Notifications
You must be signed in to change notification settings - Fork 10
Expand file tree
/
Copy pathsolax_modbus_growatt_controller.py
More file actions
940 lines (833 loc) · 42.3 KB
/
Copy pathsolax_modbus_growatt_controller.py
File metadata and controls
940 lines (833 loc) · 42.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
"""Growatt MIN/SPH inverter controller using solax_modbus (TOU or VPP mode).
This controller supports Growatt inverters connected via the solax_modbus
HACS integration (local Modbus) instead of the growatt_server cloud
integration, covering both GEN4 (MIN/MOD/MID) and GEN3 (MIX/SPA/SPH) hardware.
Two control strategies are supported, selected via ``control_mode``:
- ``"tou"`` (default, GEN4 only) — a **single TOU segment** (slot 1) with a
full-day time window (00:00-23:59). The battery mode is updated per-period
via ``apply_period`` — only when the mode actually changes — reducing the
required entity count from 45 (9 slots x 5 entities) to just 5.
- ``"vpp"`` — Growatt's VPP remote power control registers (30100/30407-30410,
present on both GEN3 and GEN4 per the solax_modbus Growatt plugin source),
applying per-period power commands with no persistent schedule at all —
the same "SM-Ephemeral" model ``SolaxController`` already uses for real
SolaX hardware. See issue #118: GEN3 has no working TOU path today, so VPP
is its only control mode; GEN4 gets a choice, with VPP intended to
eventually replace TOU once proven on real hardware.
Mode semantics (TOU):
- ``load_first`` — inverter default when no TOU segment is active
- ``battery_first`` — charge from grid + solar (GRID_CHARGING intent)
- ``grid_first`` — export to grid (BATTERY_EXPORT intent)
VPP intent -> power mapping originally mirrored ``SolaxController``, plus a
block_passive_charging distinction at rate=0 (#355 -- see
docs/superpowers/specs/2026-07-20-vpp-passive-charge-block-design.md).
LOAD_SUPPORT has since diverged (#413 -- see below): ``SolaxController``
still forces a rate for it, this controller now releases VPP control instead.
- GRID_CHARGING -> power=+100%, remote_control enabled
- BATTERY_EXPORT (rate>0) -> power=-rate%, remote_control enabled
- LOAD_SUPPORT (any rate) -> power=0, remote_control DISABLED, regardless
of discharge_rate (#413 -- releases control to the inverter's own
load-following self-use instead of forcing a fixed discharge rate, which
causes unnecessary grid imports/exports whenever the schedule's load
prediction misses)
- SOLAR_STORAGE (rate=0, block_passive_charging=False) -> remote_control
disabled (load_first self-use -- battery may absorb solar surplus)
- IDLE (rate=0) -> power=+1%, remote_control ENABLED (battery-first hold,
per the Growatt VPP protocol V2.01 section 3.5 -- #466: load_first
self-use discharges the battery to cover house load, but the DP's own
cost model never credits battery discharge during IDLE
(_idle_battery_flows in dp_battery_algorithm.py); battery-first keeps
self-consumption on grid/solar instead. grid_first (power<=0) does not
achieve this -- per #118, self-consumption is still drawn from the
battery in grid_first, only battery-first releases it to grid/solar)
- IDLE (rate=0) **at the reserve floor** -> power=0, remote_control
DISABLED (#592 -- the hold above protects stored energy, and at the floor
there is none left to protect; keeping remote control enabled rewrites the
command every period to refresh the fallback timer, so the inverter is
never handed back and its BMS never sleeps). Releasing rather than
commanding power=0 with remote control enabled is what keeps this
flow-neutral -- see _intent_to_vpp
- SOLAR_EXPORT (rate=0, block_passive_charging=True) -> power=0,
remote_control ENABLED (grid_first hold, per the Growatt VPP protocol
V2.01 section 3.5 -- battery held flat, solar bypasses to grid)
The VPP fallback timer (``vpp_time``, register 30408) is rewritten every
active period, resetting the inverter's own dead-man's-switch: if BESS stops
writing (crash, restart), the inverter reverts to load_first on its own once
the timer lapses — the same safety property ``SolaxController`` gets from
SolaX's autorepeat duration.
"""
import logging
import time
from typing import ClassVar
from . import time_utils
from .dp_schedule import DPSchedule
from .growatt_min_controller import GrowattMinController
from .health_check import perform_health_check
from .settings import BatterySettings
logger = logging.getLogger(__name__)
# VPP fallback timer, in minutes. Must be > 15 (period length) so a normal
# hourly re-optimization cadence never lets the timer lapse; keeps the
# inverter's dead-man's-switch tight if BESS actually stops writing.
_VPP_FALLBACK_MINUTES = 20
class SolaxModbusGrowattController(GrowattMinController):
"""Growatt MIN/SPH controller using solax_modbus, TOU or VPP control.
``control_mode="tou"`` manages a single TOU segment (slot 1), updating its
mode each period when needed. ``control_mode="vpp"`` issues per-period VPP
power commands instead, with no persistent TOU schedule — analogous to
how ``SolaxController`` applies per-period VPP commands for real SolaX
hardware, with ``sync_to_hardware`` doing only the one-time VPP
enable sequence.
"""
# TOU mode's per-period write goes through the inherited base
# _write_period_to_hardware() (#166 comment above _apply_period_tou):
# writes unconditionally rather than gating on the last-written value,
# since the #166 gate-removal is itself an active real-hardware test on
# GEN4. Do not let GrowattMinController's dedupe_register_writes (#402,
# cloud-only) silently re-gate this.
dedupe_register_writes: ClassVar[bool] = False
# Export-limit registers (122/123) exist independent of control_mode —
# true in both TOU and VPP mode, unlike supports_charge_rate_control.
supports_export_limit_control: ClassVar[bool] = True
def __init__(
self, battery_settings: BatterySettings, control_mode: str = "tou"
) -> None:
"""Initialize the Growatt solax_modbus controller.
Args:
battery_settings: Battery configuration.
control_mode: "tou" (single-segment TOU, GEN4 default) or "vpp"
(VPP remote power control, GEN3's only control mode).
"""
super().__init__(battery_settings)
if control_mode not in ("tou", "vpp"):
raise ValueError(
f"Unknown control_mode {control_mode!r}, expected 'tou' or 'vpp'"
)
self.control_mode = control_mode
self._last_written_tou_mode: str | None = None
# VPP-only state, seeded from hardware in read_and_initialize_from_hardware
# rather than persisted as class-level statics — controllers are
# recreated each optimization cycle, so state must survive via
# read-back, the same pattern TOU mode already uses.
# One flag per flash register, not one for both: they are written
# together but can drift apart, and repairing the drifted one must not
# cost a redundant flash write on the healthy one (#399).
self._vpp_status_confirmed: bool = False
self._vpp_ac_charging_confirmed: bool = False
self._last_written_vpp_remote_control: bool | None = None
self._last_written_vpp_power: int | None = None
@property
def _is_tou_control(self) -> bool:
"""Single source of truth for the TOU-vs-VPP capability split below.
True in TOU mode: the EMS charge/discharge-rate registers are used
directly, and discharge_rate acts as a load_first ceiling. False in
VPP mode: power is driven by vpp_power (RAM) instead, as an
immediate forced command (#324) -- neither EMS-rate-control nor
load-following semantics apply.
"""
return self.control_mode != "vpp"
@property
def CONTROL_MODEL(self) -> str:
"""Dual-mode: real TOU register in "tou" mode, VPP power+remote_control
in "vpp" mode — see _is_tou_control for the underlying capability
split this mirrors."""
return "tou_register" if self._is_tou_control else "vpp_power"
@property
def supports_charge_rate_control(self) -> bool:
"""VPP mode drives power via vpp_power (RAM); no EMS rate writes.
TOU mode still uses the EMS charge/discharge-rate registers
directly, so this stays True there (base class default).
"""
return self._is_tou_control
def apply_export_limit(self, controller, curtail: bool) -> None:
"""Curtail/release PV export via the CT-meter export-limit registers
(122/123, issue #269). Independent of control_mode (tou/vpp)."""
controller.set_growatt_export_limit(curtail)
@property
def discharge_rate_is_load_following(self) -> bool:
"""TOU mode's discharge_rate is a load_first ceiling; VPP mode's is
an immediate forced vpp_power command. See #324.
"""
return self._is_tou_control
# ── Abstract property ────────────────────────────────────────────────────
@property
def active_tou_intervals(self) -> list[dict]:
"""Return the single TOU segment if active, else empty list.
Always empty in VPP mode — there is no persistent TOU schedule.
"""
return self._active_tou_intervals
@active_tou_intervals.setter
def active_tou_intervals(self, value: list[dict]) -> None:
self._active_tou_intervals = value
# ── Schedule creation ────────────────────────────────────────────────────
def apply_intents(self, schedule: DPSchedule, current_period: int = 0) -> None:
"""Adopt this cycle's DP intent list — control is applied per-period,
no batch TOU/VPP schedule computed here.
Skips the parent's 9-segment TOU interval computation. Strategic intents
are stored and hourly settings calculated for API/display consumption.
Args:
schedule: DPSchedule containing strategic_intent list.
current_period: Current 15-minute period (0-95).
"""
logger.info(
"Creating %s schedule from strategic intents", self.control_mode.upper()
)
self.strategic_intents = schedule.original_dp_results["strategic_intent"]
self.current_schedule = schedule
logger.info(
"%s: %d strategic intents loaded (quarterly resolution)",
self.control_mode.upper(),
len(self.strategic_intents),
)
# Log intent transitions from current_period onward — periods before
# current_period are already elapsed and re-log identically on every
# hourly re-optimization otherwise.
for period in range(max(1, current_period), len(self.strategic_intents)):
if self.strategic_intents[period] != self.strategic_intents[period - 1]:
logger.info(
"Intent transition at period %d: %s -> %s",
period,
self.strategic_intents[period - 1],
self.strategic_intents[period],
)
if self.control_mode == "tou":
self._update_tou_display_state()
# ── Hardware interface ────────────────────────────────────────────────────
def apply_period(
self,
controller,
grid_charge: bool,
discharge_rate: int,
block_passive_charging: bool = False,
strategic_intent: str = "",
at_reserve_floor: bool = False,
) -> tuple[bool, str]:
"""Write period control settings for the current control mode.
Args:
controller: HomeAssistantAPIController instance
grid_charge: Whether to enable grid charging
discharge_rate: Discharge power rate (0-100%), post-inhibit
block_passive_charging: Whether passive solar->battery charging
should be blocked this period (SOLAR_EXPORT). TOU mode
ignores this -- realized via the separate charge_rate
register instead. VPP mode acts on it directly (#355): it
has no charge_rate register, so this is its only channel for
distinguishing SOLAR_EXPORT (hold, block charging) from
SOLAR_STORAGE (self-use, allow charging) at discharge_rate=0.
IDLE is intercepted earlier via strategic_intent (#466) and
does not reach this flag.
strategic_intent: The period's strategic intent string. TOU mode
ignores this (it derives mode from strategic_intents itself).
VPP mode acts on it directly: distinguishes LOAD_SUPPORT
(#413) and IDLE (#466) from other rate=0 intents --
grid_charge/discharge_rate/block_passive_charging alone
can't tell them apart, but VPP mode must, since each needs a
different remote_control/power command.
at_reserve_floor: Whether the battery is currently at (or below)
its configured minimum SoE. TOU mode ignores this. VPP mode
uses it to release the IDLE hold (#592) -- see
_intent_to_vpp. Derived from a live SoC read, not from the
plan: the hold exists to protect stored energy, so what
matters is whether any is actually there now.
Returns:
Tuple of (success, error_message). error_message is empty on success.
"""
if self.control_mode == "vpp":
return self._apply_period_vpp(
controller,
grid_charge,
discharge_rate,
block_passive_charging,
strategic_intent,
at_reserve_floor,
)
return self._apply_period_tou(controller, grid_charge, discharge_rate)
def _apply_period_tou(
self, controller, grid_charge: bool, discharge_rate: int
) -> tuple[bool, str]:
"""Write period control settings, including TOU mode update when needed.
Derives the required TOU mode from the current period's strategic intent.
Only writes the TOU segment when the mode actually changes, minimising
inverter writes.
"""
errors = []
now = time_utils.now()
current_period = now.hour * 4 + now.minute // 15
mode = "load_first"
if current_period < len(self.strategic_intents):
intent = self.strategic_intents[current_period]
mode = self.INTENT_TO_MODE.get(intent, "load_first")
if mode != self._last_written_tou_mode:
enabled = mode != "load_first"
logger.info(
"TOU segment 1 mode: %s -> %s (period %d, intent %s)",
self._last_written_tou_mode,
mode,
current_period,
intent,
)
try:
controller.set_tou_segment_via_entities(
segment_id=1,
batt_mode=mode,
start_time="00:00",
end_time="23:59",
enabled=enabled,
)
self._last_written_tou_mode = mode
self._update_tou_display_state()
except Exception as e:
logger.error("FAILED: set TOU segment mode to %s: %s", mode, e)
errors.append(str(e))
# #166 added a gate here to skip writing discharge_rate=0 in load_first
# mode, on the theory that it disables the inverter's native self-use
# discharge. That theory was never confirmed against real hardware and
# left SOLAR_STORAGE/IDLE with a stale discharge_rate register (#issue
# reported by Doodlehusse on #200 follow-up). This beta build removes
# the gate to test on real GEN4 hardware — writes unconditionally, same
# as GrowattMinController's cloud path.
success, error_msg = self._write_period_to_hardware(
controller, grid_charge, discharge_rate
)
if not success:
errors.append(error_msg)
if errors:
return False, "; ".join(errors)
return True, ""
def _intent_to_vpp(
self,
grid_charge: bool,
discharge_rate: int,
block_passive_charging: bool = False,
strategic_intent: str = "",
at_reserve_floor: bool = False,
) -> tuple[int, bool]:
"""Map (grid_charge, discharge_rate, block_passive_charging,
strategic_intent, at_reserve_floor) to
(power_pct, remote_control_enabled).
- grid_charge=True -> +100% (charge at max rate)
- grid_charge=False, intent=LOAD_SUPPORT -> 0%, remote control
DISABLED, regardless of rate (#413 -- releases control to the
inverter's own load-following self-use instead of forcing a fixed
discharge rate, which causes unnecessary grid imports/exports
whenever the schedule's load prediction misses). Checked before
the rate=0/block_passive_charging branch below: LOAD_SUPPORT's
INTENT_TO_CONTROL charge_rate is 0 (same as BATTERY_EXPORT/
SOLAR_EXPORT), so block_passive_charging is True for it in
production whenever discharge_rate is also 0 (a common case --
the DP plan calling for no net discharge, or discharge-inhibit
forcing the rate to 0) -- without this ordering that would wrongly
fall into the grid_first-hold branch below instead of releasing.
- grid_charge=False, rate=0, block=True -> 0%, remote control ENABLED
(SOLAR_EXPORT). Per the Growatt VPP protocol (V2.01, section 3.5),
vpp_power<=0 with remote control enabled selects "grid first"
priority, holding the battery instead of self-use absorbing solar
surplus into it -- see #355 and
docs/superpowers/specs/2026-07-20-vpp-passive-charge-block-design.md.
Not yet real-hardware-validated; ships experimental pending
confirmation.
- grid_charge=False, rate=0, intent=IDLE -> +1%, remote control
ENABLED (#466 -- "battery first" per the protocol's >0 branch).
IDLE's own DP cost model never credits battery discharge for load
(_idle_battery_flows), so self-consumption must come from
grid/solar, not the battery. grid_first (this function's block=True
branch) does NOT achieve that -- per #118, self-consumption is
still drawn from the battery under grid_first; only battery_first
releases it to grid/solar. Checked before the generic rate=0
branch below so IDLE doesn't fall into SOLAR_STORAGE's self-use
disable. Not yet real-hardware-validated; ships experimental
pending confirmation.
- grid_charge=False, rate=0, intent=IDLE, at_reserve_floor=True
-> 0%, remote control DISABLED (#592). The battery_first hold above
protects stored energy from self-consumption; at the floor there is
none left to protect, so it buys nothing and costs the inverter its
sleep -- remote control being enabled makes _apply_period_vpp
rewrite the command every period to refresh the fallback timer
(#404), so the inverter is never handed back and the BMS never
idles down.
Releasing, rather than writing power=0 with remote control still
enabled (which is grid_first), is what keeps this flow-neutral:
load_first still absorbs passive solar surplus exactly as the
battery_first hold does, where grid_first would bypass it to the
grid -- a real change, since IDLE's DP cost model does credit that
absorption. Flow-neutrality is proved in
test_vpp_simulator_branches.py::TestIdleAtReserveFloor.
**How far the battery can actually fall is the inverter's own
discharge_stop_soc, not BESS's min_soc, and in VPP mode BESS does
not write that register** -- initialize_hardware returns before
sync_soc_limits for control_mode="vpp" (#309). So if the inverter's
own floor sits below the configured min_soc, released self-use can
draw the gap between them to cover house load. That is not new
here: LOAD_SUPPORT (#413) and SOLAR_STORAGE already release control
the same way at any SoC, so this extends an existing exposure to
IDLE rather than creating one -- and it is bounded by the gap
between the two floors, which is zero on a correctly configured
inverter. `vpp_simulator` models the release as a hold at
min_soe_kwh (available == 0), i.e. it assumes the two floors agree.
Flagged for real-hardware confirmation with #592's reporter.
- grid_charge=False, rate=0, block=False -> 0%, remote control DISABLED
(load_first self-use -- SOLAR_STORAGE, battery may absorb solar)
- grid_charge=False, rate>0 (otherwise, i.e. BATTERY_EXPORT)
-> -rate% (discharge/export)
"""
if grid_charge:
return 100, True
if strategic_intent == "LOAD_SUPPORT":
return 0, False
if discharge_rate == 0:
if strategic_intent == "IDLE":
return (0, False) if at_reserve_floor else (1, True)
return 0, block_passive_charging
return -discharge_rate, True
def _vpp_display_state(
self,
grid_charge: bool,
discharge_rate: int,
block_passive_charging: bool = False,
strategic_intent: str = "",
) -> tuple[int, bool]:
"""Display-facing alias for _intent_to_vpp().
The base class's _mode_display_fields() calls _vpp_display_state()
uniformly across all vpp_power controllers (see
core/bess/inverter_controller.py) rather than duck-typing a
subclass-private method name. This is a pure interface unification
wrapper -- _intent_to_vpp()'s own logic is unchanged.
"""
return self._intent_to_vpp(
grid_charge, discharge_rate, block_passive_charging, strategic_intent
)
def _ensure_vpp_status_enabled(self, controller) -> None:
"""Enable the two VPP flash registers, each only if not already confirmed.
VPP Remote Control has no effect while VPP Status is disabled — this
must be written (with a settle delay) before the first Remote Control
write, per real-hardware testing on issue #118. AC charging is the
second register of the pair: without it GRID_CHARGING periods draw
nothing from the grid.
Confirmed **per register**. They are written together but can drift
apart (a user toggle, a firmware reset, a write that failed after the
first of the two), and both are flash — so when only one has drifted,
rewriting the healthy one is exactly the wear #399 asked to eliminate.
"""
if self._vpp_status_confirmed and self._vpp_ac_charging_confirmed:
return
if not self._vpp_status_confirmed:
controller.set_growatt_vpp_status(True)
self._vpp_status_confirmed = True
if not self._vpp_ac_charging_confirmed:
controller.set_growatt_vpp_allow_ac_charging(True)
self._vpp_ac_charging_confirmed = True
time.sleep(1)
def leave_control_mode(self, controller) -> None:
"""Disable VPP Status when switching away from VPP mode (#479).
Without this, VPP Remote Control keeps overriding TOU segment
writes at the hardware level even after BESS's own control_mode
has switched to "tou" -- see module docstring and
_ensure_vpp_status_enabled(). Reads live hardware state rather than
self._vpp_status_confirmed, so this also recovers an install stuck
from before this fix existed -- toggling control_mode to "vpp" and
back to "tou" leaves this hardware register in the same disabled
state a fresh install would end up in.
"""
if self.control_mode != "vpp":
return
if controller.get_growatt_vpp_status() == "Enabled":
controller.set_growatt_vpp_status(False)
def _apply_period_vpp(
self,
controller,
grid_charge: bool,
discharge_rate: int,
block_passive_charging: bool = False,
strategic_intent: str = "",
at_reserve_floor: bool = False,
) -> tuple[bool, str]:
"""Write one period's VPP power command.
Writes every period while remote control is active, refreshing the
fallback timer so the inverter's dead-man's-switch never lapses
during a stable run of identical periods (#404). Only skipped when
remote control is (and was already) disabled — nothing active, no
timer to protect.
"""
power_pct, remote_control_enabled = self._intent_to_vpp(
grid_charge,
discharge_rate,
block_passive_charging,
strategic_intent,
at_reserve_floor,
)
needs_write = remote_control_enabled or (
remote_control_enabled != self._last_written_vpp_remote_control
)
if not needs_write:
return True, ""
try:
self._ensure_vpp_status_enabled(controller)
controller.set_growatt_vpp_period(
remote_control_enabled=remote_control_enabled,
power_pct=power_pct,
fallback_minutes=_VPP_FALLBACK_MINUTES,
)
self._last_written_vpp_remote_control = remote_control_enabled
# Release zeroes 30409 (#593), so 0 -- not None -- is the truth.
self._last_written_vpp_power = power_pct if remote_control_enabled else 0
return True, ""
except Exception as e:
logger.error("FAILED: Growatt VPP period write: %s", e)
return False, str(e)
def sync_to_hardware(
self,
controller,
effective_period: int,
) -> tuple[int, int]:
"""Initialise hardware for the current control mode.
TOU mode: sets segment 1 to the current period's mode with a full-day
window. Legacy segments 2-9 are cleaned up at startup
(read_and_initialize_from_hardware), not here.
VPP mode: enables VPP Status/AC-charging once. No power command is
issued here — VPP has no persistent/bulk schedule to push, and
BatterySystemManager._apply_period_schedule always writes the
current period's real power command immediately after this call
returns (via apply_period). Issuing a power command here as well
used to compute it from a hardcoded battery_action_kw=0.0 stub,
sending a spurious power=0% write that briefly preceded the correct
value written moments later (#421).
Args:
controller: HomeAssistantAPIController instance
effective_period: Period (0-95) from which to start applying changes
Returns:
Tuple of (segments_updated, segments_disabled)
"""
if self.control_mode == "vpp":
self._ensure_vpp_status_enabled(controller)
return (0, 0)
mode = "load_first"
if effective_period < len(self.strategic_intents):
intent = self.strategic_intents[effective_period]
mode = self.INTENT_TO_MODE.get(intent, "load_first")
enabled = mode != "load_first"
logger.info(
"Modbus: writing initial TOU segment 1 — mode=%s, enabled=%s",
mode,
enabled,
)
controller.set_tou_segment_via_entities(
segment_id=1,
batt_mode=mode,
start_time="00:00",
end_time="23:59",
enabled=enabled,
)
self._last_written_tou_mode = mode
self._update_tou_display_state()
return 1, 0
def read_and_initialize_from_hardware(self, controller, current_hour: int) -> None:
"""Read current control state from hardware and seed internal trackers.
Pure read — no hardware writes. VPP mode reads back the VPP Status and
Remote Control registers so state survives controller
re-instantiation (BESS recreates the controller each optimization
cycle) without resorting to class-level statics.
"""
self.current_hour = current_hour
if self.control_mode == "vpp":
status = controller.get_growatt_vpp_status()
allow_ac_charging = controller.get_growatt_vpp_allow_ac_charging()
# Both registers, each seeding its own flag, because
# _ensure_vpp_status_enabled writes them independently. Seeding a
# single flag from VPP Status alone made Status a proxy for a
# register that was never read: an inverter with Status Enabled
# but AC charging Disabled was treated as fully configured on
# every restart, so the AC-charging write never happened again and
# GRID_CHARGING periods silently drew nothing from the grid.
#
# A read that returns None (transient API error, entity
# momentarily unavailable, or the entity not configured at all) is
# *unknown*, not "Disabled" — but unknown still cannot be assumed
# good, since a wrongly-assumed Enabled leaves VPP unable to
# execute its plan with no further chance to repair. It is
# therefore repaired like a known-wrong register, and logged as
# unknown so the flash write has a visible cause. Per-register
# confirmation keeps that to the one register that could not be
# read.
for register, state in (
("status", status),
("allow_ac_charging", allow_ac_charging),
):
if state is None:
logger.warning(
"Growatt VPP: could not read %s (unknown, not "
"necessarily disabled) — it will be rewritten on the "
"next VPP command",
register,
)
self._vpp_status_confirmed = status == "Enabled"
self._vpp_ac_charging_confirmed = allow_ac_charging == "Enabled"
remote_control = controller.get_growatt_vpp_remote_control()
self._last_written_vpp_remote_control = (
remote_control == "Enabled" if remote_control is not None else None
)
logger.info(
"Growatt VPP: initialised from hardware — status=%s "
"allow_ac_charging=%s remote_control=%s",
status,
allow_ac_charging,
remote_control,
)
return
segments = controller.read_tou_segments_from_entities()
# Seed mode tracker from segment 1
seg1 = next((s for s in segments if s["segment_id"] == 1), None)
if seg1 and seg1.get("enabled"):
self._last_written_tou_mode = seg1["batt_mode"]
logger.info(
"Modbus: initialised from hardware — segment 1 mode=%s",
self._last_written_tou_mode,
)
else:
self._last_written_tou_mode = "load_first"
logger.info(
"Modbus: initialised from hardware — no active TOU segment, defaulting to load_first"
)
# Set display state
self._update_tou_display_state()
def _disable_legacy_tou_slots(self, controller) -> None:
"""Disable any TOU slots 2-9 still enabled from a previous 9-segment config.
On startup, reads all available TOU slots (1-9). Any slot 2-9 that is
found enabled gets disabled — handles migration from the old 9-segment
approach regardless of how many slots the user had enabled.
"""
segments = controller.read_tou_segments_from_entities()
disabled_count = 0
for seg in segments:
if seg["segment_id"] >= 2 and seg.get("enabled", False):
logger.info(
"Disabling legacy TOU slot %d (%s %s-%s) — "
"single-segment mode active",
seg["segment_id"],
seg.get("batt_mode", "?"),
seg.get("start_time", "?"),
seg.get("end_time", "?"),
)
controller.set_tou_segment_via_entities(
segment_id=seg["segment_id"],
batt_mode="load_first",
start_time="00:00",
end_time="00:00",
enabled=False,
)
disabled_count += 1
if disabled_count > 0:
logger.info("Migration: disabled %d legacy TOU slot(s)", disabled_count)
def initialize_hardware(self, controller) -> None:
if self.control_mode == "vpp":
# VPP mode must never touch TOU entities — not even to disable
# them. A GEN4 install switching tou -> vpp with a still-active
# TOU segment relies on the user (or setup wizard guidance) to
# clear it, not on a runtime write here — see issue #309.
return
self._disable_legacy_tou_slots(controller)
super().initialize_hardware(controller)
# ── Schedule comparison ──────────────────────────────────────────────────
@staticmethod
def _diff_intents(
current: list[str], new: list[str], from_period: int
) -> tuple[bool, str]:
"""Shared diff rule for strategic-intent lists.
Two schedules differ when any period at or after ``from_period`` has a
different strategic intent.
"""
if not current and not new:
return False, ""
if len(current) != len(new):
return True, (f"Modbus intent count differs: {len(current)} vs {len(new)}")
for period in range(from_period, len(current)):
if current[period] != new[period]:
logger.info(
"DECISION: Modbus intent differs at period %d — "
"current=%s new=%s",
period,
current[period],
new[period],
)
return True, (f"Modbus strategic intents differ from period {period}")
logger.info("DECISION: Modbus schedules match")
return False, ""
def reconcile_hardware(self, controller, effective_period: int) -> tuple[int, int]:
"""Nothing to re-assert — and specifically not the parent's version.
The parent reconciles by re-running its own sync, which reads the
inverter's segment table over the growatt_server cloud services. This
platform is modbus: there is no Growatt device_id to address, so
inheriting that raises SystemConfigurationError and takes the whole
schedule update with it (issue #554).
It is also unnecessary here. TOU mode drives a single segment whose
mode is rewritten whenever it differs, and VPP mode issues per-period
commands, so neither skips a write while the plan holds steady the way
the parent does — there is no window in which drift could go unnoticed.
"""
return 0, 0
def evaluate_intents(
self, schedule: DPSchedule, current_period: int = 0
) -> tuple[bool, str]:
"""Compare schedules by strategic intent list (like SolaxController).
Two schedules differ when any period at or after ``current_period``
has a different strategic intent.
"""
new = schedule.original_dp_results["strategic_intent"]
return self._diff_intents(self.strategic_intents, new, current_period)
# ── TOU display ──────────────────────────────────────────────────────────
def _update_tou_display_state(self) -> None:
"""Update internal TOU interval lists for API/display consumption."""
mode = self._last_written_tou_mode or "load_first"
enabled = mode != "load_first"
if enabled:
segment = {
"segment_id": 1,
"batt_mode": mode,
"start_time": "00:00",
"end_time": "23:59",
"enabled": True,
}
self.tou_intervals = [segment]
self._active_tou_intervals = [segment]
else:
self.tou_intervals = []
self._active_tou_intervals = []
def get_daily_TOU_settings(self) -> list[dict]:
"""Return the single TOU segment if active. Always empty in VPP mode."""
if not self.tou_intervals:
return []
return [seg.copy() for seg in self.tou_intervals]
def get_all_tou_segments(self, current_period: int | None = None):
"""Return TOU segments with defaults for complete 24-hour coverage.
For the single-segment/VPP approach, returns strategic-intent groups
as display segments (no hardware TOU segments exist in VPP mode).
"""
groups = self.get_detailed_period_groups()
if not groups:
return [
{
"segment_id": 0,
"start_time": "00:00",
"end_time": "23:59",
"enabled": False,
"is_default": True,
**(
{"batt_mode": "load_first"}
if self.CONTROL_MODEL == "tou_register"
else {}
),
}
]
# Build display from intent groups (same approach as SolaxController)
now = time_utils.now()
current_p = now.hour * 4 + now.minute // 15
result = []
for group in groups:
block_passive_charging = (
self.INTENT_TO_CONTROL.get(group["intent"], {}).get("charge_rate") == 0
)
mode_fields = self._mode_display_fields(
group["intent"],
group["grid_charge"],
group["discharge_rate"],
block_passive_charging,
)
is_current = group["start_period"] <= current_p <= group["end_period"]
is_default_display = mode_fields.get("batt_mode") == "load_first"
result.append(
{
"segment_id": len(result) + 1,
"start_time": group["start_time"],
"end_time": group["end_time"],
**mode_fields,
"enabled": not is_default_display,
"is_default": is_default_display,
"is_current": is_current,
"strategic_intent": group["intent"],
}
)
return result
def log_current_TOU_schedule(self, header=None) -> None:
"""Log current single-segment TOU state, or VPP command state."""
if header:
logger.info(header)
if self.control_mode == "vpp":
if self._last_written_vpp_remote_control:
logger.info(
"Growatt VPP: remote control enabled, power=%s%%",
self._last_written_vpp_power,
)
else:
logger.info("Growatt VPP: remote control disabled (load_first)")
return
mode = self._last_written_tou_mode or "load_first"
if mode == "load_first":
logger.info("Modbus: TOU segment 1 disabled (load_first default)")
else:
logger.info("Modbus: TOU segment 1 = %s (00:00-23:59)", mode)
# ── Health check ─────────────────────────────────────────────────────────
def check_health(self, controller) -> list:
"""Check battery control capabilities for the active control mode."""
# grid_charge_enabled is shared by both modes; the EMS rate/stop-SOC
# entities are TOU-only — VPP setups commonly have them disabled in
# HA since VPP mode never reads or writes them (issue #308).
all_methods = (
["grid_charge_enabled"]
if self.control_mode == "vpp"
else [
"get_charging_power_rate",
"get_discharging_power_rate",
"grid_charge_enabled",
"get_charge_stop_soc",
"get_discharge_stop_soc",
]
)
health_check = perform_health_check(
component_name="Battery Control",
description="Controls battery charging and discharging schedule",
is_required=True,
controller=controller,
all_methods=all_methods,
)
required_keys = (
[
"growatt_vpp_status",
"growatt_vpp_remote_control",
"growatt_vpp_allow_ac_charging",
"growatt_vpp_time",
"growatt_vpp_power",
]
if self.control_mode == "vpp"
else [
"tou_time_1_enabled",
"tou_time_1_begin",
"tou_time_1_end",
"tou_time_1_mode",
"tou_time_1_update",
]
)
entity_label = "VPP Entity" if self.control_mode == "vpp" else "TOU Entity"
for key in required_keys:
entity_id = controller.sensors.get(key, "")
if entity_id:
status, error = "OK", None
else:
status, error = "ERROR", "Not configured — re-run setup wizard"
health_check["checks"].append(
{
"name": f"{entity_label}: {key}",
"key": key,
"method_name": None,
"entity_id": entity_id or "Not configured",
"status": status,
"rawValue": None,
"displayValue": entity_id or "Not configured",
"error": error,
}
)
# Re-evaluate overall status including the mode-specific checks
has_error = any(c["status"] == "ERROR" for c in health_check["checks"])
has_warning = any(c["status"] == "WARNING" for c in health_check["checks"])
if has_error:
health_check["status"] = "ERROR"
elif has_warning:
health_check["status"] = "WARNING"
return [health_check]