Scheiber native GX switch service — implementation and field handover

1. Purpose and current status

This document hands over the active Scheiber Multibloc V8 sailing-panel integration as a native Victron Venus OS switch device. It is based on the labelled CAN evidence and mappings in docs/control-panel-v8/.

The following has now been validated on the vessel:

  • the service installs and starts on a Cerbo GX;
  • all ten native switch controls render in the GX Switch pane;
  • physical panel changes propagate to GX;
  • active GX writes emit the expected momentary Scheiber key events;
  • feedback-gated state convergence works for the tested circuits;
  • reboot testing exposed unstable Linux canN enumeration for the USB adapter.

The remaining pump-specific validation item is a controlled bilge AUTO-triggered cycle to confirm that the known bilge-running input bits behave in AUTO exactly as they do during the already observed MANUAL tests.

2. Runtime architecture

Scheiber CAN network
       │
       ├── gs_usb / candleLight adapter
       │       └── Linux name varies by boot: can0, can1, can2, ...
       │
       ├── scheiber-gx
       │       ├── resolves physical USB-CAN identity
       │       ├── configures bitrate and restart-ms
       │       ├── publishes /run/scheiber-can-if
       │       └── genset / tanks / batteries
       │
       └── scheiber-switch
               ├── waits for /run/scheiber-can-if
               └── com.victronenergy.switch.scheiber

Files:

cerbo/bridge.py                     existing field-tested generator/telemetry process
cerbo/resolve_can_interface.py      stable USB identity -> current canN resolver
cerbo/scheiber_switch_protocol.py   pure CAN mapping, state model and command planner
cerbo/switch_service.py             D-Bus + SocketCAN switch runtime
cerbo/service/run                   main runit entrypoint and CAN owner
cerbo/service-switch/run            switch runit entrypoint
cerbo/install.sh                    transactional installer/updater
cerbo/uninstall.sh                  disables both services

The two Python services use independent raw CAN sockets and receive the same frames. The main service is deliberately the single owner of physical interface discovery and link configuration.

3. Stable CAN adapter identity

3.1 Field observation

After a Cerbo reboot, the USB adapter previously known as can2 appeared as can0. The same boot showed:

can0  driver=gs_usb
can1  driver=sun4i_can

The external adapter exposes a stable USB identity:

ID_VENDOR_ID=1d50
ID_MODEL_ID=606f
ID_SERIAL_SHORT=0025003C5457530220383638
ID_USB_DRIVER=gs_usb

The physical USB device path observed at that time was:

/sys/devices/platform/soc/1c14400.usb/usb3/3-1/3-1:1.0

The USB port path is useful diagnostic information, but the serial number is the preferred identity because port placement may change.

3.2 Resolution policy

CAN_IF=auto is the preferred configuration. At each main-service start, resolve_can_interface.py:

  1. enumerates CAN-like interfaces from /sys/class/net;
  2. keeps only gs_usb interfaces for automatic discovery;
  3. applies the exact configured USB serial when present;
  4. optionally verifies USB vendor and product IDs;
  5. accepts exactly one match;
  6. fails closed if zero or multiple devices match.

It never chooses the first canN entry.

Explicit CAN_IF=can0 remains supported for diagnostics or unusual hardware, but it is not stable across boot ordering.

After successful resolution and link setup, scheiber-gx atomically writes the current interface name to:

/run/scheiber-can-if

scheiber-switch waits for that file and verifies that the published interface is UP at the configured bitrate. It does not run a second, independent device selection algorithm.

3.3 Persisted configuration

/data/scheiber-gx/CAN_INTERFACE        auto or explicit interface selector
/data/scheiber-gx/CAN_BITRATE          normally 250000
/data/scheiber-gx/CAN_USB_SERIAL       stable adapter serial
/data/scheiber-gx/CAN_USB_VENDOR_ID    optional VID
/data/scheiber-gx/CAN_USB_PRODUCT_ID   optional PID

The runtime file under /run is intentionally not persistent; /run is reset at boot and therefore cannot retain a stale canN assignment.

4. Logical GX controls

GX channel UI Scheiber output(s) Key(s) Actual-running signal
Electronics Toggle 1 0x02
Deck Floodlight Toggle 2 0x05
Navigation Lights Toggle 3 0x03
Anchor Light OFF/AUTO/ON 4 0x06
Steaming Light Toggle 5 0x04
Port Bilge Pump OFF/AUTO/ON 6 AUTO + 7 MANUAL 0x08, 0x0C 0x02141808 bit 1
Starboard Bilge Pump OFF/AUTO/ON 8 AUTO + 9 MANUAL 0x09, 0x0D 0x02141808 bit 2
Fresh Water Pump OFF/ON 10 enable 0x0A 0x02141808 bit 0
Fridge Unit Toggle 11 0x0B
General Lighting Toggle 12 0x07

The native D-Bus service is:

com.victronenergy.switch.scheiber

Switch paths:

/SwitchableOutput/<channel>/State
/SwitchableOutput/<channel>/Auto             # Anchor and bilges
/SwitchableOutput/<channel>/Status
/SwitchableOutput/<channel>/Settings/...
/SwitchableOutput/<channel>/Scheiber/...

Read-only activity inputs:

/GenericInput/fresh_water_pump_running
/GenericInput/bilge_port_running
/GenericInput/bilge_starboard_running

5. State is authoritative; commands are requests

The physical panel key frame is:

CAN ID  0x04001808
press   00 00 00 01 (key | 0x80)
release 00 00 00 01 key

A press/release pair is a momentary key event, not an explicit ON or OFF command. Therefore every physical output begins UNKNOWN at process start.

The six paired state frames are:

0x02161808 outputs 1–2
0x02181808 outputs 3–4
0x021A1808 outputs 5–6
0x021C1808 outputs 7–8
0x021E1808 outputs 9–10
0x02201808 outputs 11–12

Slot 1 uses byte 2 bit 0 and slot 2 uses byte 6 bit 0. A command is rejected until its relevant physical state has synchronized.

Normal transaction:

D-Bus desired state
       │
       ├── actual UNKNOWN          → reject
       ├── actual already desired  → no CAN transmission
       └── actual differs
                │
                ├── one key press
                ├── approximately 150 ms
                ├── one key release
                └── wait for matching state frame
                         ├── match     → complete
                         └── 4 s       → OutputFault

There are no automatic key retries. Repeating an unconfirmed toggle could reverse the intended state.

Direct CMD_S_TOR output forcing is not used. This preserves distributed Scheiber logic, including the observed Steaming Light -> Navigation Lights interlock.

6. Bilge mode and activity semantics

Each bilge has separate Scheiber AUTO and MANUAL state bits:

OFF     AUTO=0  MANUAL=0
AUTO    AUTO=1  MANUAL=0
MANUAL  AUTO=1  MANUAL=1

AUTO=0, MANUAL=1 is unobserved and treated as invalid. Safe transitions are:

From To Key sequence
OFF AUTO AUTO
OFF MANUAL AUTO, then MANUAL
AUTO OFF AUTO
AUTO MANUAL MANUAL
MANUAL AUTO MANUAL
MANUAL OFF MANUAL, then AUTO

Each step waits for CAN confirmation before the next key event.

The GX three-state row has two simultaneous jobs:

  • Auto represents the selected Scheiber AUTO mode.
  • On represents manual force and also mirrors actual motor activity.

Expected visual states:

OFF + not running       Off
AUTO + not running      Auto
AUTO + running          Auto + On
MANUAL                  On

MANUAL keeps On selected because it commands continuous pumping. During AUTO, On follows the physical running bit. This mirrors the physical switchboard, where the ON LED illuminates while the pump is actually pumping.

An unexpected mode=OFF plus running=1 is deliberately visible and should be raised as an anomaly alarm.

7. Fresh-water pressure pump semantics

Output 10 means the pressure system is enabled. It does not mean the motor is currently turning:

output 10              pressure system enabled/disabled
0x02141808 bit 0       motor currently ACTIVE due to demand

The GX control is therefore simply:

OFF   pressure system disabled
ON    pressure system enabled; pressure switch controls motor demand

A separate activity card shows:

Motor: Standby
Motor: ACTIVE

There is no user-facing Auto mode for this circuit. Automation can still write the normal ON/OFF D-Bus state later, but the pressure switch remains the low-level automatic motor controller.

Only Anchor Light persists an automation-ownership preference for future sunrise/sunset Node-RED logic. Physical output state is never persisted.

8. Connection loss and restart behavior

The panel emits an ALIVE frame approximately once per second. If no recognized panel activity is seen for five seconds:

  • /Connected becomes 0;
  • any pending command fails;
  • physical output and running state return to UNKNOWN;
  • controls become disabled;
  • writes remain blocked until synchronization returns.

On reboot:

  1. the main runit service loads gs_usb;
  2. resolves the configured USB identity to the current canN;
  3. configures 250 kbit/s with restart-ms 100;
  4. brings the interface UP;
  5. writes /run/scheiber-can-if;
  6. starts the generator/telemetry bridge;
  7. the switch service consumes the same runtime interface name.

Diagnostics:

/data/scheiber-gx/bridge.log
/data/scheiber-gx/switch.log
/data/scheiber-gx/switch-status.json
/data/scheiber-gx/switch-settings.json
/run/scheiber-can-if

9. Installation/update

For a pinned branch or commit:

mkdir -p /data/scheiber-gx-installer
cd /data/scheiber-gx-installer

REF="<commit-sha>"
RAW_BASE="https://raw.githubusercontent.com/danielkope/scheiber-can-analysis-nmea2000/${REF}/cerbo"

curl -fL "${RAW_BASE}/install.sh" -o install.sh
chmod 755 install.sh

CAN_IF=auto \
CAN_USB_SERIAL=0025003C5457530220383638 \
CAN_USB_VENDOR_ID=1d50 \
CAN_USB_PRODUCT_ID=606f \
CAN_BITRATE=250000 \
SWITCH_TX_ENABLED=1 \
SWITCH_RTR_ENABLED=1 \
RAW_BASE="${RAW_BASE}" \
./install.sh

The installer can auto-enrol the serial if exactly one gs_usb interface exists and no serial is supplied. Explicit pinning is preferred for long-term clarity.

Verify:

cat /run/scheiber-can-if
ip -details -statistics link show "$(cat /run/scheiber-can-if)"
sv status /service/scheiber-gx /service/scheiber-switch

dbus -y com.victronenergy.switch.scheiber /Connected GetValue
dbus -y com.victronenergy.switch.scheiber \
  /Scheiber/SynchronizedOutputCount GetValue

Expected synchronized output count:

12

10. Remaining controlled field validation

Bilge AUTO activity

For one side at a time:

  1. place the bilge in AUTO;
  2. confirm Auto is selected and On is not selected while idle;
  3. safely trigger the float/automatic demand;
  4. capture 0x02141808;
  5. confirm the relevant running bit becomes 1;
  6. confirm GX displays Auto + On;
  7. let the pump stop;
  8. confirm the bit returns to 0 and GX returns to Auto only;
  9. save the annotated capture as immutable evidence.

Do not enable unattended bilge alarm automation until this test is recorded.

11. Node-RED follow-on

Node-RED must write D-Bus, not CAN. The switch service remains the only CAN command owner.

Anchor light

Mode OFF     light forced off; scheduling inactive
Mode AUTO    sunset -> ON; sunrise + 1 hour -> OFF
Mode ON      manual forced on

Use persisted absolute deadlines rather than memory-only delay nodes so Cerbo restarts do not reset maximum runtimes.

Fresh-water pump

Potential rules:

  • disable below a configured tank threshold;
  • disable when the vessel is unattended;
  • warn and optionally disable after abnormal continuous activity;
  • alarm when disabled but running feedback remains active.

11.4 Deployed Node-RED Automation Flows

The switch service integrates with automated flows on Node-RED (https://venus.local:1881/):

1. Automatic Sunset/Sunrise Anchor Light Controller (Anchor Light Auto)

Monitors vessel GPS position (com.victronenergy.gps), computes local sunrise/sunset, and controls the Anchor Light switch automatically when Auto mode is selected on D-Bus.

Anchor Light Auto Flow

2. Real-Time Bilge Alarms & Monitoring (Bilge Alarms & Monitor)

Listens to continuous pump motor telemetry (0x02141808) and mode registers (0x02140808), providing 2-minute run warnings, 5-minute critical alarms, and mode-OFF anomaly injection into Venus OS GUI notifications.

Do not automatically stop a long-running bilge. Long runtime can indicate water ingress and should escalate alarms while pumping continues.

Bilge Alarms and Monitor Flow

12. Rollback

Disable both services without deleting persistent data:

/data/scheiber-gx-installer/uninstall.sh

Disable only the switch service:

svc -d /service/scheiber-switch
rm -f /service/scheiber-switch

The generator/telemetry service can remain running independently.

13. Non-negotiable rules

  • Never assume OFF at startup.
  • Never establish a baseline by turning every circuit off.
  • Never flatten a bilge into a single boolean.
  • Never infer motor activity from mode when 0x02141808 is available.
  • Never automatically repeat an unconfirmed toggle command.
  • Never choose the first canN when USB identity is ambiguous.
  • Never use direct output forcing without separate evidence and safety review.
  • Preserve Scheiber interlocks and treat CAN state frames as authoritative.
  • Keep active-test captures immutable and document exact operator actions.