Device info
Scan result from micro-ebusd (firmware 20260317, ESP32-C6):
18: *fail, Vaillant;V32;121;9802, MF fail
- eBUS address: 18 (hex: 12)
-
- Manufacturer: Vaillant
-
-
- Device type: V32 (VR32 zone module, circuit 2 — CV boiler)
-
-
-
-
- SW version: 121
-
-
-
-
-
-
- HW version: 9802
-
-
-
System context
- Vaillant heat pump (HMU00;902;5103, loaded 508.hmu.HW5103) at address 08
-
- Vaillant CTLV2 controller (514;1104, loaded 515.ctlv2) at address 15
-
-
- Vaillant VR_70 mixer (109;2903, loaded 552.vr_70) at address 52
-
-
-
-
- Vaillant VWZIO zone I/O (202;103, loaded 576.vwz) at address 76
-
-
-
-
-
-
- V32 at address 18 — no definition found
-
-
-
micro-ebusd behaviour
reload -d 12 returns reload messages but the device stays as *fail — confirmed no CDN entry exists for this firmware ID.
Direct read attempts via hex 1208070400 result in ERR: read timeout — the V32 does not respond to direct read commands.
Passive messages observed
The following unknown messages were passively received from the V32 (seen in REPL):
ebusd: received unknown 1008b5110100 / 09ef0109000108000000
ebusd: received unknown 7108b51a0304f632 / 0ef607c0cfc07b3c00b01b20000000
Request
Please add a definition file for V32;121;9802 (address 12 hex / 18 decimal). The existing 08.v3x.csv may be a starting point — this device likely needs a 12.v3x.csv or similar entry on the CDN keyed to address 12.
Happy to provide additional raw bus captures if needed.