Skip to content

Commit bc365cc

Browse files
author
Jenn Honkofsky
committed
Updated test references
1 parent ef88a37 commit bc365cc

File tree

1 file changed

+9
-9
lines changed

1 file changed

+9
-9
lines changed

input/PSD-UA.xml

Lines changed: 9 additions & 9 deletions
Original file line numberDiff line numberDiff line change
@@ -318,7 +318,7 @@
318318
interface.</h:li>
319319
</h:ul>
320320
<testlist>
321-
<test>
321+
<test id="APC_Test_1-UA">
322322
<h:b>UA Switching Methods</h:b><h:br/><h:br/>
323323
[Conditional: Perform this test if “switching can be initiated only through express user action” is selected
324324
in FDP_SWI_EXT.1.1 in the PSD PP]<h:br/><h:br/>
@@ -341,7 +341,7 @@
341341
</h:ol>
342342
</test>
343343

344-
<test>
344+
<test id="APC_Test_2-UA">
345345
<h:b>Positive and Negative Keyboard and Mouse Data Flow Rules Testing</h:b><h:br/><h:br/>
346346
This test verifies correct data flows of a UA device during different power states of the selected computer.
347347
<h:ol>
@@ -390,7 +390,7 @@
390390
</h:ol>
391391
</test>
392392

393-
<test>
393+
<test id="APC_Test_3-UA">
394394
<h:b>No Electrical Flow between Computer Interfaces</h:b><h:br/><h:br/>
395395
[Conditional: Perform this test if “switching can be initiated only through express user action” is selected
396396
in FDP_SWI_EXT.1.1 in the PSD PP]<h:br/><h:br/>
@@ -414,8 +414,8 @@
414414
</h:ol>
415415
</test>
416416

417-
<test>
418-
<h:b>No Flow between Computer Computers over Time</h:b><h:br/><h:br/>
417+
<test id="APC_Test_4-UA">
418+
<h:b>No Flow between Connected Computers over Time</h:b><h:br/><h:br/>
419419
This test verifies that the TOE does not send data to different computers connected to the same interface
420420
at different times. Repeat this test for each TOE UA computer port.<h:br/><h:br/>
421421
Note that instead of the session ID, the evaluator may substitute authentication element or other unique
@@ -994,7 +994,7 @@
994994
</Guidance>
995995
<CustomEA name="Isolation"/>
996996
<Tests>
997-
Testing for this component is performed as part of FDP_APC_EXT.1 test 2-UA.
997+
Testing for this component is performed as part of <xref to="APC_Test_2-UA"/>.
998998
</Tests>
999999
</aactivity>
10001000
</f-element>
@@ -1138,7 +1138,7 @@
11381138
</Guidance>
11391139
<CustomEA name="Isolation"/>
11401140
<Tests>
1141-
Testing for this component performed as part of FDP_APC_EXT.1 test 2‐UA.
1141+
Testing for this component performed as part of <xref to="APC_Test_2-UA"/>.
11421142
</Tests>
11431143
</aactivity>
11441144
</f-element>
@@ -1188,7 +1188,7 @@
11881188
user authentication device upon switching.
11891189
</CustomEA>
11901190
<Tests>
1191-
Testing for this component is performed as part of FDP_APC_EXT.1 test 2‐UA.
1191+
Testing for this component is performed as part of <xref to="APC_Test_2-UA"/>.
11921192
</Tests>
11931193
</aactivity>
11941194
</f-element>
@@ -1279,7 +1279,7 @@
12791279
the claimed iterations of FDP_PDC_EXT.2.<h:br/><h:br/>
12801280
Power events at a user authentication interface for one connected computer cannot impact power events
12811281
at an analog audio output interface for another connected computer and vice versa, as per
1282-
FDP_APC_EXT.1. This evaluation activity is tested in Test 3‐AO in the Supporting Document for Audio
1282+
FDP_APC_EXT.1. This evaluation activity is tested in FDP_APC_EXT.1:3 in the PP-Module for Audio
12831283
Output.<h:br/><h:br/>
12841284
Both PP‐Modules modify the Base‐PP SFR FDP_APC_EXT.1 in ways that are specific to their respective
12851285
peripheral types. The ST author should make two iterations of this SFR, FDP_APC_EXT.1/UA and

0 commit comments

Comments
 (0)