@pookey

Opening an issue for a better place to discuss the topic rather than email/PRs, as I can attached logs etc here easier!

On a MIN inverter, when in the default mode 'on grid mode (load first), excess power goes to the battery. However, BESS's 'idle' mode assumes it goes to the grid. This causes the battery to charge far quicker than modelled, leading so solar slipping when you have an over sized array.

Screenshot and debug log attached. Ref #17