This document details the vessel's 230V Alternating Current (AC) distribution architecture, the Scheiber physical switch panels, the MasterVolt 2000W and Victron 375W inverters, and how their real-time states are decoded and published to Venus OS (Cerbo GX) and Node-RED.
The vessel has two independent AC distribution panels / branch circuits:
- House AC Distribution Panel: Powers general 230V domestic outlets, galley equipment, battery chargers, and onboard conveniences.
- Air Conditioning (A/C) AC Distribution Panel: Dedicated high-power circuit for the vessel's climate control systems.
- MasterVolt 2000W Inverter: High-power inverter dedicated to supplying the House AC distribution bus when off-grid and without the generator. It does not power the Air Conditioning panel.
- Victron Phoenix 375W Inverter: Standalone inverter dedicated to continuous Starlink power, connected directly via VE.Direct into Venus OS.
┌── [ Shore Power ] ──┐
├── [ Onboard Generator ] ──┤
│ ▼
│ ┌──────────────────────┐
├───────────────►│ A/C Switch Panel │──► Air Conditioning (230V)
│ │ (Off/Shore/Generator)│ [CAN: 0x02400B90 & 0x02040B90]
│ └──────────────────────┘
│
│ ┌──────────────────────┐
├───────────────►│ House Switch Panel │──► House Sockets / Appliances (230V)
│ │ (Off/Shore/Gen/Inv) │ [CAN: 0x02400B88 & 0x02040B88]
│ └──────────────────────┘
│ ▲
[MasterVolt 2000W Inverter] ────────────────┘ (Normally enabled fallback;
supplies House only when selected)
[Victron 375W Inverter] ──────────────────────────────────► Starlink (Independent / VE.Direct)
The physical Scheiber panel outputs applied feedback when source contactors change:
| Channel | CAN Frame ID | Byte Offset | Enum Values | Description |
|---|---|---|---|---|
| House Panel Applied Source | 0x02400B88 |
Byte 0 | 0x01 = OFF0x02 = SHORE0x04 = GENERATOR0x08 = INVERTER (Effective) |
Current AC source contactor applied to House distribution bus |
| A/C Panel Applied Source | 0x02400B90 |
Byte 0 | 0x01 = OFF0x02 = SHORE0x04 = GENERATOR |
Current AC source contactor applied to Air Conditioning bus |
The MasterVolt is normally left enabled as the House fallback, but it has a physical OFF switch. House applied-source feedback determines whether it is actually supplying the bus. The shared transition frame is context-gated:
| CAN Frame ID | Byte Offset | Value | Event & Meaning |
|---|---|---|---|
0x02140898 |
Byte 0 | 0x03 |
Ramp-up; accepted as MasterVolt enabled only when House is not on Shore/Generator |
0x02140898 |
Byte 0 | 0x02 |
Ramp-down; accepted as MasterVolt disabled only when House is not on Shore/Generator |
0x02060B88 |
Bytes 0..3 | 00 7C 7F FF → 00 7E 7F FF |
House AC transfer contactor status confirmation. |
| Measurement | CAN Frame ID | Bytes | Scaling | Rate | Range |
|---|---|---|---|---|---|
| House AC Line Voltage (Heartbeat) | 0x00000B88 |
Bytes 2..3 (BE) | uint16 Whole Volts |
Continuous 1 Hz | 0 – 250 V |
| A/C Line Voltage (Heartbeat) | 0x00000B90 |
Bytes 2..3 (BE) | uint16 Whole Volts |
Continuous 1 Hz | 0 – 250 V |
| House AC Extended Telemetry | 0x02040B88 |
Bytes 4..5 (BE) | uint16 Whole Volts |
Periodic / Event | 0 – 250 V |
| A/C Extended Telemetry | 0x02040B90 |
Bytes 4..5 (BE) | uint16 Whole Volts |
Periodic / Event | 0 – 250 V |
The integration exposes physical AC hardware as native Victron D-Bus device services:
com.victronenergy.inverter.scheiber_mastervolt(MasterVolt 2000W House Inverter • DeviceInstance 270):/State:9while the inverter is enabled/running,0when a context-valid OFF transition is observed/Mode:2(ON),4(OFF)/Ac/Out/L1/V: House voltage only while the inverter is actually supplying the House bus; unavailable while Shore or Generator is selected/Dc/0/Voltage: House battery supply voltage
com.victronenergy.grid.scheiber_shore(Shore Power Transfer • DeviceInstance 41):/Connected:1when Shore is applied to either panel with 80–300V line voltage,0in standby/Ac/L1/Voltage: Measured Shore AC line voltage
com.victronenergy.acsystem.scheiber_house(House source selector • DeviceInstance 42, receive-only):/Ac/NumberOfAcInputs:2/Ac/In/1/Type:3(Shore)/Ac/In/2/Type:2(Generator)/Ac/ActiveIn/ActiveInput:0(Shore),1(Generator), or240(neither external input)/Ac/In/1/L1/Vand/Ac/In/2/L1/V: measured House-bus voltage on the active external input/Scheiber/HousePanel*and/Scheiber/AcPanel*: both selectors' receive-only source and voltage diagnostics
com.victronenergy.inverter.ttyS7(Phoenix 12V 375VA • Starlink Inverter • DeviceInstance 279):- Dedicated VE.Direct inverter for Starlink connectivity
Under com.victronenergy.genset.scheiber on the Cerbo GX system bus:
| D-Bus Path | Type | Example Values | Purpose |
|---|---|---|---|
/Scheiber/HousePanelAppliedSource |
int |
1 (OFF), 2 (SHORE), 4 (GEN), 8 (INVERTER) |
Numeric source enum for House bus |
/Scheiber/HousePanelAppliedSourceText |
string |
"OFF", "SHORE", "GENERATOR", "INVERTER" |
Human-readable House source |
/Scheiber/AcPanelAppliedSource |
int |
1 (OFF), 2 (SHORE), 4 (GEN) |
Numeric source enum for A/C bus |
/Scheiber/AcPanelAppliedSourceText |
string |
"OFF", "SHORE", "GENERATOR" |
Human-readable A/C source |
/Scheiber/MastervoltInverterState |
int |
0 (OFF), 1 (ON) |
MasterVolt 2000W operating state |
/Scheiber/MastervoltInverterStateText |
string |
"OFF", "ON" |
MasterVolt 2000W operating text |
/Scheiber/MastervoltSupplyingHouse |
int |
0, 1 |
Whether the House selector is actually taking inverter power |
/Scheiber/MastervoltSupplyingHouseText |
string |
"NO", "YES" |
Human-readable House-supply role |
/Scheiber/HousePanelVoltage |
float |
230.0 V |
Measured House AC voltage |
/Scheiber/AcPanelVoltage |
float |
230.0 V |
Measured A/C AC voltage |
In Victron GUI-v2 (http://venus.local/gui-v2/), the AC topology is rendered dynamically:
- Shore / Generator Tiles: The House selector drives the standard Venus two-input topology. GUI-v2 labels input 1 as Shore, input 2 as Generator, highlights the selected external input, and reads its measured line voltage. The Generator card also shows the connected-genset state and voltage, for example
Running · 230 V. - MasterVolt Inverter Node: Reports inverting only while the inverter is actually feeding the House bus. Its enabled/standby fallback state does not override an applied Shore or Generator selection.
- Control Cards: Tapping Controls/Cards displays
Inverter (MasterVolt 2000W)andInverter (STARLINK INV)as dedicated standalone tiles.
The stock Overview has one system-level active AC-input model, so it cannot draw the House and A/C selector panels as two independent transfer diagrams. The House selector is authoritative for Overview; the A/C selector remains visible through the diagnostic D-Bus paths and the Node-RED AC routing view.
The flow (cerbo/node-red-ac-power-flow.json) monitors all D-Bus paths and maintains a live power routing matrix:
{
"summary": "House: INVERTER (230V) | A/C: OFF (0V) | Mastervolt 2000W: ON",
"house": {
"source": "INVERTER",
"voltage_v": 230,
"active": true
},
"air_conditioning": {
"source": "OFF",
"voltage_v": 0,
"active": false
},
"mastervolt_inverter": {
"state": "ON",
"inverting": true
}
}This flow is automatically installed, staged, and merged non-destructively by install.sh.