Description
Describe the bug
When switching on the charger (changing from off to fast or by starting a plan), the charger systematically starts at high if not full power triggering the warning "over current detected". After some regulation cycles, the charger adjusts its power correctly to match the max current limit.
I cannot follow the calculation from the log... current in circuit is measured at 3.2 A (18:17:56), and with a limit of 10 A the max current set point should be 10-3.2 = 6.8 A, but lp-1 sets the limit to 13.8 A (18:17:57).
If this would be at the real limit of the circuit, this behaviour would burn the main fuse.
Steps to reproduce
- set current limit to 10A
- start charging (fast or plan)
- observe first power setting and warning in the log
...
Configuration details
site:
title: home
meters:
grid: my_grid
pv: my_pv
residualPower: -1000 # negativ erlaubt Netzbezug positiv erzwingt Einspeisung
interval: 10s
circuits:
- name: main
maxCurrent: 10
maxPower: 21000
meter: my_grid
parent:
loadpoints:
- title: Chargeur Garage
charger: Warp3
mode: pv # nach Ausstecken
circuit: main
enable:
threshold: 0 # positiv um noch bei Netzbezug zu starten
delay: 1m
disable:
threshold: 0 # positiv um noch Netzbezug zu erlauben
delay: 3m
chargers:
- name: Warp3
type: template
template: tinkerforge-warp3-smart
host: 192.168.1.40
port: 1883
timeout: 30s
topic: warp3/2haD
meters:
- name: my_grid
type: template
template: solaredge-inverter
usage: grid
modbus: tcpip
id: 1
host: 192.168.1.24
port: 1502
- name: my_pv
type: template
template: solaredge-inverter
usage: pv
modbus: tcpip
id: 1
host: 192.168.1.24
port: 1502Log details
[site ] DEBUG 2026/01/02 18:17:56 ----
[lp-1 ] DEBUG 2026/01/02 18:17:56 charge power: 0W
[circuit-main] DEBUG 2026/01/02 18:17:56 power: 855W
[circuit-main] DEBUG 2026/01/02 18:17:56 current: 3.2A
[site ] DEBUG 2026/01/02 18:17:56 grid power: 809W
[site ] DEBUG 2026/01/02 18:17:56 pv 1 power: 0W
[site ] DEBUG 2026/01/02 18:17:56 !! solar production: accumulate set my_pv 68876.248kWh meter total (was: Accumulated: 0.000kWh updated: 2026-01-02 18:17:46 +0100 CET meter: 68876.248kWh)
[site ] DEBUG 2026/01/02 18:17:56 !! solar production: accumulate moved my_pv from 0.000 to 0.000
[site ] DEBUG 2026/01/02 18:17:56 grid powers: [613 72 121]W
[site ] DEBUG 2026/01/02 18:17:57 grid currents: [3.2 1 1.3]A
[site ] DEBUG 2026/01/02 18:17:57 site power: -191W
[lp-1 ] DEBUG 2026/01/02 18:17:57 charger status: C
[lp-1 ] INFO 2026/01/02 18:17:57 start charging ->
[lp-1 ] DEBUG 2026/01/02 18:17:57 wake-up timer: stop
[circuit-main] DEBUG 2026/01/02 18:17:57 validate current: 3.2A + (7A -> 16A) > 10A capped at 13.8A
[lp-1 ] DEBUG 2026/01/02 18:17:57 set charge current limit: 13.8A
[site ] DEBUG 2026/01/02 18:18:06 ----
[lp-1 ] DEBUG 2026/01/02 18:18:06 charge power: 9522W
[circuit-main] DEBUG 2026/01/02 18:18:06 power: 10533W
[circuit-main] WARN 2026/01/02 18:18:06 over current detected: 11.9A > 10A
[site ] DEBUG 2026/01/02 18:18:06 grid power: 10536W
[site ] DEBUG 2026/01/02 18:18:06 pv 1 power: 0W
[site ] DEBUG 2026/01/02 18:18:06 !! solar production: accumulate set my_pv 68876.248kWh meter total (was: Accumulated: 0.000kWh updated: 2026-01-02 18:17:56 +0100 CET meter: 68876.248kWh)
[site ] DEBUG 2026/01/02 18:18:06 !! solar production: accumulate moved my_pv from 0.000 to 0.000
[site ] DEBUG 2026/01/02 18:18:06 grid powers: [3836 3329 3375]W
[site ] DEBUG 2026/01/02 18:18:06 grid currents: [11.9 9.6 9.7]A
[site ] DEBUG 2026/01/02 18:18:06 site power: 9536W
[lp-1 ] DEBUG 2026/01/02 18:18:06 session energy: 0.332kWh
[lp-1 ] DEBUG 2026/01/02 18:18:06 charger status: C
[circuit-main] DEBUG 2026/01/02 18:18:06 validate current: 11.9A + (13.8A -> 16A) > 10A capped at 11.9A
[lp-1 ] DEBUG 2026/01/02 18:18:06 set charge current limit: 11.9A
[site ] DEBUG 2026/01/02 18:18:16 ----
[lp-1 ] DEBUG 2026/01/02 18:18:16 charge power: 8211W
[circuit-main] DEBUG 2026/01/02 18:18:16 power: 9184W
[circuit-main] WARN 2026/01/02 18:18:16 over current detected: 14.5A > 10A
[site ] DEBUG 2026/01/02 18:18:16 grid power: 9176W
[site ] DEBUG 2026/01/02 18:18:16 pv 1 power: 0W
[site ] DEBUG 2026/01/02 18:18:16 !! solar production: accumulate set my_pv 68876.248kWh meter total (was: Accumulated: 0.000kWh updated: 2026-01-02 18:18:06 +0100 CET meter: 68876.248kWh)
[site ] DEBUG 2026/01/02 18:18:16 !! solar production: accumulate moved my_pv from 0.000 to 0.000
[site ] DEBUG 2026/01/02 18:18:16 grid powers: [3378 2871 2923]W
[site ] DEBUG 2026/01/02 18:18:16 grid currents: [14.5 12.2 12.4]A
[site ] DEBUG 2026/01/02 18:18:16 site power: 8176W
[lp-1 ] DEBUG 2026/01/02 18:18:16 session energy: 0.355kWh
[lp-1 ] DEBUG 2026/01/02 18:18:16 charger status: C
[circuit-main] DEBUG 2026/01/02 18:18:16 validate current: 14.5A + (11.9A -> 16A) > 10A capped at 7.4A
[lp-1 ] DEBUG 2026/01/02 18:18:16 set charge current limit: 7.4A
[site ] DEBUG 2026/01/02 18:18:26 ----
[lp-1 ] DEBUG 2026/01/02 18:18:26 charge power: 5106W
[circuit-main] DEBUG 2026/01/02 18:18:26 power: 5968W
[circuit-main] WARN 2026/01/02 18:18:26 over current detected: 10.1A > 10A
What type of operating system or environment does evcc run on?
Docker container
External automation
- I have made sure that no external automation like HomeAssistant or Node-RED is active or accessing any of the mentioned devices when this issue occurs.