The following list details alerts potentially returned by the device vitals API (e.g., /api/device/vitals). This data is aggregated from two primary sources:
- Tesla Residential Powerhub User Manual (Official)
- Community Contributions (Unofficial)
This list is non-exhaustive and may not cover every possible alert code.
Warning
Alert descriptions labeled as Community Contributed are generated through user observation and best-effort reverse engineering. These descriptions are not official Tesla documentation. They may contain inaccuracies or incomplete information.
- AC Blade Connector Damaged
- Backfeed Limited (BackfeedLimited)
- Battery Breaker Open
- Battery Comms
- Battery Fault (BatteryFault)
- Battery Meter Comms
- Battery Unexpected Power
- Battery Unexpected Reactive Power
- Black Start Failure
- Busway Meter Comms
- Contactor Unresponsive Close
- DC Bus Bar Shorted
- External IO Comms
- Frequency Meter Comms
- FWUpdateSucceeded
- Generator Breaker Timeout
- Generator Faulted
- Generator Meter Comms
- GridCodesWrite
- Grid Resynchronization Failed
- Inverter Not Going To Vf
- Islanding Controller MIA
- Load Meter Comms
- Lost Connectivity to Tesla Site Controller
- No Solar Production
- Opticaster Exe
- Permanent Battery Module Fault
- PINV_a010_can_gtwMIA
- PINV_a039_can_thcMIA
- PINV_a067_overvoltageNeutralChassis
- POD_f029_HW_CMA_OV
- POD_w024_HW_Fault_Asserted
- POD_w029_HW_CMA_OV
- POD_w031_SW_Brick_OV
- POD_w044_SW_Brick_UV_Warning
- POD_w045_SW_Brick_OV_Warning
- POD_w048_SW_Cell_Voltage_Sens
- POD_w058_SW_App_Boot
- POD_w063_SW_SOC_Imbalance
- POD_w067_SW_Not_Enough_Energy_Precharge
- POD_w090_SW_SOC_Imbalance_Limit_Charge
- POD_w093_SW_Charge_Request
- POD_w105_SW_EOD
- POD_w109_SW_Self_Test_Request_Not_Serviced
- POD_w110_SW_EOC
- PodCommissionTime
- Powerwall Inverter Failure
- Powerwall Performance Limited
- PV Inverter Comms
- PVS_a018_MciString[A-D]
- PVS_a026_Mci1PvVoltage
- PVS_a027_Mci2PvVoltage
- PVS_a031_Mci3PvVoltage
- PVS_a032_Mci4PvVoltage
- PV String Out
- Pyranometer Comms
- Ramp Rate Limited
- Reactive Power Limited
- Real Power Available Limited (RealPowerAvailableLimited)
- Real Power Config Limited
- ScheduledIslandContactorOpen
- SelfConsumptionReservedLimit
- Site Max Power Limited
- Site Meter Comms
- Site Min Power Limited (SiteMinPowerLimited)
- Smart Inverter Active
- Solar Charge Only Limited (SolarChargeOnlyLimited)
- Solar Meter Comms
- SYNC_a001_SW_App_Boot
- SYNC_a038_DoOpenArguments
- System shutdown
- THC_w061_CAN_TX_FIFO_Overflow
- THC_w155_Backup_Genealogy_Updated
- Wait for Solar
- Waiting for Jumpstart - Low SOE
- UI Name:
AC Blade Connector Damaged - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
RMA - Device:
Detected AC blade connector damage. Solar Inverter/assembly damaged, impacting solar production.
- UI Name:
Backfeed Limited - API Name:
BackfeedLimited - Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
STSTSM
The system is configured for inadvertent export and therefore will not further discharge to respect this limit
- UI Name:
Battery Breaker Open - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
There is an open breaker between the site meter and the powerwall itself. The meter will automatically detect when the breaker is closed again.
- UI Name:
Battery Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
Loss of communication to one or more inverter blocks.
- UI Name:
Battery Fault - API Name:
BatteryFault - Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
STSTSM
One or more inverter blocks is in a faulted state.
- UI Name:
Battery Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Battery Meter.
- UI Name:
Battery Unexpected Power - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
Commanded real power does not match measured power from battery meter
- UI Name:
Battery Unexpected Reactive Power - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
Commanded reactive power does not match measured power from battery meter
- UI Name:
Black Start Failure - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
The battery system was unable to black start.
- UI Name:
Busway Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Busway Meter.
- UI Name:
Contactor Unresponsive Close - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
The islanding controller was unable to open the islanding contactor/circuit breaker.
- UI Name:
DC Bus Bar Shorted - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
RMA - Device:
Detected DC bus bar short. Solar Inverter/assembly is damaged, impacting solar production.
- UI Name:
External IO Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with External IO device.
- UI Name:
Frequency Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Frequency Meter.
- UI Name:
- API Name:
FWUpdateSucceeded - Source:
Community Contributed - Severity:
- Device:
STSTSM
Firmware Upgrade Succeeded
- UI Name:
Generator Breaker Timeout - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
The generator was unable to close its breaker within the timeout window.
- UI Name:
Generator Faulted - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
The generator is in a faulted state.
- UI Name:
Generator Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Generator Meter.
- UI Name:
- API Name:
GridCodesWrite - Source:
Community Contributed - Severity:
- Device:
STSTSM
- UI Name:
Grid Resynchronization Failed - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
The islanding controller was unable to synchronize and close the islanding contactor/circuit breaker within 5 minutes.
- UI Name:
Inverter Not Going To Vf - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
The battery system is not transitioning to grid-forming mode.
- UI Name:
Islanding Controller MIA - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
Loss of communications with the islanding controller.
- UI Name:
Load Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Load Meter.
- UI Name:
Lost Connectivity to Tesla Site Controller - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
The Tesla Site Controller (or Gateway) has lost connectivity to Tesla Servers. Monitoring and management capabilities are currently limited.
- UI Name:
No Solar Production - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
One or more of the solar inverters have not produced any energy in the past 24 hours. There might be an issue impacting solar production.
- UI Name:
Opticaster Exe - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Critical - Device:
Opticaster failed to run on the Tesla Site Controller and the battery system is not being dispatched.
- UI Name:
Permanent Battery Module Fault - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
RMA - Device:
The Powerwall battery mode has permanently faulted and product needs replacement.
- UI Name:
- API Name:
PINV_a010_can_gtwMIA - Source:
Community Contributed - Severity:
- Device:
TEPINV
Indicate that gateway/sync is MIA (seen during firmware upgrade reboot)
- UI Name:
- API Name:
PINV_a039_can_thcMIA - Source:
Community Contributed - Severity:
- Device:
TEPINV
Seems to indicate that Home Controller is MIA (seen during firmware upgrade reboot)
- UI Name:
- API Name:
PINV_a067_overvoltageNeutralChassis - Source:
Community Contributed - Severity:
- Device:
TEPINV
- UI Name:
- API Name:
POD_f029_HW_CMA_OV - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w024_HW_Fault_Asserted - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w029_HW_CMA_OV - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w031_SW_Brick_OV - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w044_SW_Brick_UV_Warning - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w045_SW_Brick_OV_Warning - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w048_SW_Cell_Voltage_Sens - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w058_SW_App_Boot - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w063_SW_SOC_Imbalance - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w067_SW_Not_Enough_Energy_Precharge - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w090_SW_SOC_Imbalance_Limit_Charge - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w093_SW_Charge_Request - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w105_SW_EOD - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w109_SW_Self_Test_Request_Not_Serviced - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
POD_w110_SW_EOC - Source:
Community Contributed - Severity:
- Device:
TEPOD
- UI Name:
- API Name:
PodCommissionTime - Source:
Community Contributed - Severity:
- Device:
STSTSM
- UI Name:
Powerwall Inverter Failure - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
RMA - Device:
Powerwall inverter has failed permanently. Unit needs replacement.
- UI Name:
Powerwall Performance Limited - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
RMA - Device:
Powerwall has been locked out due to low energy. Unit needs replacement.
- UI Name:
PV Inverter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with PV Inverter.
- UI Name:
- API Name:
PVS_a018_MciString[A-D] - Source:
Community Contributed - Severity:
- Device:
PVS
This indicates a solar string (A, B, C or D) that is not connected.
- UI Name:
- API Name:
PVS_a026_Mci1PvVoltage - Source:
Community Contributed - Severity:
- Device:
PVS
- UI Name:
- API Name:
PVS_a027_Mci2PvVoltage - Source:
Community Contributed - Severity:
- Device:
PVS
- UI Name:
- API Name:
PVS_a031_Mci3PvVoltage - Source:
Community Contributed - Severity:
- Device:
PVS
- UI Name:
- API Name:
PVS_a032_Mci4PvVoltage - Source:
Community Contributed - Severity:
- Device:
PVS
- UI Name:
PV String Out - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
One or more solar inverter strings are not producing power, expect lower than usual solar performance.
- UI Name:
Pyranometer Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Pyranometer.
- UI Name:
Ramp Rate Limited - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
The output does not currently match the commanded power because the system is ramping to its setpoint
- UI Name:
Reactive Power Limited - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
The command is greater than the Available Reactive Power
- UI Name:
Real Power Available Limited - API Name:
RealPowerAvailableLimited - Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
STSTSM
The command is greater than the Available Battery Real Charge or Discharge Power
- UI Name:
Real Power Config Limited - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
The system is unable to meet the commanded power because of a limit that was configured during commissioning
- UI Name:
- API Name:
ScheduledIslandContactorOpen - Source:
Community Contributed - Severity:
- Device:
STSTSM
Manually Disconnected from Grid
- UI Name:
- API Name:
SelfConsumptionReservedLimit - Source:
Community Contributed - Severity:
- Device:
STSTSM
Battery reached reserve limit during self-consumption mode and switches to grid
- UI Name:
Site Max Power Limited - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
Cannot meet command because the Site Maximum Power Limit has been set
- UI Name:
Site Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Site Meter.
- UI Name:
Site Min Power Limited - API Name:
SiteMinPowerLimited - Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
STSTSM
Cannot meet command because the Site Minimum Power Limit has been set
- UI Name:
Smart Inverter Active - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
Due to grid conditions, a Smart Inverter Feature is now in operation on Battery Block X
- UI Name:
Solar Charge Only Limited - API Name:
SolarChargeOnlyLimited - Source:
Tesla - Residential Powerhub User Manual - Rev. 1.6 - Severity:
- Device:
STSTSM
The system has been configured to only charge from solar. Solar is not available; the charge request cannot be met
- UI Name:
Solar Meter Comms - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
Loss of communications with Solar Meter.
- UI Name:
- API Name:
SYNC_a001_SW_App_Boot - Source:
Community Contributed - Severity:
- Device:
TESYNC
- UI Name:
- API Name:
SYNC_a038_DoOpenArguments - Source:
Community Contributed - Severity:
- Device:
TESYNC
- UI Name:
System shutdown - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
The system has been shutdown by an external kill switch, or a system shutdown has been triggered by a low GPIO pin.
- UI Name:
- API Name:
THC_w061_CAN_TX_FIFO_Overflow - Source:
Community Contributed - Severity:
- Device:
TETHC
- UI Name:
- API Name:
THC_w155_Backup_Genealogy_Updated - Source:
Community Contributed - Severity:
- Device:
TETHC
Unknown but seen during firmware upgrade.
- UI Name:
Wait for Solar - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Performance - Device:
The site currently doesn't have enough SOE to form a grid. Waiting for more solar energy. Fix: User command or wait for daytime.
- UI Name:
Waiting for Jumpstart - Low SOE - API Name:
- Source:
Tesla - Residential Powerhub User Manual - Rev. 1.16 - Severity:
Informational - Device:
The system has been put to sleep due to a low SOE and being off-grid.