery power signs:

  • Battery charging (power should be positive) showed negative values
  • Battery discharging (power should be negative) showed positive values
  • Caused confusion in energy monitoring and automation

Root Cause:

  • VPP protocol stores battery power in registers 1013-1014 in swapped order
  • Register 1013: Low word (W)
  • Register 1014: High word (kW)
  • Integration was reading them as 1014+1013 (reversed), causing sign inversion

The Fix:

  • Registers 1013-1014 now read in correct order for VPP protocol profiles
  • Battery power signs now match physical behavior:
    • Positive = Charging (power going INTO battery)
    • Negative = Discharging (power coming OUT of battery)
  • Affects: WIT, SPH V2.01, and other VPP protocol inverters

Impact:

  • ✅ Battery power values now show correct sign
  • ✅ Automation triggers work as expected
  • ✅ Energy flow visualization accurate

2. 🔋 Added Missing Registers to SPH V2.01 Profiles (Issue #176)

Added to SPH V2.01:

  • Battery registers: SOC, voltage, current, power, temperature, discharge limits
  • Energy registers: Battery charge/discharge energy (today & total)
  • Complete battery monitoring for SPH inverters using VPP protocol

Impact:

  • ✅ SPH V2.01 users now have full battery monitoring
  • ✅ Battery charge/discharge energy tracking available
  • ✅ Complete parity with SPH TL3 legacy profile features

3. 🔧 Fixed Unique ID Collision for Multiple Inverters (Issue #179)

Problem: Multiple inverters on same IP (different ports) could not be configured:

  • Common with Modbus proxy/gateway setups
  • Second inverter rejected: "This inverter is already configured"

Root Cause:

  • TCP unique ID format was: {host}_{slave_id} (ignored port number)
  • Multiple inverters on same IP with different ports generated identical unique IDs

The Fix:

  • Changed TCP unique ID format to: {host}:{port}_{slave_id}
  • Example: 192.168.168.4:5021_1 vs 192.168.168.4:5022_1

Impact:

  • ✅ Multiple inverters on same IP with different ports now supported
  • ✅ Modbus proxy/gateway setups work correctly
  • ✅ Still prevents true duplicates (same IP+port+slave_id)

4. 🔧 Fixed SPH TL3 Energy Today (Issue #172)

Problem: SPH TL3 "Energy Today" showing AC output instead of true PV production:

  • DC-coupled battery charging excluded from total
  • Reported values significantly lower than actual solar production

The Fix:

  • Added per-MPPT PV energy registers (59-60, 63-64, 91-92) to SPH TL3 profile
  • Energy Today now calculated as: PV1 + PV2 (true solar production)
  • Same fix previously applied to WIT profile in v0.4.7

Impact:

  • ✅ Energy Today shows accurate total PV production
  • ✅ Values include DC-coupled battery charging
  • ✅ Consistent with WIT behavior

5. ✨ Multi-Register Write Support (PR #168)

Added: Ability to write multiple registers in a single Modbus transaction

  • New write_multiple_registers method in GrowattModbus class
  • Improved error reporting with detailed Modbus exception handling
  • Atomic multi-register writes for complex settings

Use Cases:

  • Setting TOU schedules (multiple time/power registers)
  • Batch configuration updates
  • Advanced inverter programming

6. 🎯 WIT VPP Battery Control Enhancements (PR #171)

Added:

  • WIT VPP battery control entities (charge/discharge power, duration)
  • Service handlers for programmatic battery control
  • Remote control enable/disable functionality
  • Integration with VPP protocol time-limited overrides

New Entities:

  • Remote Power Control Enable (register 30407)
  • Remote Charging Time (register 30408, duration in minutes)
  • Remote Charge/Discharge Power (register 30409, -100% to +100%)

7. 🎯 WIT VPP Export Limitation (PR #175)

Added:

  • VPP export limitation control registers (30200/30201)
  • Enable/disable export limiting
  • Set maximum export power to grid

Use Cases:

  • Comply with grid connection agreements
  • Prevent export during peak pricing
  • Dynamic export control based on conditions

8. 📊 WIT VPP V2.03 Register Additions (PR #169)

Added:

  • TOU (Time of Use) schedule registers
  • SOC (State of Charge) limit registers
  • System time registers
  • Enhanced VPP protocol support

9. 🔌 Grid Power Sensor Improvement (PR #170)

Changed: Grid power calculation now uses power_to_user register

  • More accurate grid import/export measurements
  • Better handling of CT clamp configurations
  • Improved power flow calculations

10. 🛠️ Enhanced Services and Diagnostics

Added:

  • get_register_data service for programmatic register reads
  • Holding registers now included in register scan CSV output
  • Better integration with automation and scripts

Migration Notes:

No action required - This is a bug fix and enhancement release.

For VPP Protocol Users (WIT, SPH V2.01):

  • Battery power signs will flip after upgrade (this is the fix - values are now correct)
  • Positive = Charging, Negative = Discharging
  • Update any automations that relied on the incorrect sign behavior

For SPH TL3 Users:

  • Energy Today values will increase (now showing true PV production)
  • Dashboard graphs may show a step change (expected - previous values were too low)

For SPH V2.01 Users:

  • Battery sensors will now appear after upgrade
  • Full battery monitoring now available

For Multi-Inverter Setups (Issue #179):

  • If you couldn't add a second inverter on same IP, try adding it again after upgrade
  • Both inverters will now configure successfully

For WIT Users:

  • New battery control and export limitation features available
  • See PR documentation for usage examples
  • Rate limiting (30s cooldown) applies to control writes

Files Changed:

Core functionality:

  • custom_components/growatt_modbus/growatt_modbus.py - Battery power sign fix, multi-register write support, enhanced services
  • custom_components/growatt_modbus/config_flow.py - Updated TCP unique_id format
  • custom_components/growatt_modbus/services.yaml - Added get_register_data service
  • custom_components/growatt_modbus/select.py - VPP export limitation
  • custom_components/growatt_modbus/diagnostic.py - Enhanced register scanning

Profile updates:

  • custom_components/growatt_modbus/profiles/sph_tl3.py - Added per-MPPT energy registers
  • custom_components/growatt_modbus/profiles/sph_v201.py - Added battery and energy registers
  • custom_components/growatt_modbus/profiles/wit.py - VPP control registers, export limitation

Version bump:

  • custom_components/growatt_modbus/manifest.json - Version 0.4.9
  • README.md - Version badge updated to 0.4.9
  • RELEASENOTES.md - Updated with v0.4.9 changes

Release Notes - v0.4.9b4 (Pre-Release)

🔧 Bug Fix - Multiple Inverters on Same IP

Fixed (Issue #179):

  • Multiple inverters on the same IP address (different ports) could not be configured
  • Integration rejected second inverter with "This inverter is already configured"
  • Common scenario with Modbus proxies/gateways exposing multiple inverters

What's Fixed in v0.4.9b4:

🔧 Fixed Unique ID Collision for Same-IP Multi-Inverter Setups (Issue #179)

Problem: Users with multiple inverters behind a Modbus proxy or gateway (same IP, different ports) could only configure one inverter. The second would fail with "This inverter is already configured."

Root Cause:

  • TCP unique ID format was: {host}_{slave_id}
  • Ignored the port number completely
  • Multiple inverters on same IP with different ports generated identical unique IDs

User Case (Issue #179):

  • Setup: 2 inverters → Waveshare → evcc → ModbusProxy
  • SPH 10k TL3 BH-UP: 192.168.168.4:5021 (slave 1)
  • MOD 10k TL3-XH: 192.168.168.4:5022 (slave 1)
  • Both generated unique_id: 192.168.168.4_1COLLISION!
  • Only first inverter could be added

The Fix:

Changed TCP unique ID format to include port number:

  • Old format: {host}_{slave_id} (e.g., 192.168.168.4_1)
  • New format: {host}:{port}_{slave_id} (e.g., 192.168.168.4:5021_1)

Impact:

  • ✅ Multiple inverters on same IP with different ports now supported
  • ✅ Common Modbus proxy/gateway setups now work correctly
  • ✅ Still prevents true duplicates (same IP+port+slave_id)
  • ✅ Serial connections unchanged

Example - Now Works:

Configuration:
  SPH 10k TL3:  192.168.168.4:5021 slave_id=1 → unique_id: 192.168.168.4:5021_1 ✅
  MOD 10k TL3:  192.168.168.4:5022 slave_id=1 → unique_id: 192.168.168.4:5022_1 ✅

Still Blocks Duplicates:
  First:   192.168.168.4:502 slave_id=1 → unique_id: 192.168.168.4:502_1 ✅ (allowed)
  Second:  192.168.168.4:502 slave_id=1 → unique_id: 192.168.168.4:502_1 ❌ (blocked - true duplicate)

Migration Notes:

No action required for existing single-inverter setups - unique IDs will update automatically.

For Multi-Inverter Setups (Issue #179):

  • If you previously couldn't add a second inverter on the same IP:
    1. Upgrade to v0.4.9b4
    2. Try adding the second inverter again
    3. Both inverters will now configure successfully

Technical Note:

  • Existing integrations will get new unique IDs on next restart
  • Home Assistant handles unique ID changes automatically
  • No need to remove/re-add existing integrations

Files Changed:

  • custom_components/growatt_modbus/config_flow.py - Updated TCP unique_id format to include port
  • custom_components/growatt_modbus/manifest.json - Version bump to 0.4.9b4
  • README.md - Version badge updated to 0.4.9b4
  • RELEASENOTES.md - Updated with v0.4.9b4 changes

Release Notes - v0.4.9b3 (Pre-Release)

🔧 Bug Fix - SPH TL3 Energy Today Incorrect Values

Fixed (Issue #172):

  • SPH TL3 "Energy Today" sensor showing AC output energy instead of true PV solar production
  • On hybrid inverters with batteries, DC-coupled battery charging was excluded from the total

What's Fixed in v0.4.9b3:

🔧 Fixed SPH TL3 Energy Today Calculation (Issue #172)

Problem: SPH TL3 users reported "Energy Today" showing significantly lower values than actual solar production. For example, a user producing ~8.1 kWh saw only 1.5-2.6 kWh reported.

Root Cause:

  • Registers 53-54 (energy_today) on SPH TL3 measure total AC output energy (what goes to grid/loads)
  • On hybrid inverters with batteries, energy that goes directly from PV to battery via DC coupling bypasses the AC side and is NOT counted in registers 53-54
  • This means the "Energy Today" sensor was underreporting by the amount of DC-coupled battery charging

User Case:

  • SPH TL3 inverter with battery
  • Register 54 = 15 → 1.5 kWh (AC output only)
  • Registers 60 (PV1) + 64 (PV2) = actual total PV production (~8.1 kWh)
  • Difference = energy going directly to battery via DC coupling

The Fix:

  1. Added Per-MPPT PV Energy Registers to SPH TL3 Profile:

    • 59-60: pv1_energy_today (PV string 1 DC energy production)
    • 63-64: pv2_energy_today (PV string 2 DC energy production)
    • 91-92: pv_energy_total (lifetime total PV energy from all MPPTs)
  2. Automatic Calculation:

    • Existing code already sums PV1 + PV2 when per-MPPT registers are available
    • energy_today now calculated as: PV1 + PV2 (true solar production)
    • Same approach already working correctly for WIT profile (Issue #146 fix in v0.4.7)

Impact:

  • Energy Today now shows accurate total PV production (DC input from solar panels)
  • Values include energy going to battery via DC coupling (previously excluded)
  • Energy Total (lifetime) now uses PV energy total register for accuracy
  • Other inverter profiles unaffected (backwards compatible)

Example - Before vs After:

Before (v0.4.9b1):
  Energy Today: 1.5 kWh  (AC output only, missing DC battery charging)

After (v0.4.9b3):
  Energy Today: 8.1 kWh  (PV1 + PV2 = true solar production)

Migration Notes:

No action required - Fix is automatic after upgrade.

For SPH TL3 Users:

  • "Energy Today" will now show higher (correct) values that include DC battery charging
  • Dashboard energy graphs may show a one-time step change after upgrade - this is expected
  • Previous values excluded DC-coupled battery charging (incorrect), new values are PV-only production (correct)

Files Changed:

  • custom_components/growatt_modbus/profiles/sph_tl3.py - Added per-MPPT PV energy registers (59-60, 63-64, 91-92)
  • custom_components/growatt_modbus/manifest.json - Version bump to 0.4.9b3
  • README.md - Version badge updated to 0.4.9b3
  • RELEASENOTES.md - Updated with v0.4.9b3 changes

Release Notes - v0.4.8

🔧 Bug Fix - MIC-1000TL-X Auto-Detection

Fixed (Issue #130):

  • MIC-1000TL-X inverters incorrectly auto-detected as MIN series
  • Manual MIC profile selection showed incorrect/missing values

What's Fixed in v0.4.8:

🔍 Improved MIC vs MIN Detection (Issue #130)

Problem:

  • DTC code 5200 is shared by both MIC and MIN inverter series
  • Previous logic tested for 3000+ register range to distinguish models
  • Some MIC-1000TL-X inverters use MIN register layout (hybrid design) but are physically MIC hardware
  • This caused incorrect auto-detection and wrong sensor values

Root Cause:

  • MIC-1000TL-X (2500-6000W range) can use either:
    • Standard MIC layout: 0-179 registers only
    • Hybrid layout: 0-124 + 3000-3124 (MIN addressing) BUT with MIC features
  • Previous detection tested register 3003 (MIN PV1 voltage)
  • If found → assumed MIN series ❌
  • If not found → assumed MIC series ✅

User Case:

  • MIC-1000TL-X with firmware "PV 1000"
  • Has data in BOTH 0-124 AND 3000-3124 ranges (hybrid layout)
  • Previous detection saw 3000+ range → incorrectly selected MIN profile
  • MIN profile missing MIC-specific per-MPPT energy registers (59-62)
  • Result: Wrong/missing sensor values

The Fix:

  1. Hardware-Level Detection:

    • MIC inverters have per-MPPT energy tracking capability (registers 59-62)
    • MIN inverters do NOT have these registers (not a firmware feature - hardware difference)
    • Now test registers 59-62 FIRST before checking register range
  2. New Detection Logic for DTC 5200:

    Step 1: Read registers 59-62 (PV1/PV2 per-MPPT energy)
    
    Step 2: Validate if values are plausible energy data:
            - MIC hardware: registers contain valid energy values (high word 0-100)
            - MIN hardware: registers return garbage/system values (e.g., 5200 = DTC code)
            - Check: high word < 100 (rejects invalid data like DTC codes)
    
    Step 3: If valid energy data found in registers 59-62:
            → MIC hardware detected
            → Check if uses MIN layout (3000+ range)
            → If yes: Use new MIC_2500_6000TL_X_MIN_RANGE profile
            → If no: Use standard MIC_600_3300TL_X_V201 profile
    
    Step 4: If registers 59-62 empty or invalid:
            → MIN hardware (no per-MPPT capability or garbage data)
            → Use MIN_3000_6000TL_X_V201 profile
    
  3. New MIC Profile Created:

    • Profile: MIC_2500_6000TL_X_MIN_RANGE
    • Supports hybrid MIC inverters using MIN register addressing
    • Combines:
      • MIN 0-124 register range (basic data)
      • MIN 3000-3124 register range (AC power, energy)
      • MIC per-MPPT registers 59-62 (PV1/PV2 energy tracking)
    • Provides complete sensor coverage for these hybrid models

Impact:

  • ✅ MIC-1000TL-X correctly auto-detected regardless of register layout
  • ✅ All sensors show correct values
  • ✅ Per-MPPT energy tracking available for MIC users
  • ✅ MIN detection unaffected (backwards compatible)
  • ✅ Reliable hardware-level differentiation (not just register addressing)

Example - Before vs After:

Before (v0.4.7):
  Auto-Detection: MIN 3000-6000TL-X ❌ (wrong - saw 3000+ range)
  AC Power: 1127 W ✅ (worked from 3000+ range)
  Energy Today: 0.1 kWh ❌ (wrong - MIN profile missing PV1/PV2 registers)
  PV1 Energy: Not available ❌ (MIN profile doesn't define register 59-60)

After (v0.4.8):
  Auto-Detection: MIC 2500-6000TL-X (MIN range) ✅ (correct - saw registers 59-62)
  AC Power: 1127 W ✅ (from 3000+ range)
  Energy Today: 0.1 kWh ✅ (correct - using per-MPPT registers)
  PV1 Energy: 0.1 kWh ✅ (now available from register 59-60)
  PV2 Energy: 44927.0 kWh ✅ (now available from register 61-62)

Technical Details:

Register Scan Analysis:

MIC-1000TL-X Hybrid Layout (verified):
  Register 11-12: 0 (MIC AC power location - empty)
  Register 35-36: 1127 (output power - populated)
  Register 59-60: 1/1 (PV1 energy - VALID energy data ✅)
  Register 61-62: 44927/0 (PV2 energy - VALID energy data ✅)
  Register 3028-3029: 1127 (MIN AC power location - populated)
  Register 3049-3052: energy values (MIN location - populated)

MIN 3000-6000TL-X (verified):
  Register 59: 5200 (garbage/DTC code - INVALID for energy ❌)
  Register 59-62: Returns system values, not energy data
  → Detection rejects high word >= 100 as garbage

Validation Logic:

  • Energy registers use 32-bit pairs (high word, low word)
  • Valid daily energy: 0-50 kWh → high word typically 0-1
  • Valid lifetime energy: 10,000 kWh → high word ~1-2
  • Threshold: high word must be < 100 to be valid energy
  • MIN garbage values (5200, DTC codes, etc.) correctly rejected

Key Insight: Registers 59-62 differentiate MIC/MIN at hardware level. MIN may respond to these registers but returns garbage/system values, not energy data.


Migration Notes:

No action required - Auto-detection improvement only.

For Affected MIC-1000TL-X Users (Issue #130):

  • If previously manually selected MIN profile as workaround:
    1. Remove integration
    2. Re-add integration with auto-detection
    3. Inverter will now correctly detect as MIC
    4. All sensors (including per-MPPT energy) will appear

Detection Changes:

  • MIC inverters with hybrid layout now correctly identified
  • All existing MIC and MIN inverters unaffected
  • More robust detection using hardware capabilities instead of register addressing

Release Notes - v0.4.7

🐛 Bug Fix + 📊 Diagnostic Enhancement

Fixed (Issue #146):

  • WIT "Energy Today" sensor showing incorrect values (total system output instead of PV-only production)
  • WIT "Energy Total" sensor not reflecting actual solar panel production

Enhanced:

  • Register scan now includes firmware version in metadata output

What's Fixed in v0.4.7:

1. 🔧 Fixed WIT PV Energy Calculation (Issue #146)

Problem: WIT users reported "Energy Today" sensor increasing at night when no solar production occurring.

Root Cause:

  • Registers 53-56 (energy_today/total) track total system AC output (PV + battery discharge combined)
  • Not suitable for tracking solar production on hybrid inverters with batteries
  • Values increase whenever battery powers loads, even at night

User Report:

  • Register 56 showed 6.2 kWh (wrong - total system output)
  • Register 60 (PV1): 4.8 kWh ✅
  • Register 64 (PV2): 2.7 kWh ✅
  • Actual PV production: 4.8 + 2.7 = 7.5 kWh

The Fix:

  1. Added Missing Registers to WIT Profile:

    • 59-60: PV1 Energy Today (per-MPPT tracking)
    • 63-64: PV2 Energy Today (per-MPPT tracking)
    • 91-92: PV Energy Total (lifetime DC input from all MPPTs)
  2. Added Dataclass Fields:

    • pv1_energy_today - PV1 MPPT daily production
    • pv2_energy_today - PV2 MPPT daily production
    • pv_energy_total - Lifetime PV production
  3. Changed Energy Calculation for WIT:

    • energy_today now calculated as: PV1 + PV2 (true solar production)
    • energy_total now uses register 92 (total PV lifetime energy)
    • Fallback to original registers for non-WIT inverters (backwards compatible)

Impact:

  • ✅ WIT "Energy Today" now shows accurate solar production (not total system output)
  • ✅ Values only increase during daylight when panels are producing
  • ✅ Correctly tracks DC input from solar panels only
  • ✅ Other inverter series unaffected (backwards compatible)

Example - Before vs After:

Before (v0.4.6):
  Energy Today: 6.2 kWh  ❌ (total system including battery)

After (v0.4.7):
  Energy Today: 7.5 kWh  ✅ (PV1 4.8 + PV2 2.7 = actual solar)

2. 📊 Register Scan Enhancement

Added: Firmware version now included in register scan metadata output.

How it Works:

  • Reads holding registers 9-11 (firmware version, ASCII encoded)
  • Decodes to human-readable version string
  • Displays in both CSV metadata and notification message

Example Output:

DETECTION ANALYSIS
Detected Model: WIT 4-15kW Hybrid
Confidence: Very High
DTC Code: 10046
Protocol Version: V2.01
Firmware: GH1.0     <-- NEW
Suggested Profile: WIT_4000_15000TL3

Impact:

  • ✅ Easier troubleshooting - firmware version visible in scans
  • ✅ Helps identify firmware-specific behaviors
  • ✅ No additional user action required - automatic extraction

Migration Notes:

No action required - This is a bug fix and enhancement release.

For WIT Users:

  • "Energy Today" and "Energy Total" sensors will now show correct PV production values
  • IMPORTANT: Values may differ from v0.4.6 - this is expected and correct
  • Previous values included battery discharge (wrong), new values are PV-only (correct)
  • Dashboard energy graphs may show a one-time step change after upgrade

For All Users:

  • Next register scan will include firmware version automatically
  • No changes needed to existing scans

Files Changed:

  • custom_components/growatt_modbus/profiles/wit.py - Added PV energy registers (59-60, 63-64, 91-92) with descriptions
  • custom_components/growatt_modbus/growatt_modbus.py - Added PV energy dataclass fields + reading code + smart calculation logic
  • custom_components/growatt_modbus/diagnostic.py - Added firmware version reading and display
  • custom_components/growatt_modbus/manifest.json - Version bump to 0.4.7
  • README.md - Version badge updated to 0.4.7
  • RELEASENOTES.md - Updated with v0.4.7 changes

Release Notes - v0.4.6

🐛 Bug Fixes + 🎯 WIT Control Stability Improvements

Fixed (Issue #163):

  • SPF AC Charge Energy Today/Total sensors showing 0.00 (should show same values as Battery Charge sensors)
  • SPF AC Discharge Energy Today/Total sensors showing 0.00 (registers 64-67)
  • Noisy WARNING log message for SPF users: "load_energy_today_low register not found"

Improved (Issue #143):

  • WIT control stability - prevent oscillation and unstable battery behavior
  • WIT control model clarified - VPP protocol vs Legacy protocol differences
  • Rate limiting added to prevent rapid control changes
  • Control conflict detection for TOU vs remote control scenarios

What's Fixed in v0.4.6:

1. 🔧 Fixed SPF AC Charge/Discharge Energy Sensors

Root Cause: SPF uses different register names than WIT for the same energy measurements, causing "AC Charge/Discharge Energy" sensors to show 0.00 even though the data exists.

Register Name Differences:

  • WIT: Uses ac_charge_energy_* and ac_discharge_energy_* register names
  • SPF: Uses charge_energy_* (56-59) and ac_discharge_energy_* (64-67) register names
  • Same data, different naming convention

Affected sensors (now fixed):

  • ac_charge_energy_today - Now populated from SPF's charge_energy_today (registers 56-57)
  • ac_charge_energy_total - Now populated from SPF's charge_energy_total (registers 58-59)
  • ac_discharge_energy_today - Now reads from registers 64-65
  • ac_discharge_energy_total - Now reads from registers 66-67

The Fix:

  1. AC Charge Energy: SPF now populates BOTH charge_energy_* AND ac_charge_energy_* fields from the same registers (56-59)
  2. AC Discharge Energy: Added missing register reading code for registers 64-67
  3. WIT compatibility: WIT-specific register names still work for WIT inverters

Impact:

  • ✅ SPF users will now see actual values in ALL "AC Charge/Discharge Energy" sensors
  • ✅ "AC Charge Energy" sensors will match "Battery Charge" sensors (same data source)
  • ✅ "AC Discharge Energy" sensors will show battery → load energy flow
  • ✅ Complete energy tracking for SPF 6000 ES Plus and similar models

What You'll See After Upgrade (SPF users):

  • "Battery Charge Today" = 0.80 kWh ✅ (working before)
  • "AC Charge Energy Today" = 0.80 kWh ✅ (NOW FIXED - was 0.00)
  • "Battery Charge Total" = 446.90 kWh ✅ (working before)
  • "AC Charge Energy Total" = 446.90 kWh ✅ (NOW FIXED - was 0.00)
  • "AC Discharge Energy Today" = actual value ✅ (NOW FIXED - was 0.00)
  • "AC Discharge Energy Total" = actual value ✅ (NOW FIXED - was 0.00)

Note: Both "Battery Charge" and "AC Charge Energy" sensors track the same thing (grid/generator charging your battery) and will show identical values. This is normal - they're just different sensor names for the same SPF register data.

2. 🔇 Reduced Log Noise for Off-Grid Inverters

Issue: SPF users (and other off-grid models) saw constant WARNING messages in Home Assistant logs:

[SPF 3000-6000 ES PLUS@/dev/ttyACM0] load_energy_today_low register not found Root Cause: The load_energy_today register is specific to grid-tied inverters (SPH/MIN/MID/MAX) that track energy consumed from grid by loads. Off-grid inverters like SPF don't have this register because they use different energy tracking:

  • ac_discharge_energy_* - Battery → loads via inverter
  • op_discharge_energy_* - Operational discharge energy

The code was logging this as a WARNING even though it's expected and harmless for off-grid models.

The Fix: Changed log level from WARNING to DEBUG with clarifying message: "register not found (expected for off-grid models like SPF)"

Impact:

  • ✅ SPF users will no longer see noisy warnings in logs
  • ✅ Debug logging still available if needed for troubleshooting
  • ✅ No functional changes - purely cosmetic log improvement

3. 🎯 WIT Control Stability Improvements (Issue #143)

Problem: WIT users experiencing power oscillation, charge/discharge looping, and unstable control behavior when using battery management features.

Root Cause: WIT inverters use VPP (Virtual Power Plant) protocol with fundamentally different control model:

  • WIT: Time-limited overrides (NOT persistent mode changes like SPH/SPF)
  • Register 30476 (priority_mode) is READ-ONLY on WIT - shows TOU default, cannot be changed via Modbus
  • Proper control requires VPP remote registers (30407-30409) with duration-based commands
  • Rapid control changes cause oscillation and conflicts with TOU schedules

The Fixes:

  1. Register 30476 Marked Read-Only

    • WIT profile now correctly marks priority_mode (30476) as 'access': 'R'
    • Prevents users from trying to write to read-only register
    • Description updated to clarify VPP control model
    • Users guided to use proper VPP remote control instead
  2. 30-Second Rate Limiting

    • All WIT control writes now have 30-second cooldown
    • Prevents rapid automation loops that cause oscillation
    • Applies to registers: 201, 202, 203, 30100, 30407, 30408, 30409
    • Warning logged if write blocked: "Rate limit: WIT control writes must be 30s apart"
    • Gives inverter time to respond and stabilize
  3. Control Conflict Detection

    • Detects multiple VPP remote controls active simultaneously
    • Warns when TOU schedule conflicts with remote control
    • Logs warnings to Home Assistant logs
    • Helps users identify problematic automation patterns
  4. Comprehensive WIT Control Guide

    • New documentation: docs/WIT_CONTROL_GUIDE.md
    • Explains VPP vs Legacy protocol differences
    • Shows proper WIT control patterns with examples
    • Documents why register 30476 is read-only
    • Provides automation templates for stable control
    • Troubleshooting guide for common issues

Impact:

  • ✅ WIT users can now implement stable battery control
  • ✅ Oscillation and looping behavior prevented
  • ✅ Clear guidance on proper VPP remote control usage
  • ✅ Automatic conflict detection helps debug issues
  • ✅ Rate limiting prevents automation mistakes

WIT Control Registers (Rate Limited):

  • 201: Active Power Rate (Legacy VPP)
  • 202: Work Mode (Legacy VPP)
  • 203: Export Limit (W)
  • 30100: Control Authority (VPP master enable)
  • 30407: Remote Power Control Enable
  • 30408: Remote Charging Time (duration in minutes)
  • 30409: Remote Charge/Discharge Power (-100% to +100%)

For WIT Users:

  • Read the guide: See docs/WIT_CONTROL_GUIDE.md for proper control patterns
  • Use VPP remote control: Don't try to write to register 30476
  • Set durations: All overrides should specify time duration (register 30408)
  • Wait 30s between changes: Rate limiting is intentional to prevent oscillation
  • Check for conflicts: Monitor logs for TOU vs remote control warnings

Migration Notes:

No action required - This is a bug fix and improvement release. Simply upgrade and:

  • SPF AC Charge/Discharge Energy sensors will show correct values
  • Log warnings for missing load_energy_today register will disappear
  • WIT control writes will have automatic rate limiting

For SPF users:

  • All four AC Charge/Discharge Energy sensors will now work
  • "AC Charge Energy" sensors will show identical values to "Battery Charge" sensors (expected behavior)
  • Log noise from missing grid-tied registers eliminated

For WIT users:

  • IMPORTANT: Read docs/WIT_CONTROL_GUIDE.md if you use battery control features
  • Control writes now have 30s cooldown (prevents oscillation - this is intentional)
  • Register 30476 (priority_mode) is now correctly marked read-only
  • If you have automations that write to WIT controls rapidly, they may need adjustment
  • Check logs for rate limit warnings and control conflict warnings

Debug logging setup (optional, for troubleshooting):

logger:
  default: info
  logs:
    custom_components.growatt_modbus: debug

Files Changed:

  • custom_components/growatt_modbus/growatt_modbus.py - Added AC charge/discharge energy register mapping for SPF + reduced log noise + WIT rate limiting + conflict detection
  • custom_components/growatt_modbus/profiles/wit.py - Marked priority_mode as read-only + added VPP control model documentation
  • docs/WIT_CONTROL_GUIDE.md - NEW: Comprehensive WIT control guide with examples and troubleshooting
  • custom_components/growatt_modbus/manifest.json - Version bump to 0.4.6
  • README.md - Version badge updated to 0.4.6
  • RELEASENOTES.md - Updated with v0.4.6 changes

Release Notes - v0.4.5

🔥 CRITICAL Bug Fix: Serial Connection File Descriptor Leak

Fixed:

  • CRITICAL: Serial connection file descriptor leak causing permanent integration failure after overnight offline periods

What's Fixed in v0.4.5:

1. 🔥 CRITICAL: Fixed Serial Connection File Descriptor Leak

Root Cause: When using USB-RS485 adapters (serial connection), failed connection attempts during offline periods (e.g., overnight when inverter is powered down) were not properly releasing the serial port file descriptor. Over hours of offline polling, hundreds of leaked file descriptors would accumulate until the system exhausted its limit.

Symptoms:

  • Integration works fine initially
  • Inverter goes offline (night time, powered down)
  • After several hours, integration stops working completely
  • Error in logs: OSError: [Errno 24] No file descriptors available
  • Integration never recovers even when inverter comes back online
  • Inverter is actually online (proven by Growatt cloud connectivity)
  • Only fix is restarting Home Assistant

Technical Details: The coordinator's _fetch_data() method had three critical flaws:

  1. No cleanup on failed connection - When connect() failed, disconnect() was never called to release the serial port
  2. No cleanup before retry - Each retry attempt would call connect() without first calling disconnect(), potentially creating multiple open file descriptors
  3. Silent exception handling - Bare except: pass blocks hid disconnect failures

Scenario Example:

  • Inverter offline 5pm-5am (12 hours)
  • Offline polling every 300s = ~144 poll attempts
  • Each attempt tries 3 connection retries = ~432 connection attempts
  • Each leaked file descriptor accumulates
  • At 5:12am when inverter wakes: errno 24 "No file descriptors available"
  • Integration permanently broken until HA restart

The Fix:

  1. Always disconnect before connect - Ensures clean state, prevents double-open
  2. Always disconnect after failed connect - Releases file descriptors even on failure
  3. Proper error logging - Replace bare except: pass with debug logging
  4. Connection state checking - Skip connect() if already connected (prevents double-open)

Files Changed:

  • coordinator.py:482-537 - Added disconnect calls before/after every connect attempt
  • growatt_modbus.py:330-350 - Added is_socket_open() check to prevent double-connect
  • growatt_modbus.py:351-364 - Enhanced disconnect error logging with critical error detection

Impact:

  • ALL Serial/USB-RS485 users (ALL inverter models): Integration now properly recovers from overnight offline periods
  • TCP users: Not affected by the bug, but benefits from cleaner connection management
  • All inverter series (MIN/MID/MAX/MOD/SPH/SPF/WIT/MIX/SPA): No more permanent failures when using serial connections
  • Logging: Better visibility into connection lifecycle and resource leak issues

Migration Notes:

  • No action required - fix is automatic
  • If you experienced this issue, upgrade to v0.4.5 and restart Home Assistant once
  • Monitor logs after upgrade - should see Disconnected successfully debug messages
  • If you see CRITICAL: File descriptor leak detected! in logs after upgrade, please report the issue

Files Changed:

  • custom_components/growatt_modbus/coordinator.py - Fixed file descriptor leak in _fetch_data()
  • custom_components/growatt_modbus/growatt_modbus.py - Enhanced connect/disconnect with leak prevention
  • custom_components/growatt_modbus/manifest.json - Version bump to 0.4.5
  • RELEASENOTES.md - Updated with v0.4.5 changes