Details
Problem
I am performing a structural relaxation calculation for a CO/Rh(111) system using ABACUS.
The SCF calculation converges normally, but the structural relaxation does not converge. I have already increased relax_nmax to 400 steps, but the largest force remains significantly larger than the force threshold of 0.02 eV/Angstrom.
I noticed that the C and O atoms have relatively large forces in the z direction.
For example, near the end of the relaxation:
C1 Fz = -0.151966 eV/Angstrom
O1 Fz = 0.091577 eV/Angstrom
The k-point mesh is 8 × 6 × 1.
I would like to know whether this behavior is more likely caused by:
- insufficient k-point sampling,
- an unreasonable initial adsorption structure, or
- some other setting in the relaxation calculation.
The SCF calculations converge normally, but the relaxation does not.
I have attached the INPUT, STRU, and running_relax.log files for reference.
running_relax.log
STRU.txt
INPUT.txt
Task list for Issue attackers (only for developers)
Details
Problem
I am performing a structural relaxation calculation for a CO/Rh(111) system using ABACUS.
The SCF calculation converges normally, but the structural relaxation does not converge. I have already increased
relax_nmaxto 400 steps, but the largest force remains significantly larger than the force threshold of 0.02 eV/Angstrom.I noticed that the C and O atoms have relatively large forces in the z direction.
For example, near the end of the relaxation:
C1 Fz = -0.151966 eV/Angstrom
O1 Fz = 0.091577 eV/Angstrom
The k-point mesh is 8 × 6 × 1.
I would like to know whether this behavior is more likely caused by:
The SCF calculations converge normally, but the relaxation does not.
I have attached the
INPUT,STRU, andrunning_relax.logfiles for reference.running_relax.log
STRU.txt
INPUT.txt
Have you read FAQ on the online manual http://abacus.deepmodeling.com/en/latest/community/faq.html
Task list for Issue attackers (only for developers)