ModbusRTU ESP32
Minimalistic example of server responding for multiple IDs. That is the server looks as multiple devices on bus.
(c)2022 Alexander Emelianov ([email protected])
https://github.com/emelianov/modbus-esp8266
This code is licensed under the BSD New License. See LICENSE.txt for more info.
*/
#include <ModbusRTU.h>
#define REGN 10
#define PRIMARY_ID 1
#define PRIMERT_VALUE 100
#define SECONDARY_ID 2
#define SECONDARY_VALUE 200
ModbusRTU mb;
Modbus::ResultCode cbRtuRaw(uint8_t* data, uint8_t len, void* custom) {
auto src = (Modbus::frame_arg_t*) custom; // <custom> argument contains some data on incoming packet
Serial.printf("RTU Slave: %d, Fn: %02X, len: %d, ", src->slaveId, data[0], len);
if (src->slaveId == SECONDARY_ID) // Check if incoming packet is addresses to server with ID <SECONDARY_ID>
return Modbus::EX_FORCE_PROCESS; // Instruct the library to force the packet processing
// It's required as otherwise packet will be not processed as not addressed
// to the server <PRIMARY_ID>
return Modbus::EX_PASSTHROUGH; // or process packet normally
}
uint16_t cbRead(TRegister* reg, uint16_t val) {
if (mb.eventSource() == SECONDARY_ID)
return SECONDARY_VALUE;
return val;
}
void setup() {
Serial.begin(115200);
Serial1.begin(9600);
mb.begin(&Serial1);
mb.slave(PRIMARY_ID); // Set Modbus to work as a server with ID <PRIMARY_ID>
mb.onRaw(cbRtuRaw); // Assign raw packet callback
mb.addHreg(REGN, PRIMARY_VALUE);
mb.onGet(cbReadHreg)
}
void loop() {
mb.task();
yield();
}