Notifications
You must be signed in to change notification settings - Fork 41
Open
Description
Current Behaviour
If a timeout occurs before the client has received the full response body, no error is triggered despite the fact that the length of the returned body does not match the Content-Length header.
Expected Behaviour
If a timeout occurs before the client has received the full response body, an error condition should be raised.
Possible Fix
let set_error_and_handle t error =
Reader.force_close t.reader;
begin match !(t.state) with
| Closed -> ()
| Awaiting_response ->
set_error_and_handle_without_shutdown t error;
| Received_response(_, response_body) ->
Body.close_reader response_body;
Body.execute_read response_body;
set_error_and_handle_without_shutdown t error;
end
;;The order of instructions here is that the response body is closed before the error condition is raised. This triggered a handler for EOF before the error is set.
Setting the error first, fixes the issue in my testing:
let set_error_and_handle t error =
Reader.force_close t.reader;
begin match !(t.state) with
| Closed -> ()
| Awaiting_response ->
set_error_and_handle_without_shutdown t error;
| Received_response(_, response_body) ->
set_error_and_handle_without_shutdown t error;
Body.close_reader response_body;
Body.execute_read response_body;
end
;;Metadata
Metadata
Assignees
Labels
No labels