Skip to content

Request support for Alsavo heat pump #2884

Open
@SvLogchem

Description

@SvLogchem

Log message

2025-01-31 11:11:12.764 WARNING (MainThread) [custom_components.tuya_local.config_flow] Device matches stepuptech_solar_inverter_v2 with quality of 24%. DPS: {"updated_at": 1738318270.3997474, "1": true, "2": "heating", "4": 25, "103": 20, "104": 0, "105": 12, "106": -4, "107": 15, "108": 40, "109": 7, "110": "COOL", "111": 0, "112": 0, "113": 226, "114": -420, "115": 225, "116": 300, "117": 54, "118": 45, "119": 220, "120": 142, "121": 400, "122": 0, "123": 0, "124": 0, "125": 3, "127": 0, "129": 0, "130": 317, "131": 233, "132": 0, "133": 0, "135": 0, "136": "para_p"}
2025-01-31 11:11:12.764 WARNING (MainThread) [custom_components.tuya_local.config_flow] Include the previous log messages with any new device request to https://github.com/make-all/tuya-local/issues/

Product ID

tf8ykxqlvmhbh3to

Product Name

Alsavo heat pump

DPS information

{
  "result": {
    "properties": [
      {
        "code": "switch",
        "custom_name": "On/Off",
        "dp_id": 1,
        "time": 1738266238578,
        "type": "bool",
        "value": true
      },
      {
        "code": "mode",
        "custom_name": "Heat pump mode",
        "dp_id": 2,
        "time": 1738256089445,
        "type": "enum",
        "value": "heating"
      },
      {
        "code": "temp_set",
        "custom_name": "Temprature setpoint",
        "dp_id": 4,
        "time": 1738303582795,
        "type": "value",
        "value": 26
      },
      {
        "code": "SET_TANK_TEMP",
        "custom_name": "DHW water tank setpoint",
        "dp_id": 103,
        "time": 1738252316140,
        "type": "value",
        "value": 20
      },
      {
        "code": "fault_num",
        "custom_name": "",
        "dp_id": 104,
        "time": 1738256089481,
        "type": "value",
        "value": 0
      },
      {
        "code": "SET_COOL_TEMP",
        "custom_name": "Cooling setpoint",
        "dp_id": 105,
        "time": 1738303215593,
        "type": "value",
        "value": 12
      },
      {
        "code": "SET_DEFIN_TEMP",
        "custom_name": "Start defrost temp",
        "dp_id": 106,
        "time": 1738252395377,
        "type": "value",
        "value": -4
      },
      {
        "code": "SET_DEFOUT_TEMP",
        "custom_name": "stop defrost temp",
        "dp_id": 107,
        "time": 1738252316209,
        "type": "value",
        "value": 15
      },
      {
        "code": "SET_DEF_LOOPTIME",
        "custom_name": "Defrost cycle",
        "dp_id": 108,
        "time": 1738252316227,
        "type": "value",
        "value": 40
      },
      {
        "code": "SET_DEF_MAXTIME",
        "custom_name": "Max defrost time",
        "dp_id": 109,
        "time": 1738256061484,
        "type": "value",
        "value": 7
      },
      {
        "code": "RUN_MODE",
        "custom_name": "Cool or Heat",
        "dp_id": 110,
        "time": 1738256167674,
        "type": "enum",
        "value": "COOL"
      },
      {
        "code": "RUN_FREQUENT",
        "custom_name": "Frequent of heat pump in hz",
        "dp_id": 111,
        "time": 1738316392404,
        "type": "value",
        "value": 43
      },
      {
        "code": "RUN_CURRENT",
        "custom_name": "used current in A",
        "dp_id": 112,
        "time": 1738316396419,
        "type": "value",
        "value": 0
      },
      {
        "code": "WATER_BACK_TEMP",
        "custom_name": "Return temp",
        "dp_id": 113,
        "time": 1738317853504,
        "type": "value",
        "value": 233
      },
      {
        "code": "WATER_TANK_TEMP",
        "custom_name": "Water tank temp",
        "dp_id": 114,
        "time": 1738252316340,
        "type": "value",
        "value": -420
      },
      {
        "code": "WATER_OUT_TEMP",
        "custom_name": "Water outlet temp",
        "dp_id": 115,
        "time": 1738317629181,
        "type": "value",
        "value": 236
      },
      {
        "code": "SYS_PQ_TEMP",
        "custom_name": "",
        "dp_id": 116,
        "time": 1738317542161,
        "type": "value",
        "value": 330
      },
      {
        "code": "OUT_TEMP",
        "custom_name": "Outside temprature",
        "dp_id": 117,
        "time": 1738317856565,
        "type": "value",
        "value": 49
      },
      {
        "code": "SYS_PG_TEMP",
        "custom_name": "",
        "dp_id": 118,
        "time": 1738317872576,
        "type": "value",
        "value": 41
      },
      {
        "code": "SYS_BACK_TEMP",
        "custom_name": "",
        "dp_id": 119,
        "time": 1738317860603,
        "type": "value",
        "value": 205
      },
      {
        "code": "SYS_JIEL_TEMP",
        "custom_name": "",
        "dp_id": 120,
        "time": 1738317782498,
        "type": "value",
        "value": 145
      },
      {
        "code": "MIAN_EVI_STEP",
        "custom_name": "",
        "dp_id": 121,
        "time": 1738315218667,
        "type": "value",
        "value": 400
      },
      {
        "code": "PROTECT_FLAG",
        "custom_name": "",
        "dp_id": 122,
        "time": 1738252316503,
        "type": "value",
        "value": 0
      },
      {
        "code": "TRAGE_FREQUENT",
        "custom_name": "Target frequint of heat pump",
        "dp_id": 123,
        "time": 1738315217663,
        "type": "value",
        "value": 0
      },
      {
        "code": "EVI_STEP",
        "custom_name": "",
        "dp_id": 124,
        "time": 1738314706925,
        "type": "value",
        "value": 60
      },
      {
        "code": "IPM_TEMP",
        "custom_name": "",
        "dp_id": 125,
        "time": 1738317847618,
        "type": "value",
        "value": 3
      },
      {
        "code": "pro_flag1",
        "custom_name": "",
        "dp_id": 127,
        "time": 1738256089850,
        "type": "value",
        "value": 0
      },
      {
        "code": "pro_flag2",
        "custom_name": "",
        "dp_id": 129,
        "time": 1738252316603,
        "type": "value",
        "value": 0
      },
      {
        "code": "DCBUS_VOL",
        "custom_name": "",
        "dp_id": 130,
        "time": 1738317832679,
        "type": "value",
        "value": 317
      },
      {
        "code": "ACIN_VOL",
        "custom_name": "",
        "dp_id": 131,
        "time": 1738317760551,
        "type": "value",
        "value": 232
      },
      {
        "code": "pro_flag3",
        "custom_name": "",
        "dp_id": 132,
        "time": 1738252316666,
        "type": "value",
        "value": 0
      },
      {
        "code": "pro_flag4",
        "custom_name": "",
        "dp_id": 133,
        "time": 1738252316686,
        "type": "value",
        "value": 0
      },
      {
        "code": "datebuf_address",
        "custom_name": "",
        "dp_id": 134,
        "time": 1738162627106,
        "type": "value",
        "value": 0
      },
      {
        "code": "datebuf_value",
        "custom_name": "",
        "dp_id": 135,
        "time": 1738252316705,
        "type": "value",
        "value": 0
      },
      {
        "code": "para_type",
        "custom_name": "",
        "dp_id": 136,
        "time": 1738252316723,
        "type": "enum",
        "value": "para_p"
      }
    ]
  },
  "success": true,
  "t": 1738317876631,
  "tid": "c6e96aaadfba11ef9e609e9247cde4aa"
}

Information about how the device functions

I tried to add the custom names as explanation. for help or quistions i'm always avadible.