@@ -5645,10 +5645,12 @@ \subsection{Chemical Time Integration}
5645
5645
\item \ct{MIN_EQUIV_RATIO}=0.0
5646
5646
\item \ct{MAX_EQUIV_RATIO}=20.0
5647
5647
\item \ct{DO_CHEM_LOAD_BALANCE}=T
5648
+
\item \ct{CVODE_ORDER}=0
5648
5649
\end{itemize}
5649
5650
The parameter \ct{FINITE_RATE_MIN_TEMP} defines the minimum temperature (in $^\circ$C) above which chemistry calculation will be performed. CVODE allows specification of relative and absolute tolerances at the species level using the \ct{ODE_REL_ERROR} and \ct{ODE_ABS_ERROR} parameters in the \ct{SPEC} input line. These tolerances can also be set globally in the \ct{COMB} input line, with species-level settings taking precedence. Currently, CVODE does not allow relative tolerance at the species level. The minimum concentration of a species is determined as the product of \ct{ODE_REL_ERROR} and \ct{ZZ_MIN_GLOBAL}. Concentrations below this threshold are treated as zero.
5650
5651
5651
-
Additional optional parameters include \ct{EQUIV_RATIO_CHECK}, \ct{MIN_EQUIV_RATIO}, and \ct{MAX_EQUIV_RATIO}. When \ct{EQUIV_RATIO_CHECK} is enabled (set to true), the chemistry calculation is performed only for those cells for which equivalence ratio is within the specified \ct{MIN_EQUIV_RATIO} and \ct{MAX_EQUIV_RATIO} limits, reducing computational time. Enabling \ct{DO_CHEM_LOAD_BALANCE} significantly accelerates chemistry calculations by distributing the computational load evenly across all MPI processes.
5652
+
Additional optional parameters include \ct{EQUIV_RATIO_CHECK}, \ct{MIN_EQUIV_RATIO}, and \ct{MAX_EQUIV_RATIO}. When \ct{EQUIV_RATIO_CHECK} is enabled (set to true), the chemistry calculation is performed only for those cells for which equivalence ratio is within the specified \ct{MIN_EQUIV_RATIO} and \ct{MAX_EQUIV_RATIO} limits, reducing computational time. Enabling \ct{DO_CHEM_LOAD_BALANCE} significantly accelerates chemistry calculations by distributing the computational load evenly across all MPI processes. The parameter \ct{CVODE_ORDER} controls the order of discretization when solving the ODE system. By default (0), CVODE dynamically selects an order between 1 and 5. For very stiff problems, the user may specify a lower order (1 or 2) to improve stability, at the cost of slower performance because CVODE will take much smaller internal substeps.
5653
+
5652
5654
User can modify the default values of any or all of these parameters as needed using the following line in the FDS input file:
5653
5655
\begin{lstlisting}
5654
5656
&COMB
@@ -11966,7 +11968,7 @@ \chapter{Alphabetical List of Input Parameters}
0 commit comments