I'm getting the following error after moving the IMU:
python3 accel_integration.py
Starting Data Acquisition
Start Moving IMU...
Data Acquisition Stopped
Traceback (most recent call last):
File "accel_integration.py", line 189, in <module>
imu_integrator()
File "accel_integration.py", line 128, in imu_integrator
b_filt,a_filt = signal.butter(4,5,'low',fs=Fs_approx)
File "/home/pi/imu_project/venv/lib/python3.7/site-packages/scipy/signal/filter_design.py", line 2957, in butter
output=output, ftype='butter', fs=fs)
File "/home/pi/imu_project/venv/lib/python3.7/site-packages/scipy/signal/filter_design.py", line 2423, in iirfilter
"must be 0 < Wn < fs/2 (fs={} -> fs/2={})".format(fs, fs/2))
ValueError: Digital filter critical frequencies must be 0 < Wn < fs/2 (fs=6.0 -> fs/2=3.0)
Any idea why this happens?