<?php
/*
* CLI worker (should be invoked once per minute)
*
* For every unit/slot whose fire_at has passed, send the captured payload
* to the AC unit then null out the slot.
*/
if (PHP_SAPI !== 'cli') {
fwrite(STDERR, "timer_worker.php must be run from the CLI\n");
exit(1);
}
require_once __DIR__ . '/daikin_client.php';
require_once __DIR__ . '/daikin_response_parser.php';
require_once __DIR__ . '/timer_store.php';
if (!timer_feature_enabled()) {
exit(0);
}
$now = time();
$fired = [];
timer_store_modify(function (&$all) use ($now, &$fired) {
foreach ($all as $unit_ip => $slots) {
foreach (['on', 'off'] as $slot) {
$entry = $slots[$slot] ?? null;
if ($entry === null) continue;
$fire_ts = strtotime($entry['fire_at'] ?? '');
if ($fire_ts === false || $fire_ts > $now) continue;
$payload = $entry['payload'] ?? null;
if (!is_array($payload) || empty($payload)) {
fwrite(STDERR, "[timer_worker] skipping $unit_ip/$slot: empty payload\n");
$all[$unit_ip][$slot] = null;
continue;
}
$fired[] = ['unit_ip' => $unit_ip, 'slot' => $slot, 'payload' => $payload];
$all[$unit_ip][$slot] = null;
}
}
});
foreach ($fired as $job) {
$when = date('c');
try {
$raw = daikin_post($job['unit_ip'], '/aircon/set_control_info', $job['payload']);
daikin_response_parse_expecting_ok($raw);
fwrite(STDOUT, "[$when] FIRED {$job['unit_ip']} {$job['slot']} -> $raw\n");
} catch (RuntimeException $e) {
fwrite(STDERR, "[$when] FAIL {$job['unit_ip']} {$job['slot']} -> {$e->getMessage()}\n");
}
}