1 | 1 | from libecalc.domain.process.compressor.core.sampled import CompressorModelSampled |
2 | 2 | from libecalc.domain.process.compressor.core.train.simplified_train import ( |
3 | | - CompressorTrainSimplifiedKnownStages, |
4 | | - CompressorTrainSimplifiedUnknownStages, |
| 3 | + CompressorTrainSimplified, |
| 4 | + KnownStagesConfig, |
| 5 | + UnknownStagesConfig, |
5 | 6 | ) |
| 7 | +from libecalc.domain.process.compressor.core.train.simplified_train_builder import SimplifiedTrainBuilder |
6 | 8 | from libecalc.domain.process.compressor.core.train.single_speed_compressor_train_common_shaft import ( |
7 | 9 | SingleSpeedCompressorTrainCommonShaft, |
8 | 10 | ) |
@@ -51,25 +53,6 @@ def _create_variable_speed_compressor_train_multiple_streams_and_pressures_strea |
51 | 53 | ) |
52 | 54 |
|
53 | 55 |
|
54 | | -def _create_compressor_train_simplified_with_known_stages( |
55 | | - compressor_model_dto: CompressorTrainSimplifiedWithKnownStages, |
56 | | -) -> CompressorTrainSimplifiedKnownStages: |
57 | | - # Energy usage adjustment not supported for this model (yet) |
58 | | - # Issue error if factors are not default (and not changing the energy usage result) |
59 | | - |
60 | | - fluid_factory = _create_fluid_factory(compressor_model_dto.fluid_model) |
61 | | - if fluid_factory is None: |
62 | | - raise ValueError("Fluid model is required for compressor train") |
63 | | - return CompressorTrainSimplifiedKnownStages( |
64 | | - fluid_factory=fluid_factory, |
65 | | - energy_usage_adjustment_constant=compressor_model_dto.energy_usage_adjustment_constant, |
66 | | - energy_usage_adjustment_factor=compressor_model_dto.energy_usage_adjustment_factor, |
67 | | - stages=compressor_model_dto.stages, |
68 | | - calculate_max_rate=compressor_model_dto.calculate_max_rate, |
69 | | - maximum_power=compressor_model_dto.maximum_power, |
70 | | - ) |
71 | | - |
72 | | - |
73 | 56 | def _create_single_speed_compressor_train( |
74 | 57 | compressor_model_dto: SingleSpeedCompressorTrain, |
75 | 58 | ) -> SingleSpeedCompressorTrainCommonShaft: |
@@ -148,31 +131,69 @@ def _create_variable_speed_compressor_train_multiple_streams_and_pressures( |
148 | 131 | ) |
149 | 132 |
|
150 | 133 |
|
151 | | -def _create_compressor_train_simplified_with_unknown_stages( |
152 | | - compressor_model_dto: CompressorTrainSimplifiedWithUnknownStages, |
153 | | -) -> CompressorTrainSimplifiedUnknownStages: |
| 134 | +def _create_compressor_sampled(compressor_model_dto: CompressorSampled) -> CompressorModelSampled: |
| 135 | + return CompressorModelSampled( |
| 136 | + energy_usage_adjustment_constant=compressor_model_dto.energy_usage_adjustment_constant, |
| 137 | + energy_usage_adjustment_factor=compressor_model_dto.energy_usage_adjustment_factor, |
| 138 | + energy_usage_type=compressor_model_dto.energy_usage_type, |
| 139 | + energy_usage_values=compressor_model_dto.energy_usage_values, |
| 140 | + rate_values=compressor_model_dto.rate_values, |
| 141 | + suction_pressure_values=compressor_model_dto.suction_pressure_values, |
| 142 | + discharge_pressure_values=compressor_model_dto.discharge_pressure_values, |
| 143 | + power_interpolation_values=compressor_model_dto.power_interpolation_values, |
| 144 | + ) |
| 145 | + |
| 146 | + |
| 147 | +def create_compressor_train_simplified_from_known_stages( |
| 148 | + compressor_model_dto: CompressorTrainSimplifiedWithKnownStages, |
| 149 | +) -> CompressorTrainSimplified: |
| 150 | + """Create unified simplified compressor train model from known stages DTO.""" |
154 | 151 | fluid_factory = _create_fluid_factory(compressor_model_dto.fluid_model) |
155 | 152 | if fluid_factory is None: |
156 | 153 | raise ValueError("Fluid model is required for compressor train") |
157 | | - return CompressorTrainSimplifiedUnknownStages( |
| 154 | + |
| 155 | + # Create configuration for known stages |
| 156 | + config = KnownStagesConfig(stages=compressor_model_dto.stages) |
| 157 | + |
| 158 | + # Use centralized chart type detection |
| 159 | + supports_max_rate = SimplifiedTrainBuilder.supports_max_rate_calculation(compressor_model_dto.stages) |
| 160 | + |
| 161 | + return CompressorTrainSimplified( |
158 | 162 | fluid_factory=fluid_factory, |
159 | 163 | energy_usage_adjustment_constant=compressor_model_dto.energy_usage_adjustment_constant, |
160 | 164 | energy_usage_adjustment_factor=compressor_model_dto.energy_usage_adjustment_factor, |
161 | | - stage=compressor_model_dto.stage, |
162 | | - maximum_pressure_ratio_per_stage=compressor_model_dto.maximum_pressure_ratio_per_stage, |
| 165 | + stages=[], # Stages will be prepared later using the configuration |
163 | 166 | calculate_max_rate=compressor_model_dto.calculate_max_rate, |
164 | 167 | maximum_power=compressor_model_dto.maximum_power, |
| 168 | + supports_max_rate=supports_max_rate, |
| 169 | + stage_config=config, |
165 | 170 | ) |
166 | 171 |
|
167 | 172 |
|
168 | | -def _create_compressor_sampled(compressor_model_dto: CompressorSampled) -> CompressorModelSampled: |
169 | | - return CompressorModelSampled( |
| 173 | +def create_compressor_train_simplified_from_unknown_stages( |
| 174 | + compressor_model_dto: CompressorTrainSimplifiedWithUnknownStages, |
| 175 | +) -> CompressorTrainSimplified: |
| 176 | + """Create unified simplified compressor train model from unknown stages DTO.""" |
| 177 | + fluid_factory = _create_fluid_factory(compressor_model_dto.fluid_model) |
| 178 | + if fluid_factory is None: |
| 179 | + raise ValueError("Fluid model is required for compressor train") |
| 180 | + |
| 181 | + # Create configuration for unknown stages |
| 182 | + config = UnknownStagesConfig( |
| 183 | + stage_template=compressor_model_dto.stage, |
| 184 | + maximum_pressure_ratio_per_stage=compressor_model_dto.maximum_pressure_ratio_per_stage, |
| 185 | + ) |
| 186 | + |
| 187 | + # Use centralized chart type detection |
| 188 | + supports_max_rate = SimplifiedTrainBuilder.supports_max_rate_calculation([compressor_model_dto.stage]) |
| 189 | + |
| 190 | + return CompressorTrainSimplified( |
| 191 | + fluid_factory=fluid_factory, |
170 | 192 | energy_usage_adjustment_constant=compressor_model_dto.energy_usage_adjustment_constant, |
171 | 193 | energy_usage_adjustment_factor=compressor_model_dto.energy_usage_adjustment_factor, |
172 | | - energy_usage_type=compressor_model_dto.energy_usage_type, |
173 | | - energy_usage_values=compressor_model_dto.energy_usage_values, |
174 | | - rate_values=compressor_model_dto.rate_values, |
175 | | - suction_pressure_values=compressor_model_dto.suction_pressure_values, |
176 | | - discharge_pressure_values=compressor_model_dto.discharge_pressure_values, |
177 | | - power_interpolation_values=compressor_model_dto.power_interpolation_values, |
| 194 | + stages=[], # Stages will be prepared later using the configuration |
| 195 | + calculate_max_rate=compressor_model_dto.calculate_max_rate, |
| 196 | + maximum_power=compressor_model_dto.maximum_power, |
| 197 | + supports_max_rate=supports_max_rate, |
| 198 | + stage_config=config, |
178 | 199 | ) |
0 commit comments