classdef tBehPrepUnit < sltest.TestCase
% tBehPrepUnit - Behavioral tests for the BehPrepUnit component model.
%
% Ports (fixed simulation order):
% Inports: supply_bps, enable
% Outports: outflow_bps, demand_bps
properties (Constant)
ModelName = 'BehPrepUnit'
PrepRateBph = 100 % must match model argument default
end
methods (Test)
function capacityLimitedSteadyState(testCase)
% Abundant supply should saturate outflow at PrepRate/3600
% once the first-order lag settles.
stopTime = 1200;
hugeSupply = 1.0;
extInput = sprintf('[0 %g 1; %g %g 1]', hugeSupply, stopTime, hugeSupply);
out = testCase.runModel(extInput, stopTime);
outflow = out.yout{1}.Values.Data;
demand = out.yout{2}.Values.Data;
capacityBps = tBehPrepUnit.PrepRateBph / 3600;
testCase.verifyEqual(outflow(end), capacityBps, 'RelTol', 0.02);
testCase.verifyEqual(demand(end), capacityBps, 'RelTol', 0.02);
end
function supplyLimitedSteadyState(testCase)
% A supply below rated capacity should pass through at
% steady state (lag settles to the input value).
stopTime = 1200;
scarceSupply = 0.01;
extInput = sprintf('[0 %g 1; %g %g 1]', scarceSupply, stopTime, scarceSupply);
out = testCase.runModel(extInput, stopTime);
outflow = out.yout{1}.Values.Data;
testCase.verifyEqual(outflow(end), scarceSupply, 'RelTol', 0.02);
end
function disabledUnitProducesNothing(testCase)
% enable=0 should zero both outflow and demand regardless of
% supply.
stopTime = 600;
extInput = sprintf('[0 1 0; %g 1 0]', stopTime);
out = testCase.runModel(extInput, stopTime);
outflow = out.yout{1}.Values.Data;
demand = out.yout{2}.Values.Data;
testCase.verifyEqual(outflow(end), 0, 'AbsTol', 1e-6);
testCase.verifyEqual(demand(end), 0, 'AbsTol', 1e-9);
end
end
methods (Static, Access = private)
function out = runModel(extInput, stopTime, varargin)
% Build and run a SimulationInput for BehPrepUnit.
% varargin is a name/value list of model-argument overrides.
in = Simulink.SimulationInput(tBehPrepUnit.ModelName);
in = in.setModelParameter('LoadExternalInput', 'on', ...
'ExternalInput', extInput, ...
'StopTime', num2str(stopTime), ...
'SaveOutput', 'on', ...
'SaveFormat', 'Dataset');
for k = 1:2:numel(varargin)
in = in.setVariable(varargin{k}, varargin{k+1}, 'Workspace', tBehPrepUnit.ModelName);
end
simOut = sim(in);
out = simOut;
end
end
end