Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathsecure-zwave-energy-switch.groovy
More file actions
162 lines (142 loc) · 5.29 KB
/
Copy pathsecure-zwave-energy-switch.groovy
File metadata and controls
162 lines (142 loc) · 5.29 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
// UNTESTED
metadata {
// Automatically generated. Make future change here.
definition (name: "Secure Z-Wave Metering Switch", namespace: "jabbera", author: "Mike") {
capability "Energy Meter"
capability "Actuator"
capability "Switch"
capability "Power Meter"
capability "Polling"
capability "Refresh"
capability "Sensor"
command "reset"
fingerprint inClusters: "0x25,0x32"
}
// simulator metadata
simulator {
status "on": "command: 2003, payload: FF"
status "off": "command: 2003, payload: 00"
for (int i = 0; i <= 10000; i += 1000) {
status "power ${i} W": new physicalgraph.zwave.Zwave().meterV1.meterReport(
scaledMeterValue: i, precision: 3, meterType: 4, scale: 2, size: 4).incomingMessage()
}
for (int i = 0; i <= 100; i += 10) {
status "energy ${i} kWh": new physicalgraph.zwave.Zwave().meterV1.meterReport(
scaledMeterValue: i, precision: 3, meterType: 0, scale: 0, size: 4).incomingMessage()
}
// reply messages
reply "2001FF,delay 100,2502": "command: 2503, payload: FF"
reply "200100,delay 100,2502": "command: 2503, payload: 00"
}
// tile definitions
tiles {
standardTile("switch", "device.switch", width: 2, height: 2, canChangeIcon: true) {
state "on", label: '${name}', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821"
state "off", label: '${name}', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff"
}
valueTile("power", "device.power", decoration: "flat") {
state "default", label:'${currentValue} W'
}
valueTile("energy", "device.energy", decoration: "flat") {
state "default", label:'${currentValue} kWh'
}
standardTile("reset", "device.energy", inactiveLabel: false, decoration: "flat") {
state "default", label:'reset kWh', action:"reset"
}
standardTile("configure", "device.power", inactiveLabel: false, decoration: "flat") {
state "configure", label:'', action:"configuration.configure", icon:"st.secondary.configure"
}
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat") {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
}
main "switch"
details(["switch","power","energy","reset","configure","refresh"])
}
}
def parse(String description) {
def result = null
def cmd = zwave.parse(description, [0x20: 1, 0x32: 1])
if (cmd) {
result = createEvent(zwaveEvent(cmd))
}
return result
}
// Devices that support the Security command class can send messages in an encrypted form;
// they arrive wrapped in a SecurityMessageEncapsulation command and must be unencapsulated
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand([0x20: 1, 0x32: 1]) // can specify command class versions here like in zwave.parse
if (encapsulatedCommand) {
return zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.commands.meterv1.MeterReport cmd) {
if (cmd.scale == 0) {
[name: "energy", value: cmd.scaledMeterValue, unit: "kWh"]
} else if (cmd.scale == 1) {
[name: "energy", value: cmd.scaledMeterValue, unit: "kVAh"]
}
else {
[name: "power", value: Math.round(cmd.scaledMeterValue), unit: "W"]
}
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd)
{
[
name: "switch", value: cmd.value ? "on" : "off", type: "physical"
]
}
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd)
{
[
name: "switch", value: cmd.value ? "on" : "off", type: "digital"
]
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in
[:]
}
def on() {
delayBetween([
secure(zwave.basicV1.basicSet(value: 0xFF)),
secure(zwave.switchBinaryV1.switchBinaryGet())
])
}
def off() {
delayBetween([
secure(zwave.basicV1.basicSet(value: 0x00)),
secure(zwave.switchBinaryV1.switchBinaryGet())
])
}
def poll() {
delayBetween([
secure(zwave.switchBinaryV1.switchBinaryGet()),
secure(zwave.meterV2.meterGet(scale: 0)),
secure(zwave.meterV2.meterGet(scale: 2))
])
}
def refresh() {
delayBetween([
secure(zwave.switchBinaryV1.switchBinaryGet()),
secure(zwave.meterV2.meterGet(scale: 0)),
secure(zwave.meterV2.meterGet(scale: 2))
])
}
def reset() {
return [
secure(zwave.meterV2.meterReset()),
secure(zwave.meterV2.meterGet(scale: 0))
]
}
def configure() {
delayBetween([
secure(zwave.configurationV1.configurationSet(parameterNumber: 101, size: 4, scaledConfigurationValue: 4)), // combined power in watts
secure(zwave.configurationV1.configurationSet(parameterNumber: 111, size: 4, scaledConfigurationValue: 300)), // every 5 min
secure(zwave.configurationV1.configurationSet(parameterNumber: 102, size: 4, scaledConfigurationValue: 8)), // combined energy in kWh
secure(zwave.configurationV1.configurationSet(parameterNumber: 112, size: 4, scaledConfigurationValue: 300)), // every 5 min
secure(zwave.configurationV1.configurationSet(parameterNumber: 103, size: 4, scaledConfigurationValue: 0)), // no third report
secure(zwave.configurationV1.configurationSet(parameterNumber: 113, size: 4, scaledConfigurationValue: 300)) // every 5 min
])
}
private secure(physicalgraph.zwave.Command cmd) {
response(zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format())
}